<strong>Advanced</strong> <strong>Configuration</strong> <strong>and</strong> <strong>Power</strong> <strong>Interface</strong> <strong>Specification</strong><br />

Example:<br />

// Fan Control is defined as follows:<br />

// Speed 1 (Fan is Off): Acoustic Limit 1, <strong>Power</strong> Limit 1, = 95C<br />

// _SCP Notifies the platform the current cooling mode.<br />

// Arg0 = Mode<br />

// 0 - Active cooling<br />

// 1 - Passive cooling<br />

// Arg1 = Acoustic Limit<br />

// 1 = No acoustic tolerance<br />

// ...<br />

// 5 = maximum acoustic tolerance<br />

// Arg2 = <strong>Power</strong> Limit<br />

// 1 = No power may be used to cool<br />

// ...<br />

// 5 = maximum power may be used to cool<br />

Method(_SCP,3,Serialized)<br />

{<br />

// Store the Cooling Mode in NVS <strong>and</strong> use as needed in<br />

// the rest of the ASL Code.<br />

Store(Arg0, CTYP)<br />

// Set PSVT to account for a Legacy OS that does not pass<br />

// in either the acoustic limit or <strong>Power</strong> Limit.<br />

If(Arg0)<br />

{<br />

Store(60,PSVT)<br />

}<br />

Else<br />

{<br />

Store(97,PSVT)<br />

}<br />

If (CondRefOf (_OSI,Local0))<br />

{<br />

If (\_OSI ("3.0 _SCP Extensions"))<br />

{<br />

// Determine <strong>Power</strong> Limit.<br />

//<br />

// NOTE1: PSVT = Passive Cooling Trip Point stored<br />

// in NVS in Celsius.<br />

//<br />

// NOTE2: 4 Active Cooling Trips Points correspond to 5<br />

// unique <strong>Power</strong> Limit regions <strong>and</strong> 5 unique acoustic limit<br />

// regions.<br />

616 April, 2015 Version 6.0