Table 5-143 Control Method Battery Device Notification Values<br />

Hex value<br />

0x80<br />

0x81<br />

0x82<br />

0x83-0xBF<br />

Description<br />

Battery Status Changed. Used to notify OSPM that the Control Method Battery device<br />

status has changed.<br />

Battery Information Changed. Used to notify OSPM that the Control Method Battery device<br />

information has changed. This only occurs when a battery is replaced.<br />

Battery Maintenance Data Status Flags Check. Used to notify OSPM that the Control<br />

Method Battery device battery maintenance data status flags should be checked.<br />

Reserved.<br />

Table 5-144 <strong>Power</strong> Source Object Notification Values<br />

Hex value<br />

0x80<br />

0x81<br />

0x82-0xBF<br />

Description<br />

<strong>Power</strong> Source Status Changed. Used to notify OSPM that the power source status has<br />

changed.<br />

<strong>Power</strong> Source Information Changed. Used to notify OSPM that the power source<br />

information has changed.<br />

Reserved.<br />

Table 5-145 Thermal Zone Object Notification Values<br />

Hex value<br />

0x80<br />

0x81<br />

0x82<br />

0x83<br />

0x84-0xBF<br />

Description<br />

Thermal Zone Status Changed. Used to notify OSPM that the thermal zone temperature<br />

has changed.<br />

Thermal Zone Trip points Changed. Used to notify OSPM that the thermal zone trip points<br />

have changed.<br />

Device Lists Changed. Used to notify OSPM that the thermal zone device lists (_ALx,<br />

_PSL, _TZD) have changed.<br />

Thermal / Active Cooling Relationship Table Changed. Used to notify OSPM that values<br />

in the either the thermal relationship table or the active cooling relationship table have<br />

changed.<br />

Reserved.<br />

Table 5-146 Control Method <strong>Power</strong> Button Notification Values<br />

Hex value<br />

0x80<br />

0x81-0xBF<br />

Description<br />

S0 <strong>Power</strong> Button Pressed. Used to notify OSPM that the power button has been pressed<br />

while the system is in the S0 state. Notice that when the button is pressed while the system is<br />

in the S1-S4 state, a Device Wake notification must be issued instead.<br />

Reserved.<br />

252 April, 2015 Version 6.0