Installation guide Wisotronic dialog 1-Channel CCU - Warema
Installation guide Wisotronic dialog 1-Channel CCU - Warema
Installation guide Wisotronic dialog 1-Channel CCU - Warema
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
7975k0/Ausgabe 11.2004<br />
WAREMA controls<br />
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
<strong>Installation</strong> <strong>guide</strong><br />
(Please save these Instructions for future use)<br />
Valid as from November 1, 2004<br />
932806B0•816758•7975k0•08.10.2004
General remarks<br />
General Remarks<br />
The publication of this manual<br />
supercedes all previous corresponding<br />
documentation.<br />
We reserve the right to make<br />
alterations in the interests of technical<br />
progress.<br />
Considerable care was taken in<br />
producing the text and graphics in this<br />
documentation but it is impossible to<br />
rule out errors completely.<br />
WAREMA provides you with a<br />
complete range of sun protection<br />
systems for windows, facades and<br />
glazed structures. Please contact the<br />
export department if you need any<br />
documentation on:<br />
– sun protection control systems<br />
– outside venetian blinds<br />
– inside venetian blinds<br />
– roller shutters<br />
– facade awnings<br />
– vertical awnings<br />
– markisolettes<br />
– conservatory awnings<br />
– articulated arm awnings<br />
– cassette awnings<br />
– basket awnings<br />
– Dutch canopy awning<br />
– insect screens<br />
– sun protections for roof windows<br />
– vertical louvre blinds<br />
– pleated blinds<br />
– roller blinds<br />
– black-out systems<br />
Safety Instructions<br />
Electrical installation work must be left<br />
strictly to qualified electricians. Only<br />
then is there any guarantee that your<br />
country´s statutory regulations are<br />
complied with and that the installation<br />
provisions of your local power supply<br />
company are properly observed. The<br />
user may be placed at serious risk if<br />
the equipment is wrongly installed.<br />
For further information please refer the<br />
the available user and installation<br />
<strong>guide</strong>s.<br />
Imprint<br />
WAREMA Renkhoff SE<br />
Hans-Wilhelm-Renkhoff Strasse 2<br />
D-97828 Marktheidenfeld/Main<br />
2<br />
Headquarter<br />
WAREMA Renkhoff SE<br />
Hans-Wilhelm-Renkhoff Strasse 2<br />
D-97828 Marktheidenfeld/Main<br />
P.o. box 13 55<br />
D-97822 Marktheidenfeld/Main<br />
Phone:+49 (0) 9391/20-0<br />
Fax: +49 (0) 9391/20-4299<br />
http://www.warema.com<br />
Sales Department (Sun protection<br />
control systems):<br />
Phone:+49 (0) 9391/20-3730;<br />
Fax: +49 (0) 9391/20-3739<br />
Application technique:<br />
Phone:+49 (0) 9391/20-6720;<br />
Fax: +49 (0) 9391/20-6729<br />
Service:<br />
Phone:+49 (0) 9391/20-6760;<br />
Fax: +49 (0) 9391/20-6769<br />
WAREMA and the WAREMA logo are trademarks of WAREMA Renkhoff SE.<br />
All other brand names or product names mentioned in this documentation are<br />
trade marks or registered trade marks of their respective owners.<br />
© 2004, WAREMA Renkhoff SE<br />
932806B0•816758•7975k0•08.10.2004
Table of contents<br />
1. General ................................................................................................................... 4<br />
2. For your safety ..................................................................................................... 5<br />
2.1 Pictogram and symbol explanations ................................................................ 5<br />
2.2 Usage to the intended purpose ....................................................................... 7<br />
2.3 Target group ..................................................................................................... 7<br />
2.4 Working safely ................................................................................................. 8<br />
2.5 Software version.............................................................................................. 8<br />
3. Mounting ............................................................................................................... 9<br />
3.1 Procedure ........................................................................................................ 9<br />
3.2 <strong>Installation</strong> ........................................................................................................... 10<br />
3.2.1 Flush-type mounting ................................................................................ 10<br />
3.2.2 Surface-type mounting ............................................................................. 10<br />
3.3 "Wind/Photo" sensor ...................................................................................... 12<br />
3.3.1 Allocation/alignment of the photo diodes................................................. 13<br />
3.4 "Photo" (180°) sensor ..................................................................................... 14<br />
3.5 "Rain" (capacitive) sensor .............................................................................. 14<br />
3.6 "Temperature" (outside) sensor ...................................................................... 15<br />
3.7 "Temperature" (inside) sensor 5 to 40°C ........................................................ 15<br />
3.8 "Temperature" (inside) sensor -25 to +75°C ................................................... 15<br />
3.9 Connecting sensors ....................................................................................... 16<br />
4. Connection-information ..................................................................................... 17<br />
4.1 Handling of the spring-load terminals ............................................................ 18<br />
4.2 Handling of the screw/clamp type terminals ................................................. 18<br />
5. Wiring diagrams .................................................................................................. 19<br />
5.1 "Wind/Photo" sensor ...................................................................................... 20<br />
5.2 "Photo" (180°) sensor ..................................................................................... 21<br />
5.3 „Rain“ (capacitive) sensor ............................................................................. 22<br />
5.4 „Temperature“ (outside) sensor .................................................................... 23<br />
5.5 „Temperature“ (inside) +5 to +40°C sensor ................................................. 24<br />
5.6 "Temperature" (inside) -25 to +75°C sensor ................................................... 25<br />
5.7 Connection of Power supply and control cables............................................ 26<br />
5.8 Connecting single drive ................................................................................. 27<br />
5.9 Mounting the contol panel ............................................................................. 28<br />
5.10 De-mounting the control panel ...................................................................... 28<br />
6. Commissioning .................................................................................................. 29<br />
6.1 Automatic presetting ..................................................................................... 29<br />
6.1.1 Password ................................................................................................. 29<br />
6.2 Changing the user language .......................................................................... 30<br />
6.3 Setting the product type ................................................................................ 31<br />
6.4 Allocating connected Sensors ....................................................................... 32<br />
6.5 Setting the time and date .............................................................................. 33<br />
7. Factory settings................................................................................................... 35<br />
8. Custom settings .................................................................................................. 37<br />
9. Technical data ...................................................................................................... 39<br />
10. User information ............................................................................................... 41<br />
11. Notes .................................................................................................................. 42<br />
932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 3
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
1. General<br />
4<br />
We reserve the right to carry out improvements<br />
With the <strong>Wisotronic</strong> <strong>dialog</strong> you now own a multifunctional sun protection control<br />
