<strong>Power</strong> Source <strong>and</strong> <strong>Power</strong> Meter Devices<br />

10.4.8 _PMD (<strong>Power</strong> Metered Devices)<br />

This object evaluates to a package of device names. Each name corresponds to a device in the ACPI<br />

namespace that is being measured by the power meter device. The measurement reported by the<br />

power meter is roughly correspondent to the total power draw of all the devices returned.<br />

If this control method is present, the package needs to contain at least 1 device. On a system that<br />

supports power metering, a system power meter that measures the power draw of the entire system<br />

should always be present <strong>and</strong> have a _PMD that contains \_SB as its sole entry.<br />

Arguments:<br />

None<br />

Return Value:<br />

A variable-length Package consisting of references to devices being measured by the power meter.<br />

Package {<br />

<strong>Power</strong> Meter[0]<br />

<strong>Power</strong> Meter[1]<br />

...<br />

<strong>Power</strong> Meter[n]<br />

}<br />

// NamePath<br />

// NamePath<br />

// NamePath<br />

10.5 Example: <strong>Power</strong> Source <strong>and</strong> <strong>Power</strong> Meter Namespace<br />

Figure 10-64 below shows the ACPI namespace for a computer with a power meter, AC adapter <strong>and</strong><br />

two batteries associated with a docking station which itself has an AC adapter.<br />

d<br />

Version 6.0 591