STUDENT HANDOUT<br />
DEMYSTIFYING HAZMAT CHEMISTRY<br />
Flammability<br />
When plotting the flammability risk on a hazard ladder, we generally look at the concentration of<br />
a gas or vapor in air, just as we do when plotting toxicity. The most important value is the Lower<br />
Explosive Limit (LEL). Below the LEL, vapors are too lean to burn. At the other end of the scale is<br />
the Upper Explosive Limit (UEL). Above this concentration, vapors are too rich to burn. However,<br />
from the LEL to the UEL, ignition is possible. This is known as the flammable range.<br />
Flammable Range<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Only atmospheres that are well below the LEL are safe to enter. Many agencies have SOPs that<br />
prohibit working in an atmosphere greater than 10% of the LEL. (That’s 10% of the LEL, not a<br />
10% contaminant concentration in the atmosphere.) In part, this comes from OSHA regulations<br />
that prohibit working in confined spaces with more than 10% of the LEL. However, when the environment<br />
does not meet the definition of a confined space, the Environmental Protection Agency’s<br />
guidelines suggest that hazardous materials technicians can keep working up to 25% of the LEL<br />
if they’re cautious and use continuous monitoring. Both limits (10% and 25%) still leave a good<br />
margin for error to guard against everything from fluctuations in the chemical concentration to<br />
defective monitors or errors in interpreting the meter readings.<br />
Although the vapors are too rich to burn above the UEL, you should not consider that to be a safe<br />
atmosphere since the vapor concentration may drop to within the flammable range during your<br />
emergency response operations.<br />
You can plot flammable range on a hazard ladder also. This gives you a clear visual representation<br />
of the flammability risk. The wider the flammable range, the greater the risk. Conversely,<br />
products with a narrow flammable range present less of a risk.<br />
Plotting LEL and UEL<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Continuing Challenge 2007 Page 13 © 2007 Firebelle Productions and CHES