unit which can control various sun protection products (slat products, cloth<br />
products, roller shutters, etc.) intelligently in accordance with the respective<br />
weather conditions.<br />
You can either operate your sun protection products manually or leave the<br />
operation completely to the automatic control products. The <strong>Wisotronic</strong> <strong>dialog</strong><br />
protects your sunblind against harmful weather influences and offers extensive<br />
comfort and safety functions. The <strong>Wisotronic</strong> <strong>dialog</strong> can furthermore be operated<br />
via an EWFS radio remote control unit (1 or 8 channels), whereby the radio<br />
receiver is integrated in the control panel.<br />
The <strong>Wisotronic</strong> <strong>dialog</strong> evaluates the data for:<br />
® Wind,<br />
® Rain,<br />
® Brightness,<br />
® Internal and external temperature,<br />
and correspondingly controls the connected sun protection products, such as slat<br />
products (outside venetian blinds, internal venetian blinds), cloth products<br />
(awnings, pleated blinds), vertical venetian blinds, darkening units and roller<br />
shutters.<br />
932806B0•816758•7975k0•08.10.2004
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
2. For your safety<br />
2.1 Pictogram and symbol<br />
explanations<br />
We have developed, manufactured and tested the control system under<br />
observance of the fundamental safety requirements.<br />
Residual risks nevertheless remain!<br />
■ Therefore read these instructions before you install the control system.<br />
■ Please save these instructions for future use!<br />
The following warnings and notes which are intended to draw your attention to<br />
certain points can be applied to the control system itself or to the connected<br />
devices:<br />
Warning against dangerous electrical voltage!<br />
Electrostatic sensitive devices!<br />
Only for connection of the protective earth (PE) conductor!<br />
Only for connection of a shielded conductor!<br />
932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 5
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
6<br />
We reserve the right to carry out improvements<br />
Hierarchic warnings are used in these instructions.<br />
They are identified by a warning sign in the margin and graded hierarchically as<br />
follows:<br />
1. WARNING<br />
2. ATTENTION<br />
3. CAUTION<br />
WARNING<br />
ATTENTION<br />
CAUTION<br />
The term WARNING is used as a warning against immediate<br />
imminent danger.<br />
Death or serious injuries may result (damage to persons)<br />
The term ATTENTION is used as a warning against a possible<br />
imminent danger.<br />
Death, serious or minor injuries (damage to persons), damage to<br />
property or damage to the environment may result.<br />
The term CAUTION is used as an application<br />
recommendation.<br />
Damage to property may result from non-observance.<br />
In addition to the hierarchic warnings described above we use the following<br />
symbols:<br />
TIP<br />
■ This sign identifies<br />
This is used to mark text sections which contain additional<br />
explanations, information or hints.<br />
- Activities which you must carry out, or<br />
- Instructions which must be observed.<br />
932806B0•816758•7975k0•08.10.2004
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
2.2 Usage to the intended<br />
purpose<br />
2.3 Target group<br />
ATTENTION<br />
ATTENTION<br />
The control system allows the direct connection of a<br />
conventional sun protection drive. Alternatively several sun<br />
protection drives can be connected together via motor control<br />
units. Should you have any questions about connecting nonsun-protection<br />
devices, please obtain the approval of the<br />
manufacturer! The equipment is intended for the assembly in<br />
interiors.<br />
The approval of the manufacturer has to be obtained if the<br />
device is to be used to a purpose different to that described<br />
here. Usage which is not to the intended purpose can result in<br />
damage to the user or third parties as well as damage to the<br />
device itself, the connected devices or to the moving<br />
mechanical parts of the complete system.<br />
■ Therefore always use our product to the intended purpose only!<br />
These instructions are intended for persons who mount, wire or connect the<br />
<strong>Wisotronic</strong> <strong>dialog</strong> including all the required parts to the supply voltage. The user<br />
instructions (Art. No. 816757) are available for those persons who operate, set or<br />
commission the control system.<br />
ATTENTION<br />
Mounting, connection, commissioning or operation by<br />
persons who are not sufficiently qualified and informed can<br />
cause severe damage to the system or even damage to<br />
persons!<br />
■ Mounting and commissioning may therefore only be carried out by<br />
correspondingly trained specialists! This personnel must be able to recognize<br />
dangers which can be caused by the mechanical, electrical or electronic<br />
equipment!<br />
■ Persons who mount or connect the <strong>Wisotronic</strong> <strong>dialog</strong> must know and have<br />
understood the contents of these instructions.<br />
■ The <strong>Wisotronic</strong> <strong>dialog</strong> has been designed and constructed by us to be safe. All<br />
the necessary settings are carried out during the commissioning process. The<br />
system parameters only need to be modified if the behavior of the control<br />
system is to be adapted, a change has occurred at the sensor equipment or<br />
the <strong>Wisotronic</strong> <strong>dialog</strong> itself is replaced.<br />
ATTENTION<br />
States of danger, malfunctions and material damage to the<br />
system possible due to improperly executed mounting,<br />
connection, repair or maintenance work!<br />
■ Such work may only be carried out by the service department or by authorized<br />
qualified personnel!<br />
■ When carrying out maintenance or repair work only use such spare/<br />
replacement parts which are authorized by the system manufacturer.<br />
932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 7
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
2.4 Working safely<br />
2.5 Software version<br />
8<br />
We reserve the right to carry out improvements<br />
WARNING<br />
States of danger, malfunctions and material damage to the<br />
system due to the disconnection of connections during<br />
operation are possible!<br />
All the connections are required to ensure correct operation<br />
of the control system.<br />
■ Therefore always switch off the entire system before you connect or<br />
disconnect connecting lines.<br />
ATTENTION<br />
Danger to life and damage to property through sudden<br />
movements of mechanical units!<br />
■ If you want to carry out work at building facades at which motor-driven<br />
sunblinds are installed, switch off the sun protection system beforehand!<br />
Ensure that the system is secured sufficiently against unauthorized or<br />
unintentional activation.<br />
■ Ensure that suitable systems for protecting persons are used under all<br />
circumstances.<br />
■ Never place any objects in the area of movement of an automatically<br />
controlled mechanism (for example a ladder against a wall with articulated arm<br />
awning)!<br />
The following documents are available in addition to these instructions:<br />
® User <strong>guide</strong> Art. No.: 816757<br />
® Anschlusspläne für MSE, Netzteile und GA Art. 816 345 (German)<br />
These instructions were drawn up on the basis of the software version<br />
19531103<br />
Please refer to Section 8 of the user <strong>guide</strong> for further information about<br />
establishing the software version of your device.<br />
932806B0•816758•7975k0•08.10.2004
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
3. Mounting<br />
3.1 Procedure<br />
CAUTION<br />
States of danger and malfunctions possible!<br />
The <strong>Wisotronic</strong> <strong>dialog</strong> and its supplementary components<br />
may only be operated in a built-in state or at the specified<br />
mounting sites. If this is not observed, malfunctions or states<br />
of danger at the system are possible. Any claims to warranty<br />
or guarantee are definitely lost.<br />
Carry out the following points in the specified order:<br />
■ First specify at which points the individual components are to be mounted.<br />
Use the specifications in this section and in the data sheets of the sensors to<br />
this purpose.<br />
■ Then determine which cables are required to interconnect the components.<br />
Use the "Wiring diagrams" section to this purpose.<br />
■ Lay the required cables. Do not use cables with larger cross-sections than<br />
specified. It is best to use conduits to lay the motor cables.<br />
