27.10.2015 Views

Advanced Configuration and Power Interface Specification

ACPI_6.0

ACPI_6.0

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Advanced</strong> <strong>Configuration</strong> <strong>and</strong> <strong>Power</strong> <strong>Interface</strong> <strong>Specification</strong><br />

Field Format Description<br />

Design capacity<br />

of Warning<br />

Design Capacity<br />

of Low<br />

Cycle Count<br />

Measurement<br />

Accuracy<br />

Max Sampling<br />

Time<br />

Min Sampling<br />

Time<br />

Max Averaging<br />

Interval<br />

Min Averaging<br />

Interval<br />

Battery Capacity<br />

Granularity 1<br />

Battery Capacity<br />

Granularity 2<br />

Model Number<br />

Integer<br />

(DWORD)<br />

Integer<br />

(DWORD)<br />

Integer<br />

(DWORD)<br />

Integer<br />

(DWORD)<br />

Integer<br />

(DWORD)<br />

Integer<br />

(DWORD)<br />

Integer<br />

(DWORD)<br />

Integer<br />

(DWORD)<br />

Integer<br />

(DWORD)<br />

Integer<br />

(DWORD)<br />

String<br />

(ASCIIZ)<br />

OEM-designed battery warning capacity. See Section 3.9.4, “Low<br />

Battery Levels.”<br />

• 0x000000000 – 0x7FFFFFFF in [mWh] or [mAh]<br />

OEM-designed low battery capacity. See Section 3.9.4, “Low Battery<br />

Levels.”<br />

• 0x000000000 – 0x7FFFFFFF in [mWh] or [mAh]<br />

The number of cycles the battery has experienced. A cycle is defined as:<br />

An amount of discharge approximately equal to the value of Design<br />

Capacity.<br />

• 0x000000000 – 0xFFFFFFFE<br />

• 0xFFFFFFFF – Unknown cycle count<br />

The accuracy of the battery capacity measurement, in thous<strong>and</strong>th of a<br />

percent. (0% - 100.000%) For example, The value 80000 would mean<br />

80% accuracy.<br />

The sampling time is the duration between two consecutive<br />

measurements of the battery’s capacities specified in _BST, such as<br />

present rate <strong>and</strong> remaining capacity. If the OSPM makes two succeeding<br />

readings through _BST beyond the duration, two different results will be<br />

returned.<br />

The Max Sampling Time is the maximum sampling time the battery can<br />

support, in milliseconds.<br />

0xFFFFFFFF is returned if the information is unavailable.<br />

The Min Sampling Time is the minimum sampling time the battery can<br />

support, in milliseconds.<br />

0xFFFFFFFF is returned if the information is unavailable.<br />

The Average Interval is the length of time (in milliseconds) within which<br />

the battery averages the capacity measurements specified in _BST, such<br />

as remaining capacity <strong>and</strong> present rate.<br />

The Sampling time specifies the frequency of measurements, <strong>and</strong> the<br />

average interval specifies the width of the time window of every<br />

measurement.<br />

This field indicates the maximum Average Interval that the battery<br />

supports.<br />

This field indicates the minimum Average Interval that the battery<br />

supports<br />

Battery capacity granularity between low <strong>and</strong> warning in [mAh] or [mWh].<br />

That is, this is the smallest increment in capacity that the battery is<br />

capable of measuring. See note below for more details<br />

Battery capacity granularity between warning <strong>and</strong> Full in [mAh] or [mWh].<br />

That is, this is the smallest increment in capacity that the battery is<br />

capable of measuring. This may be a different value than Battery<br />

Capacity Granularity 1 to accommodate systems where the granularity<br />

accuracy may change depending on the battery level. See note below for<br />

more details.<br />

OEM-specific Control Method Battery model number<br />

574 April, 2015 Version 6.0