<strong>Advanced</strong> <strong>Configuration</strong> <strong>and</strong> <strong>Power</strong> <strong>Interface</strong> <strong>Specification</strong><br />

former case, while allowing the flexibility for the latter as well. These structures must be organized<br />

in ascending order of the proximity domain enumerations. All proximity domains within the<br />

Maximum Number of Proximity Domains reported in the MSCT must be covered by one of these<br />

structures.<br />

Table 5-82 Maximum Proximity Domain Information Structure<br />

Field<br />

Byte<br />

Length<br />

Byte<br />

Offset<br />

Revision 1 0 1<br />

Length 1 1 22<br />

Proximity Domain<br />

Range (low)<br />

Proximity Domain<br />

Range (high)<br />

Maximum<br />

Processor<br />

Capacity<br />

Maximum Memory<br />

Capacity<br />

Description<br />

4 2 The starting proximity domain for the proximity domain range that<br />

this structure is providing information.<br />

4 6 The ending proximity domain for the proximity domain range that<br />

this structure is providing information.<br />

4 10 The Maximum Processor Capacity of each of the Proximity<br />

Domains specified in the range. A value of 0 means that the<br />

proximity domains do not contain processors. This field must be >=<br />

the number of processor entries for the domain in the SRAT.<br />

8 14 The Maximum Memory Capacity (size in bytes) of the Proximity<br />

Domains specified in the range. A value of 0 means that the<br />

proximity domains do not contain memory.<br />

5.2.20 ACPI RAS FeatureTable (RASF)<br />

The following table describes structure of ACPI RAS Feature Table.<br />

Table 5-83 RASF Table format<br />

Field<br />

Byte Byte Offset Description<br />

Length<br />

Header<br />

Signature 4 0 ‘RASF’ is Signature for RAS Feature Table<br />

Length 4 4 Length in bytes for entire RASF. The length<br />

implies the number of Entry fields at the end of<br />

the table<br />

Revision 1 8 1<br />

Checksum 1 9 Entire table must sum to zero<br />

OEMID 6 10 OEM ID<br />

OEM Table ID 8 16 The table ID is the manufacturer model ID<br />

OEM Revision 4 24 OEM revision of table for supplied OEM Table ID<br />

Creator ID 4 28 Vendor ID of utility that created the table<br />

Creator Revision 4 32 Revision of utility that created the table<br />

RASF Specific Entries<br />