■ Mount and wire the individual components.<br />
■ Check the wiring before you switch on the supply voltage of the control<br />
system.<br />
■ Then carry out commissioning. Only then is the control system ready for use.<br />
The steps required for commissioning are described in detail in the "User<br />
<strong>guide</strong>" manual. Please refer to it.<br />
■ Check the correct direction of movement of the sunblind by operating the "Up"<br />
and "Down" buttons at the control system.<br />
Check the correct function of the connected sensors<br />
■ Check the measured value display of the temperature, humidity and<br />
brightness for plausible values.<br />
■ Check whether the wind speed display changes when the wind vane is<br />
turned.<br />
■ Activate the rain control (if sensor connected) and check whether the control<br />
system reacts to rain (wet the sensor area with water).<br />
■ Then adapt the behavior of the system to the ambient conditions and for<br />
special requirements. Also use the "User <strong>guide</strong>" to this purpose. Chapter 7 of<br />
this installation <strong>guide</strong> furthermore contains a table with all the available setting<br />
steps (parameters), their limits and the factory settings.<br />
■ If you have changed the factory settings, record the new values of the system<br />
in the table (Chapter 9) after you have completed all the work.<br />
ATTENTION<br />
Mount electrical devices so that they can be accessed easily!<br />
(VDE 0100)<br />
932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 9
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
3.2 <strong>Installation</strong><br />
3.2.1 Flush-type mounting<br />
3.2.2 Surface-type mounting<br />
10<br />
We reserve the right to carry out improvements<br />
The <strong>Wisotronic</strong> <strong>dialog</strong> is designed for installation in a flush-mounting box, a<br />
surface-mounting housing is also available. The device is to be mounted in a dry<br />
and easily accessible place. Under no circumstances may it mounted outdoors,<br />
may not be subjected to direct sun irradiation or may not be mounted directly over<br />
a radiator. After installation in the flush-mounted box the bottom plate of the<br />
supply unit must be flush with the wall. Otherwise the control panel may not latch<br />
in correctly. The flush-mounted box should therefore be embedded horizontally in<br />
the plaster.<br />
■ After the cables have been connected, the power unit is fastened in the flushmounted<br />
box with the enclosed screws. Note: Do not tighten the screws too<br />
much, because the bottom plate may be damaged! Ensure that no connecting<br />
cables are pinched during installation.<br />
Fig. 3-1: <strong>Installation</strong> in flush-mounted box<br />
■ Use the same procedure for the surface-mounted housing.<br />
Fig. 3-2: <strong>Installation</strong> in surface-mounted housing<br />
CAUTION<br />
Bottom plate<br />
Power unit<br />
Flushmounted<br />
box<br />
Use only the supplied screws to mount the bottom plate!<br />
Screw all the screws<br />
in completely until the screw heads are flush with the bottom<br />
plate.<br />
Otherwise short-circuits are possible when the control panel<br />
is clipped on!<br />
932806B0•816758•7975k0•08.10.2004
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
The radio receiver has been integrated into the control panel. The range of radio<br />
control systems is limited by the statutory regulations on radio systems and by<br />
structures. When planning the system ensure that the radio reception is<br />
sufficient. This applies in particular if the transmitter and receiver are positioned in<br />
different rooms and the radio signal has to penetrate walls and ceilings. The control<br />
system should not be installed directly near metallic surfaces (steel girders,<br />
fire doors).<br />
■ Therefore check the function of the receiver before finally carrying out<br />
mounting.<br />
Powerful local transmission systems (for example, baby intercom or neighboring<br />
transmitters) whose transmission frequency is identical to that of the control<br />
system, can interfere with the reception.<br />
The control panel can be mounted either in a flush-mounting box or directly on the<br />
wall. When specifying the mounting height ensure that the display can be read<br />
easily (recommendation: Bottom edge of the device approx. 1.35 m above top<br />
edge of completed flooring).<br />
TIP<br />
A temperature sensor is integrated in the control panel.<br />
Therefore do not mount the control panel where influencing<br />
through sources of heat is to be expected (sun radiation,<br />
radiators, outer wall). This prevents incorrect measurements!<br />
Switch off the operating voltage before you mount and<br />
connect the control panel. Pulling off the plug-and-socket<br />
connections during operation can damage the device.<br />
■ Mount the bottom plate on a flush-mounted switch box or directly on the wall.<br />
Use suitable mounting material. The oblong holes allow the bottom plate to be<br />
aligned absolutely horizontally.<br />
TIP<br />
Ensure that the mounting surface does not have any<br />
unevenness. Otherwise the bottom plate could be bent out of<br />
shape during mounting so that the control panel cannot latch<br />
in correctly!<br />
932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 11
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
3.3 "Wind/Photo" sensor<br />
12<br />
We reserve the right to carry out improvements<br />
The sensor detects the wind speed and the sun intensity.<br />
TIP<br />
Mount the "Wind/Photo/Radio clock" sensor using the<br />
enclosed mounting bracket.<br />
3 m or 10 m cables are connected fixed to the sensor. If the<br />
cable length is not sufficient, a branching box is required. The<br />
total cable length from the sensor to the central control unit<br />
may amount to a max. of 100 m in case of interference-proof<br />
laying and under use of twisted-pair cables. Further<br />
information can be found in the user and installation <strong>guide</strong> of<br />
the sensor.<br />
■ The sensor must be mounted upright with a maximum inclination of ±2°.<br />
■ The photo diodes must not be aligned to the compass directions but rather to<br />
the shading building facades.<br />
■ Mount the sensor to be easily accessible at the highest point of the roof<br />
structure or of the conservatory.<br />
■ Do not mount the sensor sheltered from the wind because the wind<br />
evaluation may otherwise be impaired.<br />
■ A photo diode has to be connected to the terminal "Photo 1" of the <strong>Wisotronic</strong><br />
<strong>dialog</strong> - otherwise the dawn/dusk control does not have any function.<br />
■ Photo diode 1 (figure below) controls the dawn/dusk control. The sensor must<br />
therefore be mounted so that this photo diode cannot be influenced during the<br />
night by street or garden light or other external light sources (such as<br />
flashlights).<br />
Fig. 3-3: Alignment of the individual photo diodes<br />
932806B0•816758•7975k0•08.10.2004
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
3.3.1 Allocation/alignment of<br />
the photo diodes<br />
The sensor may not be shaded by trees, buildings, etc. because incorrect<br />
functions may otherwise result during the sun evaluation (take the course of the<br />
sun during the day into account).<br />
Fig. 3-4: Plants or buildings can shade the "Photo" sensor in the course of the day<br />
The numbers 1 to 3 are allocated in our works to the four photo diodes, see<br />
Fig. 3-3. The allocation of the photo diodes to the individual functions of the<br />
<strong>Wisotronic</strong> <strong>dialog</strong> at a later point becomes much easier, if you connect the photo<br />
diodes to the <strong>Wisotronic</strong> <strong>dialog</strong> in accordance with their numbers. Additional<br />
information can be found in the user and installation <strong>guide</strong> of the sensor.<br />
TIP<br />
"Photo" sensor<br />
is shaded<br />
Position of the sun<br />
changes in the course of the day<br />
"Photo" sensor<br />
is shone on<br />
When selecting the mounting site you must furthermore<br />
ensure that the sensor is subjected to the same conditions<br />
(wind, sun) as the sunblind to be controlled. If this is not the<br />
case, the measured values are falsified and your sunblind may<br />
not be controlled correctly.<br />
Technical data:<br />
Measuring range Windspeed 0 - 25m/s<br />
Measuring range brightness 0 - 99 klx<br />
Signal: Wind speed 10m/s = 21Hz<br />
Brightness 1klx = 80µA<br />
Article numbers:<br />
Wind/Photo" sensor (1 facade), black<br />
with 3.5 m connecting cable and angle bracket 623 011<br />
"Wind/Photo" (1 facade) sensor, black<br />
10 m connecting cable and angle bracket 623 022<br />
