Device <strong>Configuration</strong><br />

Field<br />

Byte<br />

Length<br />

Byte<br />

Offset<br />

Description<br />

Signature 4 0 ‘SLIT’.<br />

Length 4 4 60<br />

Revision 1 8 1<br />

Checksum 1 9 Entire table must sum to zero.<br />

OEMID 6 10 OEM ID.<br />

OEM Table ID 8 16 For the System Locality Information Table, the table ID is<br />

the manufacturer model ID.<br />

OEM Revision 4 24 OEM revision of System Locality Information Table for<br />

supplied OEM Table ID.<br />

Creator ID 4 28 Vendor ID of utility that created the table. For the DSDT,<br />

RSDT, SSDT, <strong>and</strong> PSDT tables, this is the ID for the ASL<br />

Compiler.<br />

Creator Revision 4 32 Revision of utility that created the table. For the DSDT,<br />

RSDT, SSDT, <strong>and</strong> PSDT tables, this is the revision for the<br />

ASL Compiler.<br />

Number of System 8 36 4<br />

Localities<br />

Entry[0][0] 1 44 10<br />

Entry[0][1] 1 45 15<br />

Entry[0][2] 1 46 20<br />

Entry[0][3] 1 47 18<br />

Entry[1][0] 1 48 15<br />

Entry[1][1] 1 49 10<br />

Entry[1][2] 1 50 16<br />

Entry[1][3] 1 51 24<br />

Entry[2][0] 1 52 20<br />

Entry[2][1] 1 53 16<br />

Entry[2][2] 1 54 10<br />

Entry[2][3] 1 55 12<br />

Entry[3][0] 1 56 18<br />

Entry[3][1] 1 57 24<br />

Entry[3][2] 1 58 12<br />

Entry[3][3] 1 59 10<br />

If a new node, “Node 4”, is added, then Table 6-183 represents the updated system’s NUMA relative<br />

distances of proximity domains.<br />

Table 6-183 Example Relative Distances Between Proximity Domains - 5 Node<br />

Proximity Domain 0 1 2 3 4<br />

0 10 15 20 18 17<br />