9 280<br />
DESIGO PX<br />
<strong>Extension</strong> <strong>module</strong><br />
<strong>for</strong> <strong>KNX</strong> / <strong>EIB</strong><br />
<strong>for</strong> <strong>KNX</strong> / <strong>EIB</strong> integration<br />
<strong>PXA30</strong>-<strong>K11</strong><br />
• Integration of <strong>KNX</strong> / <strong>EIB</strong> subsystems at the automation level of the DESIGO<br />
building automation and control system<br />
• Plugs into the modular automation station type PXC...-U<br />
Functions<br />
• Integration of max. 45 RXB… room controllers (S-mode or polling)<br />
• Integration of max. 2000 data points from <strong>KNX</strong> / <strong>EIB</strong> 3rd party systems (S-mode)<br />
Types<br />
<strong>PXA30</strong>-<strong>K11</strong><br />
<strong>Extension</strong> <strong>module</strong><br />
Compatibility<br />
The <strong>module</strong> is plugged into a PXC64-U or PXC128-U automation station.<br />
CM1N9280en_02<br />
18 May 2009 Building Technologies
Ordering<br />
When ordering, please specify the quantity, product name and type code.<br />
Example:<br />
30 <strong>Extension</strong> <strong>module</strong>s <strong>PXA30</strong>-<strong>K11</strong><br />
Design<br />
• Two-part snap-together housing (plastic)<br />
• Cover <strong>for</strong> contact protection<br />
• PCB with electronic components<br />
• Two-pole <strong>EIB</strong>/<strong>KNX</strong> connection terminals<br />
• RJ45 service socket<br />
• Service pin<br />
9280Z01<br />
Mounting<br />
The extension <strong>module</strong> is plugged into the PXC..-U modular automation station.<br />
It is important to follow the instructions supplied with the device, in particular:<br />
• Avoid touching the connector pins (ESD precautions)<br />
• Push the <strong>module</strong> firmly into position (1.5 mm) and check that it is securely in place<br />
so that the fine contact pins interlock properly.<br />
2<br />
1<br />
3<br />
3<br />
1 Plug-in unit<br />
2 Device base<br />
3 <strong>Extension</strong> <strong>module</strong><br />
9280Z02<br />
2/4<br />
<strong>Siemens</strong> <strong>PXA30</strong>-<strong>K11</strong> – <strong>Extension</strong> <strong>module</strong> <strong>for</strong> <strong>KNX</strong> / <strong>EIB</strong> CM1N9280en_02<br />
Building Technologies 18 May 2009
Commissioning<br />
For integration operation the corresponding firmware must be loaded into the PXC...-U<br />
automation station.<br />
Disposal<br />
The device includes electrical and electronic components and must not be disposed of<br />
as domestic waste.<br />
Current local legislation must be observed.<br />
Technical data<br />
Elements of the user interface Service pin<br />
Programming mode<br />
<strong>KNX</strong> / <strong>EIB</strong> interface<br />
Stranded or solid conductors,<br />
2 x 1.0 mm 2<br />
<strong>KNX</strong> / <strong>EIB</strong> bus Interface type <strong>KNX</strong> / <strong>EIB</strong> (electrically isolated)<br />
Transceiver<br />
TP-UART<br />
Bus current<br />
5 mA<br />
Baud rate<br />
9.6 kbit/s<br />
Bus topology, bus termination<br />
Refer to <strong>KNX</strong> / <strong>EIB</strong> manual<br />
Service interface<br />
RJ45<br />
Housing<br />
Protection standard to EN 60529 IP 30<br />
protection standard<br />
Protection class Insulation protection class II<br />
Ambient conditions Normal operation Class 3K5 to IEC 721<br />
Temperature 0 ... 50 °C<br />
Humidity<br />
< 85 % rh<br />
Transport Class 2K3 to IEC 721<br />
Temperature – 25 ... 65 °C<br />
Humidity<br />
< 95 % rh<br />
Industry standards<br />
Product safety<br />
Automatic electronic controls <strong>for</strong><br />
household and similar use EN 60730-1<br />
Special requirements <strong>for</strong> energy controllers EN 60730-2-11<br />
Electromagnetic compatibility<br />
Interference immunity<br />
EN 61000-6-2 (Industry)<br />
Emitted interference<br />
EN 61000-6-3 (Residential)<br />
Meets the requirements <strong>for</strong> CE marking:<br />
EMC Directive<br />
2004/108/EG<br />
Dimensions<br />
See “Dimensions”<br />
Weight Excluding packaging 75 g<br />
With packaging<br />
95 g<br />
<strong>Siemens</strong> <strong>PXA30</strong>-<strong>K11</strong> – <strong>Extension</strong> <strong>module</strong> <strong>for</strong> <strong>KNX</strong> / <strong>EIB</strong> CM1N9280en_02<br />
Building Technologies 18 May 2009<br />
3/4
Connections<br />
Standard RJ45 socket<br />
<strong>for</strong> service<br />
87654321<br />
9280Z03<br />
1 <strong>KNX</strong> data cable (CE+)<br />
2 <strong>KNX</strong> data cable (CE–)<br />
3 Not used<br />
4 Not used<br />
5 Not used<br />
6 Not used<br />
7 Not used<br />
8 Not used<br />
<strong>KNX</strong> / <strong>EIB</strong>-interface<br />
9280Z05<br />
+ <strong>KNX</strong> data cable (CE+)<br />
– <strong>KNX</strong> data cable (CE–)<br />
Dimensions<br />
Dimensions in mm<br />
9280M01<br />
111<br />
62 33<br />
28<br />
4/4<br />
© 2004 – 2009 <strong>Siemens</strong> Switzerland Ltd. Subject to alteration<br />
<strong>Siemens</strong> <strong>PXA30</strong>-<strong>K11</strong> – <strong>Extension</strong> <strong>module</strong> <strong>for</strong> <strong>KNX</strong> / <strong>EIB</strong> CM1N9280en_02<br />
Building Technologies 18 May 2009