"Wind/Photo" sensor (1 facade), black,<br />
10 m connecting cable and angle bracket 623 009<br />
Mounting accessories:<br />
Standpipe L = 35cm, ÿ = 20mm, wall mounting,<br />
wall distance 150 mm 632 075<br />
Standpipe L = 100cm, ˇ = 20mm, wall mounting,<br />
wall distance 150 mm 632 085<br />
Adapter for standpipes with ø 50mm 632 095<br />
932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 13
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
3.4 "Photo" (180°) sensor The "Photo" (180°) sensor is used when a wind sensor is not needed, for example<br />
at an inside sun protection system. The sensor allows light-dependent controlling<br />
of sun protection products such as internal venetian blinds, pleated blinds or<br />
external venetian blinds. It is mounted to an angle bracket and fastened with it on<br />
the facade outside. Exact information can be found in the user and installation<br />
instructions of the sensor.<br />
3.5 "Rain" (capacitive) sensor<br />
14<br />
We reserve the right to carry out improvements<br />
Technical data:<br />
Measuring range brightness 0 - 99 klx<br />
Signal: 1klx = 80µA<br />
Article number:<br />
"Photo" (180°) Sensor, black,<br />
with 3.5 m connecting cable and angle bracket 623 016<br />
In case of precipitation in the form of drizzle, rain, hail or snow the "Rain" sensor<br />
triggers a switching signal. The switching threshold of the device is set in our<br />
works to a typical value and can be adapted after commissioning by the user to<br />
the requirements of his sun protection and the local climatic conditions. If the<br />
sensor area is dry, the switching signal is canceled after an adjustable OFF delay.<br />
The sensor area is heated. The temperature of the sensor area is maintained<br />
constantly to approx. 40°C and thus prevents triggering at high humidity as well<br />
as icing at minus temperatures. After detection of precipitation the sensor area<br />
dries quickly thanks to the heating.<br />
Mount the sensor using the enclosed fastening material at an easily accessible<br />
position near your sun protection. In order to ensure optimal functioning, the<br />
precipitation must fall unhindered on the sensor area from all directions. The<br />
sensor must be cleaned quarterly.<br />
The holding plate attached to the sensor creates the angle required for the water<br />
to flow from the sensor area. This angle should not be changed by the fastening<br />
procedure. Exact information can be found in the corresponding user and<br />
installation instructions of the sensor.<br />
Note: A power supply unit is required to heat the sensor.<br />
Technical data:<br />
Measured value Precipitation Yes/No<br />
Activation time Non-delayed, sensitivity can be<br />
set<br />
Deactivation time Delayed, 1 - 10 min., adjustable<br />
Article numbers:<br />
"Rain" sensor (capacitive) 1002 325<br />
Suitable power supply unit in MCU housing 629 065<br />
Flush-type mounting cover for power supply unit 317 160<br />
Fastening set for pipe mounting 1003 255<br />
932806B0•816758•7975k0•08.10.2004
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
3.6 "Temperature" (outside)<br />
sensor<br />
3.7 "Temperature" (inside)<br />
sensor 5 to 40°C<br />
3.8 "Temperature" (inside)<br />
sensor -25 to +75°C<br />
The sensor is used to detect the outside temperature precisely and is required,<br />
for example, for ice monitoring. The sensor should be mounted as far as possible<br />
on the northern side of a building and may not be subject to direct sunshine in<br />
order to provide correct measured values to the control system. Exact mounting<br />
information can be found in the user and installation <strong>guide</strong> of the sensor.<br />
Technical data:<br />
Measuring range -25 to +75°C<br />
Signal 1kHz = 75°C<br />
Article numbers:<br />
"Temperature" (outside) sensor 628 145<br />
Fastening set for pipe mounting 1003 255<br />
The sensor for inside temperature is used to detect the room temperature<br />
precisely, for example in a conservatory. The sensor should ideally be mounted in<br />
approx. 1 m height, in the correct position and free from air draft. The sensor may<br />
not be subjected to direct sunshine in order to supply correct measured values to<br />
the control system. Exact information can be found in the user and installation<br />
<strong>guide</strong> of the sensor.<br />
Technical data:<br />
Measuring range +5 to +40°C<br />
Signal 1 kHz = 75°C<br />
Article number:<br />
"Temperature" (inside) sensor 5 to 40°C 623 038<br />
Sensor for inside temperature as above, however with extended measuring<br />
range.<br />
Technical data:<br />
Measuring range -25 to +75°C<br />
Signal 0.5 kHz = 25°C<br />
Article number:<br />
"Temperature" (inside) sensor -25 to +75°C 628 146<br />
TIP<br />
A sensor for the room temperature is already installed in the<br />
control panel. This is called the "internal" sensor. One sensor<br />
can additionally be connected to terminal strip X3 ("external"<br />
sensor).<br />
932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 15
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
3.9 Connecting sensors<br />
16<br />
We reserve the right to carry out improvements<br />
The <strong>Wisotronic</strong> <strong>dialog</strong> recognizes automatically whether and which sensors are<br />
connected. The <strong>Wisotronic</strong> <strong>dialog</strong> cannot control your sun protection system<br />
optimally and display measured values until all the required sensors have been<br />
connected.<br />
CAUTION<br />
f no sensors are connected, you cannot damage anything at<br />
the control system. Only the current room temperature is<br />
then displayed. However, take into consideration that in this<br />
case the sun protection control system cannot operate<br />
correctly, so that your sunblind could be damaged!<br />
Only the sensors described below may be connected to the <strong>Wisotronic</strong>.<br />
Otherwise the approval of the manufacturer is to be obtained.<br />
The following sensor inputs are available:<br />
1 x "Temperature" (external)<br />
1 x "Wind"<br />
1 x "Rain"<br />
3 x "Photo"<br />
Sensors may not be connected in parallel!<br />
932806B0•816758•7975k0•08.10.2004
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
4. Connectioninformation<br />
ATTENTION<br />
TIP<br />
ATTENTION<br />
A line-side disconnecting device is to be provided in the fixed<br />
installation in order to disconnect the <strong>Wisotronic</strong> <strong>dialog</strong> from<br />
the supply voltage (power breaker conforming to EN 60335-1,<br />
Section 25.2, for example, miniature circuit-breaker). Any<br />
associated motor control units (MCU) and their consumers<br />
may not be protected against short circuits by means of this<br />
miniature circuit-breaker.<br />
The <strong>Wisotronic</strong> <strong>dialog</strong> must be separated from the supply<br />
voltage before the housing is opened!<br />
A screwdriver size 0 is required to tighten the sensor<br />
terminals. Do not use a battery-driven screwdriver!<br />
EN 60335-1 is to be applied when connecting the power<br />
supply cable. (Wire cross-section, type of conductor, additional<br />
securing against loosening, strain relief, wire end ferrules<br />
at stranded conductors, circuit-breakers).<br />
The voltage drop diagrams of the looped-through motor control<br />
units are to be observed with regard to the looping<br />
through of the supply voltage.<br />
The external +12V voltages provided by the <strong>Wisotronic</strong> <strong>dialog</strong><br />
are provided exclusively for works-own sensors.<br />
In accordance with VDE 0022 responsibility for observance of<br />
the utility-company or VDE regulations lies with the operator<br />
and the person installing.<br />
The lines specified in the line diagram are minimum crosssections<br />
designed for copper, without consideration of the<br />
length and the resulting voltage drops.<br />
If lines are laid outdoors, the corresponding VDE regulations<br />
are to be observed. In addition the lines must be suitable for<br />
outdoor use.<br />
The distance to the power cables must amount to at least 20<br />
cm. Laying parallel to live lines is to be avoided! The<br />
insulation voltage between the screen and conductors must<br />
be > 2.5 kV. The lines should be laid in one piece.<br />
By default commercial light-current cables, for example<br />
JY(St)Y, are for pushbutton, sensor and network lines. As a<br />
rule this is sufficient with regard to external EMC influences,<br />
for example in living areas at line lengths up to 50 m. Optimum<br />
protection against external EMC influences is, on the<br />
other hand, provided by high-quality lines with braided screen<br />
(not foil screen!) and closely twisted pair conductors. The<br />
longer the line, the greater the interference susceptibility!<br />
Therefore only lay high-quality lines at line lengths above 50<br />
m up to a max. of 100 m!<br />
If the sunblind is moved down for maintenance, repair,<br />
cleaning, etc., the complete sun protection system must be<br />
shut down afterwards by means of the line-side disconnecting<br />
device.<br />
932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 17
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
4.1 Handling of the<br />
spring-load<br />
terminals<br />
4.2 Handling of the<br />
screw/clamp type<br />
terminals<br />
18<br />
We reserve the right to carry out improvements<br />
WARNING<br />
Work on the 230V Power supply may only be carried out by<br />
qualified electrical personnel (in accordance with VDE 0100).<br />
1<br />
Fig. 4-1: Connecting and loosening the cable connections<br />
The power supply cable, the drive and the central control unit are connected with<br />
spring-load terminals: After the conductor has been bared, press it into the<br />
terminal (1) until the insulation of the conductor immerses into the terminal and<br />
the conductor is held firmly in the terminal (2). In order to loosen the connection,<br />
press in the corresponding release button with a screwdriver until it stops and<br />
then pull the conductor out of the terminal (3).<br />
The connections of the sensor are realized as screw/clamp-type terminals. In<br />
order to facilitate connecting the terminal blocks can be removed and the<br />
conductors then connected. Use a screwdriver size 0 to this purpose. After<br />
connecting has been completed, the terminals are put back on.<br />
2<br />
932806B0•816758•7975k0•08.10.2004<br />
3
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
5. Wiring diagrams<br />
Terminal strip X1 For connecting<br />
the power supply cable 230V AC<br />
Terminal strip X3 For connecting<br />
a external "Temperature" sensor<br />
Fig. 5-1: Terminals of the <strong>Wisotronic</strong> <strong>dialog</strong><br />
1 2 3 4 5 6<br />
X1<br />
X2<br />
1 2 3 4<br />
X4<br />
X3 X5<br />
Terminal strip X4 For connecting<br />
the "Photo" sensors<br />
ATTENTION<br />
Terminal strip X2<br />
Isolated output for connecting a<br />
"Geschossansteuerverteiler",<br />
motor control units (MCU)<br />
or a drive.<br />
Fuse (accessible after cover has<br />
been opened).<br />
Note: The device inside does not<br />
contain any parts which can be<br />
maintained. In case of a malfunction<br />
the installed fuse may<br />
only be replaced by qualified<br />
electrical personnel.<br />
Terminal strip X5 For connecting<br />
the "Wind" and "Rain" sensors<br />
Lay the cables for the drive and power supply from above<br />
into the distributor box and the cables for the sensors from<br />
below!<br />
Cables with supply voltage have to be laid at least 8 mm<br />
away from sensor cables.<br />
If 24 V control cables are connected to terminal strip X2,<br />
these have to be laid at least 8 mm away from the 230V<br />
cables. Otherwise the 24 cables have to be double-insulated<br />
(for example with silicone-rubber insulation)!<br />
932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 19
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
5.1 "Wind/Photo" sensor<br />
20<br />
Photo 3<br />
Photo 2<br />
Photo 1<br />
Fig. 5-2: Wiring diagram „Wind/Photo“ sensor<br />
We reserve the right to carry out improvements<br />
+12V DC<br />
+12V DC<br />
"Wind/Photo" sensor<br />
Photo 1<br />
Photo 1<br />
Photo 2<br />
Photo 2<br />
Photo 3<br />
Photo 3<br />
0V<br />
Wind<br />
0V<br />
Wind<br />
X3 1 2 3 1 2 3 4 1 2 3 4<br />
X4<br />
*Use twisted pair cable, interference-proof laying.<br />
See section "Connection information"!<br />
Branching box<br />
mounted<br />
by customer<br />
JY(St)Y4x2x0,8mmø<br />
max. length of line 100 meters*<br />
X5<br />
932806B0•816758•7975k0•08.10.2004
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
5.2 "Photo" (180°) sensor<br />
Photo 3<br />
Photo 2<br />
Photo 1<br />
Fig. 5-3-: Wiring diagram „Photo“ (180°) sensor<br />
+12V DC<br />
+12V DC<br />
X4<br />
"Photo" (180°)<br />
sensor<br />
Photo 1<br />
Photo 1<br />
Photo 2<br />
Photo 2<br />
Photo 3<br />
Photo 3<br />
X3 1 2 3 1 2 3 4 1 2 3 4<br />
*Use twisted pair cable, interference-proof laying.<br />
See section "Connection information"!<br />
Branching box<br />
mounted<br />
by customer<br />
JY(St)Y2x2x0,8mmø<br />
max. length of line 100 meters*<br />
932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 21<br />
X5
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
5.3 „Rain“ (capacitive) sensor<br />
Fig. 5-4: Wiring diagram „Rain“ (capacitive) sensor<br />
22<br />
4xAWG 24C UL<br />
(UV - resistent)<br />
JY(St)Y2x2x0,8mmø<br />
max. length of<br />
line 100 meters*<br />
1 2 3 4<br />
X4<br />
We reserve the right to carry out improvements<br />
"Rain" (capacitive)<br />
sensor<br />
Branching box<br />
mounted<br />
by customer<br />
H05RR-F4G0,75mm 2 sw<br />
Regen<br />
0V<br />
X3 1 2 3 1 2 3 4 1 2 3 4<br />
X5<br />
*Use twisted pair cable, interference-proof laying.<br />
See section "Connection information"!<br />
N L1<br />
Power supply for<br />
"Rain" sensor<br />
NYM-J 3x1,5 mm 2<br />
L<br />
N<br />
Power<br />
supply<br />
230V AC<br />
932806B0•816758•7975k0•08.10.2004
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
5.4 „Temperature“ (outside) sensor<br />
JY(St)Y2x2x0,8mmø<br />
max. length of<br />
line 100 meters*<br />
X3<br />
+12V<br />
+12V<br />
0V<br />
Temp<br />
X4<br />
*Use twisted pair cable, interference-proof laying.<br />
See section "Connection information"!<br />
Fig. 5-5: Wiring diagram „Temperature“ (outside) sensor<br />
ϑ<br />
T<br />
°C<br />
"Temperature"<br />
(outside) sensor<br />
4xAWG 26C UL<br />
(UV - resistent)<br />
Branching box,<br />
mounted by customer<br />
1 2 3 1 2 3 4 1 2 3 4<br />
932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 23<br />
X5
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
5.5 „Temperature“ (inside) +5 to +40°C sensor<br />
24<br />
JY(St)Y2x2x0,8mmø<br />
max. length of<br />
line 100 meters*<br />
X3<br />
Fig. 5-6: Wiring diagram „Temperature“ (inside) +5 to -40°C sensor<br />
+12V<br />
0V<br />
Temp<br />
We reserve the right to carry out improvements<br />
ϑ<br />
+12V<br />
0V<br />
+ ⊥<br />
↓<br />
"Temperature" (inside) +5 to +40°C<br />
sensor<br />
JY(St)Y2x2x0,8mmø<br />
Branching box<br />
mounted by customer<br />
1 2 3 1 2 3 4 1 2 3 4<br />
X4<br />
*Use twisted pair cable, interference-proof laying.<br />
See section "Connection information"!<br />
X5<br />
932806B0•816758•7975k0•08.10.2004
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
5.6 "Temperature" (inside) -25 to +75°C sensor<br />
X1<br />
JY(St)Y2x2x0,8mmø<br />
max. length of<br />
line 100 meters*<br />
X3<br />
+12V<br />
Fig. 5-7: Wiring diagram "Temperature" (inside) -25 to +75°C sensor<br />
ϑ<br />
+12V<br />
0V<br />
0V<br />
Temp<br />
"Temperature"<br />
(inside) -25 to +75°C sensor<br />
JY(St)Y2x2x0,8mmø<br />
Branching box<br />
mounted by customer<br />
X4<br />
*Use twisted pair cable, interference-proof laying.<br />
See section "Connection information"!<br />
X52 5<br />
932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 25
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
5.7 Connection of Power supply and control cables<br />
Fig. 5-8: Power supply and control cables<br />
26<br />
Power supply<br />
230 V AC<br />
50Hz / 16A<br />
NYM-J 3x 1,5mm 2<br />
We reserve the right to carry out improvements<br />
To "Geschossansteuerverteiler" (power supply)<br />
or to the motor control units (MCU).<br />
Refer to the documentation "Anschlusspläne",<br />
(german) Art.-Nr. 816 345<br />
P<br />
1 2 3 4 5 6<br />
X1<br />
ACHTUNG<br />
PE<br />
PE<br />
N<br />
N<br />
L<br />
L<br />
P E<br />
X2<br />
F1 3,15 AT<br />
1<br />
2 3 4<br />
If 24 V control cables are connected to terminal strip X2, these<br />
have to be laid at least 8 mm away from the 230V cables.<br />
Otherwise the 24V cables have to be double-insulated (for<br />
example with silicone-rubber insulation)!<br />
E<br />
932806B0•816758•7975k0•08.10.2004
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
5.8 Connecting single drive<br />
Power supply<br />
230 V AC<br />
50Hz / 16A<br />
NYM-J 3x 1,5mm 2<br />
Fig. 5-9: Connecting single drive<br />
H05RR-F4G0,75mm 2 sw<br />
1 2 3 4 5 6<br />
X1<br />
PE<br />
PE<br />
N<br />
N<br />
L<br />
L<br />
F1 3,15 AT<br />
932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 27<br />
1<br />
1<br />
gnge<br />
bl<br />
br<br />
P<br />
X2<br />
1<br />
Motor 1<br />
M1~<br />
2<br />
1<br />
3<br />
3<br />
3<br />
sw<br />
2 Plug connection<br />
2<br />
2 3 4<br />
Caution! Only one drive may be<br />
connected. The drive is damaged<br />
in case of parallel connections!
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
5.9 Mounting the contol panel<br />
5.10 De-mounting the control<br />
panel<br />
28<br />
We reserve the right to carry out improvements<br />
■ Switch off the supply voltage of the <strong>Wisotronic</strong>.<br />
■ Insert the connecting cables into the plug-and-socket connection provided at<br />
the control panel. Note: Frequent inserting and removal of the plug-and-socket<br />
connection can damage it!<br />
■ Then clip the control panel onto the supply unit.<br />
■ Switch on the supply voltage of the <strong>Wisotronic</strong>.<br />
Fig. 5-10: Mounting the control panel<br />
■ Switch off the supply voltage of the <strong>Wisotronic</strong>.<br />
■ In order to remove the control panel, pull simultaneously at the side vent slots<br />
at the control panel.<br />
■ Repeat at the opposite side and remove the control panel.<br />
■ Loosen the plug-and-socket connection<br />
Pull simultaneously<br />
carefully here<br />
Fig. 5-11: Removing the control panel<br />
Control panel<br />
Catch<br />
Power unit<br />
Insert connecting<br />
line here<br />
932806B0•816758•7975k0•08.10.2004
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
6. Commissioning<br />
6.1 Automatic presetting<br />
6.1.1 Password<br />
TIP<br />
Before the commissioning the required sensors have to be<br />
connected!<br />
As soon as the supply voltage is activated, the <strong>Wisotronic</strong> <strong>dialog</strong> automatically<br />
carries out the presettings for articulated arm awnings. This is the sun protection<br />
product which is most sensitive to weather influences. After approx. 10 seconds<br />
the current indoor temperature is display and the symbols for the manual<br />
operation UP / DOWN are shown in the display. The connected sunblind can now<br />
be moved manually to try it out.<br />
In order to open the service settings you must enter the password:<br />
■ Turn the function dial until the following display appears:<br />
Serviceeinstellungen<br />
932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 29<br />
{<br />
■ Select the menu item (button {). The following display appears:<br />
Zugangscode<br />
eingeben<br />
0000<br />
* + | }<br />
You now have to enter a password (if you have already entered a password, this<br />
menu is no longer displayed. Instead the "Product” menu is displayed<br />
immediately). Enter the password "5858":<br />
■ ■ Press the button + momentarily until the first number of the password is<br />
displayed at the first position. Change to the next position by pressing the<br />
button * momentarily. Enter all the numbers by the same method and then<br />
press the button {. The following display appears:<br />
Produkt<br />
{ }<br />
If the incorrect password was entered, 0000 is displayed again and you have<br />
to enter the password again.<br />
■ In order to exit the menu press the }button twice consecutively. This<br />
completes the process.
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
6.2 Changing the user<br />
language<br />
30<br />
We reserve the right to carry out improvements<br />
The default setting of the user language is "Deutsch". Proceed as follows in order<br />
to change the user language to "English":<br />
■ Turn the function dial until the following display appears:<br />
Serviceeinstellungen<br />
{<br />
■ Select the menu item (button {). The following display appears:<br />
Produkt<br />
{ }<br />
■ Turn the function dial until the following display appears:<br />
Sprache<br />
{ }<br />
■ Select the menu item (button {). The following display appears:<br />
Sprache<br />
Deutsch<br />
— + | }<br />
■ Change the settings by using the buttons — + and then press the button<br />
| (save) If you want to exit the menu without saving the changes, press the<br />
}button twice consecutively. This completes the process.<br />
932806B0•816758•7975k0•08.10.2004
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
6.3 Setting the product type<br />
You can now set your product (slat products, cloth products, roller shutters, etc.)<br />
in order to adapt the <strong>Wisotronic</strong> <strong>dialog</strong> optimally to your requirements.<br />
Each of these products has different properties. This means that they also react<br />
differently to wind, require other turn times and runtimes or are perhaps<br />
positioned inside and therefore do not require rain and wind protection, etc.. So<br />
that you do not have to enter all the product-dependent setting values and limits<br />
whenever you set a product in the <strong>Wisotronic</strong>, <strong>Wisotronic</strong> <strong>dialog</strong> carries out this<br />
work for you. The required values are already stored for many products. All the<br />
product-dependent setting values are programmed by only pressing a button.<br />
Let us assume that you have connected outside venetian blinds and now want to<br />
set this product type at the <strong>Wisotronic</strong> <strong>dialog</strong>. Proceed as follows in order to do<br />
so:<br />
■ Turn the function dial until the following display appears:<br />
Service<br />
settings<br />
932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 31<br />
{<br />
■ Select the menu item (button {). The following display appears:<br />
Product<br />
{ }<br />
■ Select this menu item (button {). The following display appears:<br />
Product<br />
Product type<br />
Fold.arm awning<br />
— + | }<br />
■ Change the product type by using the buttons — + and then press the<br />
button | (save). If you want to exit the menu without saving the changes,<br />
press the }button twice consecutively. This completes the process.<br />
■ Quit the setting menu by pressing the } button twice.<br />
■ De-energize the <strong>Wisotronic</strong> for approx. 5 seconds at the line-side fuse and<br />
then switch it on again. This blocks the access to the service settings again so<br />
that they can only be opened again by entering the password.<br />
ATTENTION<br />
The basic settings of the controlled products have to be<br />
adapted to the manufacturer specifications, if necessary!
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
6.4 Allocating connected<br />
Sensors<br />
32<br />
We reserve the right to carry out improvements<br />
The “Temperature” sensors connected to the <strong>Wisotronic</strong> <strong>dialog</strong> now have to be<br />
allocated. In the process you specify which sensor is used to control the<br />
temperature-specific functions.<br />
The <strong>Wisotronic</strong> disposes of a temperature sensor built into the device with which<br />
the required measured values can be recorded. Alternatively an additional sensor<br />
input is available. Either a sensor for interior temperature or for external<br />
temperature can be connected here. You can set which sensor is to be evaluated<br />
by the temperature control:<br />
■ Turn the function dial until the following display appears:<br />
User<br />
settings<br />
{<br />
■ Select the menu item (button {). The following display appears:<br />
Sun<br />
control<br />
{ }<br />
■ Turn the function dial until the following display appears:<br />
Temperature<br />
control<br />
{ }<br />
■ Select the menu item (button {). The following display appears:<br />
Temperature<br />
control<br />
OFF<br />
— + | }<br />
■ Turn the function dial until the following display appears:<br />
Allocation<br />
temp. sensor<br />
External<br />
— + | }<br />
If the value “Internal” is set, the temperature control evaluates the sensor built<br />
into the device. If the value “External” is set, the temperature control evaluates<br />
the sensor which is connected externally.<br />
TIP<br />
It is not possible to evaluate both sensors!<br />
932806B0•816758•7975k0•08.10.2004
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
6.5 Setting the time and date<br />
■ Change the settings by using the buttons — + and then press the button |<br />
(save). If you want to exit the menu without saving the changes, press the<br />
}button twice consecutively. This completes the process.<br />
Commissioning is completed when the sensors are allocated.<br />
A complete overview of all the functions of the <strong>Wisotronic</strong> <strong>dialog</strong> can be found in<br />
the corresponding user instructions. Please refer to it in order to adapt the control<br />
system optimally to your requirements.<br />
TIP<br />
After you have carried out your settings and have completed<br />
them, de-energize the device for approx. 5 seconds and then<br />
switch it on again. This blocks the access to the service<br />
settings again so that they can only be opened again by<br />
entering the password. This ensures that unauthorized<br />
persons do not have access to the service settings!<br />
If the date and time are not displayed correctly, you can correct this simply:<br />
■ Turn the function dial until the following display appears:<br />
User<br />
settings<br />
932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 33<br />
{<br />
■ Select the menu item (button {). The following display appears:<br />
Sun<br />
control<br />
{ }<br />
■ Turn the function dial until the following display appears:<br />
Date / Time<br />
{ }<br />
■ The following date and time displays are examples and may deviate from the<br />
display on your <strong>Wisotronic</strong>. Select the menu item (button {). The following<br />
display appears:<br />
Date / Time<br />
Time<br />
15:00<br />
— + | }
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
34<br />
We reserve the right to carry out improvements<br />
■ Set the current time by using the buttons — + and then press the button |<br />
(save)<br />
■ Turn the function dial until the following display appears:<br />
Date / Time<br />
Year<br />
2004<br />
— + | }<br />
■ Set the current year by using the buttons — + and then press the button |<br />
(save)<br />
■ Turn the function dial until the following display appears:<br />
Date / Time<br />
Month<br />
July<br />
— + | }<br />
■ Set the current month by using the buttons — + and then press the button<br />
| (save)<br />
■ Turn the function dial until the following display appears:<br />
Datum / Uhrzeit<br />
Day<br />
23<br />
— + | }<br />
■ Set the current day by using the buttons — + and then press the button |<br />
(save).<br />
■ Turn the function dial until the following display appears:<br />
Date / Time<br />
Weekday<br />
Friday<br />
— + | }<br />
■ Set the current weekday by using the buttons — + and then press the<br />
button | (save). Quit the setting menu by pressing the } button.<br />
This completes the process.<br />
932806B0•816758•7975k0•08.10.2004
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
7. Factory settings<br />
Setting step Unit<br />
Sun control<br />
Fig. 7-1: Factory settings (user settings)<br />
Articulated<br />
arm<br />
awning<br />
Conserv.-/<br />
Facadeawning<br />
User settings<br />
Outside<br />
venetian<br />
blind<br />
Roller<br />
shutter<br />
Pleated<br />
blind<br />
Inside<br />
venetian<br />
blind<br />
Sun control ON/OFF ON/OFF ON ON ON OFF ON ON<br />
Limit UP klx 30 30 15 30 30 30<br />
Delay UP min 10 10 20 10 10 10<br />
Limit OPEN klx --- --- --- --- --- ---<br />
Delay OPEN min 0 0 0 0 0 0<br />
Limit DOWN klx 50 50 35 50 50 50<br />
Delay DOWN min 5 5 2 5 5 5<br />
Position DOWN % 100 100 100 100 100 100<br />
Angle DOWN<br />
Dawn/dusk control<br />
Degrees 0 0 38 0 0 38<br />
Dawn/dusk control ON/OFF OFF OFF OFF ON OFF OFF<br />
Limit UP lx 30 30 30 30 30 30<br />
Limit DOWN lx 80 80 80 80 80 80<br />
Angle DOWN<br />
Temperature control<br />
Degrees 0 0 80 0 0 80<br />
Temperature control ON/OFF OFF OFF OFF OFF OFF OFF<br />
Direct control<br />
Operating mode<br />
Enable sun Direct control Direct control Direct control Direct control Direct control Direct control<br />
Limit UP/OFF ° C 22 22 22 22 22 22<br />
Limit DOWN/ON<br />
Rain monitoring<br />
° C 26 26 26 26 26 26<br />
Rain monitoring<br />
Timer switch<br />
ON/OFF ON ON OFF OFF OFF OFF<br />
Timer switch ON/OFF OFF OFF OFF OFF OFF OFF<br />
Mo - Fr UP hrs:min 18:00 18:00 8:00 8:00 8:00 8:00<br />
Mo - Fr DOWN hrs:min 8:00 8:00 22:00 22:00 22:00 22:00<br />
Sa - Su UP hrs:min 18:00 18:00 8:00 8:00 8:00 8:00<br />
Sa - Su DOWN hrs:min 8:00 8:00 22:00 22:00 22:00 22:00<br />
Angle DOWN<br />
Comfort timer<br />
Degrees 0 0 80 0 0 80<br />
Comfort timer ON/OFF OFF OFF OFF OFF OFF OFF<br />
Mo - Fr ON hrs:min 8:00 8:00 8:00 8:00 8:00 8:00<br />
Mo - Fr OFF hrs:min 18:00 22:00 22:00 22:00 22:00 22:00<br />
Sa - Su ON hrs:min 8:00 8:00 8:00 8:00 8:00 8:00<br />
Sa - Su OFF<br />
Manual operation<br />
hrs:min<br />
Dead man´s mode<br />
18:00 22:00 22:00 22:00 22:00 22:00<br />
Mode<br />
Time mode<br />
Permanent mode<br />
Continuous mode<br />
Permanent mode Permanent mode Time mode Permanent mode Permanent mode Time Mode<br />
Angle DOWN<br />
Display<br />
Degrees 0 0 38 0 0 38<br />
Contrast % 40<br />
Backlight dimmed % 50<br />
932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 35
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
Setting step Unit<br />
Product<br />
Product type -<br />
Fig. 7-2: Factory settings (Service settings)<br />
36<br />
Articulated<br />
arm<br />
awning<br />
Articulated<br />
arm<br />
awning<br />
We reserve the right to carry out improvements<br />
Conserv.-/<br />
Facadeawning<br />
Service settings<br />
Conservatory<br />
awning<br />
Outside<br />
venetian<br />
blind<br />
Outside<br />
venetian<br />
blind<br />
Roller<br />
shutter<br />
Pleated<br />
blind<br />
Roller shutter Pleated blind<br />
Inside<br />
venetian<br />
blind<br />
Inside<br />
venetian<br />
blind<br />
Runtime UP min:sec 1:00 2:00 2:30 2:30 1:20 2:30<br />
Runtime DOWN min:sec 1:00 2:00 2:30 2:30 1:20 2:30<br />
Turn time sec 0 0 1,6 0 0 1,2<br />
Slat angle max. Degrees 0 0 80 0 0 80<br />
Slat angle min. Degrees 0 0 -80 0 0 -80<br />
Control type<br />
Drive direct/<br />
with MCU<br />
Drive with<br />
MCU<br />
Drive with<br />
MCU<br />
Drive with<br />
MCU<br />
Drive with<br />
MCU<br />
Drive with<br />
MCU<br />
Drive with<br />
MCU<br />
Wind monitoring<br />
Wind monitoring ON/OFF ON ON ON OFF OFF OFF<br />
Limit UP m/s 8 10 12 --- --- ---<br />
Delay UP sec 1 1 5 0 0 0<br />
Delay OFF<br />
Ice monitoring<br />
min 10 10 10 0 0 0<br />
Ice monitoring ON/OFF OFF OFF OFF OFF OFF OFF<br />
Limit UP ° C 3 3 3 3 3 3<br />
Ice alert automatic reset<br />
System settings<br />
ON/OFF ON ON ON ON ON ON<br />
Integrated temperature<br />
sensor offset<br />
° C 2<br />
Duration wind sensor<br />
test<br />
hrs 99<br />
Software version - Dependent on the installed software<br />
Language<br />
Language Deutsch/English Deutsch<br />
932806B0•816758•7975k0•08.10.2004
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
8. Custom settings<br />
Setting step Unit Setting<br />
User settings<br />
Sun control<br />
Sun control<br />
ON/OFF<br />
ON/OFF<br />
Limit UP klx<br />
Delay UP min<br />
Limit OPEN klx<br />
Delay OPEN min<br />
Limit DOWN klx<br />
Delay DOWN min<br />
Position DOWN %<br />
Angle DOWN<br />
Dawn/dusk control<br />
Degrees<br />
Dawn/dusk control ON/OFF<br />
Limit UP lx<br />
Limit DOWN lx<br />
Angle DOWN<br />
Temperature control<br />
Degrees<br />
Temperature contropl ON/OFF<br />
Direct control<br />
Operating mode<br />
Enable sun<br />
Limit UP/OFF ° C<br />
Limit DOWN/ON<br />
Rain monitoring<br />
° C<br />
Rain monitoring<br />
Timer switch<br />
ON/OFF<br />
Timer switch ON/OFF<br />
Mo - Fr UP hrs:min<br />
Mo - Fr DOWN hrs:min<br />
Sa - Su UP hrs:min<br />
Sa - Su DOWN hrs:min<br />
Angle DOWN<br />
Comfort timer<br />
Degrees<br />
Comfort timer ON/OFF<br />
Mo - Fr ON hrs:min<br />
Mo - Fr OFF hrs:min<br />
Sa - Su ON hrs:min<br />
Sa - Su OFF<br />
Manual operating<br />
hrs:min<br />
Dead man´s mode<br />
Operating mode<br />
Time mode<br />
Permanent mode<br />
Continuous mode<br />
Angle DOWN<br />
Display<br />
Degrees<br />
Contrast %<br />
Backlight dimmed %<br />
Fig. 8-1: Custom settings (service settings)<br />
932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 37
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
38<br />
Setting step Unit Setting<br />
Product<br />
Product type<br />
Service settings<br />
Articulated arm<br />
awning<br />
Conservatory<br />
awning<br />
Outside venetian<br />
blind<br />
Roller shutter<br />
Pleated blind<br />
Inside venetian<br />
blind<br />
Runtime UP min:sec<br />
Runtime DOWN min:sec<br />
Turn time sec<br />
Slat angle max. Degrees<br />
Slat angle min. Degrees<br />
Control type<br />
Wind monitoring<br />
Drive direct/<br />
with MCU<br />
Wind monitoring ON/OFF<br />
Limit UP m/s<br />
Delay UP sec<br />
Delay OFF<br />
Ice monitoring<br />
min<br />
Ice monitoring ON/OFF<br />
Limit UP ° C<br />
Ice alert automatic reset<br />
System<br />
ON/OFF<br />
Integrated temperature<br />
sensor offset<br />
° C<br />
Duration wind sensor<br />
test<br />
hrs<br />
Software version -<br />
Language<br />
Language Deutsch/English<br />
Fig. 8-2: Eigene Einstellungen (Serviceinstellungen)<br />
We reserve the right to carry out improvements<br />
932806B0•816758•7975k0•08.10.2004
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
9. Technical data<br />
<strong>Wisotronic</strong> <strong>dialog</strong> 1-channel<br />
Supply<br />
min typ max unit<br />
Operating voltage 207 230 253 VAC<br />
Power consumption<br />
Outputs (Isolated)<br />
2,5 4 VA<br />
Switching capacity<br />
at 230 VAC / cos ϕ = 0,6<br />
700 VA<br />
Switching capacity at 24 VDC 72 W<br />
Microfuse<br />
Integrated "Temperature" sensor<br />
3,15 AT<br />
Measuring range<br />
HF-Receiver<br />
-25 +75 ° C<br />
Receive frequency ASK (OOK) 433,92 MHz<br />
Sensing range<br />
Ambient conditions<br />
30 m<br />
Operating temperature 0 +20 +40 ° C<br />
Storage temperature 0 +20 +50 ° C<br />
Humidity (non-condensing) 10 40 85 %RH<br />
Housing<br />
Degree of protection:<br />
In flush-type housing IP30<br />
In surface-type housing IP30<br />
Safety class II<br />
Field of application: Clean ambient conditions<br />
Connection<br />
Drive, Power supply Spring-load terminals<br />
Sensors Plugged/Screwed terminals<br />
Terminals<br />
Drive, Power supply 0,14...1,5 mm 2<br />
Sensors 0,14...1,5 mm 2<br />
Test Standards<br />
EN60730-1: 2002<br />
EN50081-1: 1992<br />
EN50082-1: 1997<br />
EN300220-3: 2000<br />
EN301489-3: 2001<br />
Other<br />
Automatic Type 1<br />
Method of operation<br />
Software class A<br />
Display Graphical LC-Display with background<br />
lighting<br />
Program control Clear text display / Icons<br />
Program input 4 button / dial with pushbutton<br />
Output isolated contact set<br />
Conformity<br />
932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 39
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
40<br />
We reserve the right to carry out improvements<br />
Fig. 9-1: Dimensions<br />
Article numbers<br />
<strong>Wisotronic</strong> <strong>dialog</strong> 1K UP EWFS 1002 556<br />
with 1-<strong>Channel</strong> remote control and<br />
„Wind/Photo“ sensor<br />
<strong>Wisotronic</strong> <strong>dialog</strong> 1K UP EWFS 1002 578<br />
with 1-<strong>Channel</strong> remote control<br />
Surface-type mounting set 1002 570<br />
TIP<br />
94<br />
170<br />
68<br />
65,5<br />
The device has been checked for observance of the statutory<br />
regulations on emitted interference in accordance with DIN<br />
EN 50081-1/1992 and on immunity to interference in<br />
accordance with DIN EN 50082-1/1992. The requirements are<br />
fulfilled or exceeded in connection with the specified supply<br />
cables and sensors of the manufacturer in all cases. DIN EN<br />
50081-1 and DIN EN 50082-1 apply for usage of the device in<br />
living areas, business and trade areas as well as in small<br />
companies. Additional measures may be required if used in<br />
industrial environments.<br />
932806B0•816758•7975k0•08.10.2004
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
10. User information<br />
For use in:<br />
A, B, D, DK, E, F, FIN, GB, GR, I, IRL, L, NL, P, S, CH, IS, N.<br />
Transmitter and reciever for sunblind remote control.<br />
The device complies at intended use with the essential requirements, which are<br />
fixed in the following EC-Guidelines and harmonized standards:<br />
- Directive on radio equipment and telecommunications terminal equipment and<br />
the mutual recognition of their conformity 1999/5/EC(R&TTE)<br />
- Directive on electromagnetic compability 89/336/EEC<br />
- Low voltage directive 73/23/EWG<br />
Link to declaration of confirmity:<br />
http://www.warema.de<br />
932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 41
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />
Control Unit EWFS ®<br />
11. Notes<br />
42<br />
We reserve the right to carry out improvements<br />
932806B0•816758•7975k0•08.10.2004