7975k0/Ausgabe 11.2004<br />

WAREMA controls<br />

<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

<strong>Installation</strong> <strong>guide</strong><br />

(Please save these Instructions for future use)<br />

Valid as from November 1, 2004<br />

932806B0•816758•7975k0•08.10.2004


General remarks<br />

General Remarks<br />

The publication of this manual<br />

supercedes all previous corresponding<br />

documentation.<br />

We reserve the right to make<br />

alterations in the interests of technical<br />

progress.<br />

Considerable care was taken in<br />

producing the text and graphics in this<br />

documentation but it is impossible to<br />

rule out errors completely.<br />

WAREMA provides you with a<br />

complete range of sun protection<br />

systems for windows, facades and<br />

glazed structures. Please contact the<br />

export department if you need any<br />

documentation on:<br />

– sun protection control systems<br />

– outside venetian blinds<br />

– inside venetian blinds<br />

– roller shutters<br />

– facade awnings<br />

– vertical awnings<br />

– markisolettes<br />

– conservatory awnings<br />

– articulated arm awnings<br />

– cassette awnings<br />

– basket awnings<br />

– Dutch canopy awning<br />

– insect screens<br />

– sun protections for roof windows<br />

– vertical louvre blinds<br />

– pleated blinds<br />

– roller blinds<br />

– black-out systems<br />

Safety Instructions<br />

Electrical installation work must be left<br />

strictly to qualified electricians. Only<br />

then is there any guarantee that your<br />

country´s statutory regulations are<br />

complied with and that the installation<br />

provisions of your local power supply<br />

company are properly observed. The<br />

user may be placed at serious risk if<br />

the equipment is wrongly installed.<br />

For further information please refer the<br />

the available user and installation<br />

<strong>guide</strong>s.<br />

Imprint<br />

WAREMA Renkhoff SE<br />

Hans-Wilhelm-Renkhoff Strasse 2<br />

D-97828 Marktheidenfeld/Main<br />

2<br />

Headquarter<br />

WAREMA Renkhoff SE<br />

Hans-Wilhelm-Renkhoff Strasse 2<br />

D-97828 Marktheidenfeld/Main<br />

P.o. box 13 55<br />

D-97822 Marktheidenfeld/Main<br />

Phone:+49 (0) 9391/20-0<br />

Fax: +49 (0) 9391/20-4299<br />

http://www.warema.com<br />

Sales Department (Sun protection<br />

control systems):<br />

Phone:+49 (0) 9391/20-3730;<br />

Fax: +49 (0) 9391/20-3739<br />

Application technique:<br />

Phone:+49 (0) 9391/20-6720;<br />

Fax: +49 (0) 9391/20-6729<br />

Service:<br />

Phone:+49 (0) 9391/20-6760;<br />

Fax: +49 (0) 9391/20-6769<br />

WAREMA and the WAREMA logo are trademarks of WAREMA Renkhoff SE.<br />

All other brand names or product names mentioned in this documentation are<br />

trade marks or registered trade marks of their respective owners.<br />

© 2004, WAREMA Renkhoff SE<br />

932806B0•816758•7975k0•08.10.2004


Table of contents<br />

1. General ................................................................................................................... 4<br />

2. For your safety ..................................................................................................... 5<br />

2.1 Pictogram and symbol explanations ................................................................ 5<br />

2.2 Usage to the intended purpose ....................................................................... 7<br />

2.3 Target group ..................................................................................................... 7<br />

2.4 Working safely ................................................................................................. 8<br />

2.5 Software version.............................................................................................. 8<br />

3. Mounting ............................................................................................................... 9<br />

3.1 Procedure ........................................................................................................ 9<br />

3.2 <strong>Installation</strong> ........................................................................................................... 10<br />

3.2.1 Flush-type mounting ................................................................................ 10<br />

3.2.2 Surface-type mounting ............................................................................. 10<br />

3.3 "Wind/Photo" sensor ...................................................................................... 12<br />

3.3.1 Allocation/alignment of the photo diodes................................................. 13<br />

3.4 "Photo" (180°) sensor ..................................................................................... 14<br />

3.5 "Rain" (capacitive) sensor .............................................................................. 14<br />

3.6 "Temperature" (outside) sensor ...................................................................... 15<br />

3.7 "Temperature" (inside) sensor 5 to 40°C ........................................................ 15<br />

3.8 "Temperature" (inside) sensor -25 to +75°C ................................................... 15<br />

3.9 Connecting sensors ....................................................................................... 16<br />

4. Connection-information ..................................................................................... 17<br />

4.1 Handling of the spring-load terminals ............................................................ 18<br />

4.2 Handling of the screw/clamp type terminals ................................................. 18<br />

5. Wiring diagrams .................................................................................................. 19<br />

5.1 "Wind/Photo" sensor ...................................................................................... 20<br />

5.2 "Photo" (180°) sensor ..................................................................................... 21<br />

5.3 „Rain“ (capacitive) sensor ............................................................................. 22<br />

5.4 „Temperature“ (outside) sensor .................................................................... 23<br />

5.5 „Temperature“ (inside) +5 to +40°C sensor ................................................. 24<br />

5.6 "Temperature" (inside) -25 to +75°C sensor ................................................... 25<br />

5.7 Connection of Power supply and control cables............................................ 26<br />

5.8 Connecting single drive ................................................................................. 27<br />

5.9 Mounting the contol panel ............................................................................. 28<br />

5.10 De-mounting the control panel ...................................................................... 28<br />

6. Commissioning .................................................................................................. 29<br />

6.1 Automatic presetting ..................................................................................... 29<br />

6.1.1 Password ................................................................................................. 29<br />

6.2 Changing the user language .......................................................................... 30<br />

6.3 Setting the product type ................................................................................ 31<br />

6.4 Allocating connected Sensors ....................................................................... 32<br />

6.5 Setting the time and date .............................................................................. 33<br />

7. Factory settings................................................................................................... 35<br />

8. Custom settings .................................................................................................. 37<br />

9. Technical data ...................................................................................................... 39<br />

10. User information ............................................................................................... 41<br />

11. Notes .................................................................................................................. 42<br />

932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 3


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

1. General<br />

4<br />

We reserve the right to carry out improvements<br />

With the <strong>Wisotronic</strong> <strong>dialog</strong> you now own a multifunctional sun protection control<br />

unit which can control various sun protection products (slat products, cloth<br />

products, roller shutters, etc.) intelligently in accordance with the respective<br />

weather conditions.<br />

You can either operate your sun protection products manually or leave the<br />

operation completely to the automatic control products. The <strong>Wisotronic</strong> <strong>dialog</strong><br />

protects your sunblind against harmful weather influences and offers extensive<br />

comfort and safety functions. The <strong>Wisotronic</strong> <strong>dialog</strong> can furthermore be operated<br />

via an EWFS radio remote control unit (1 or 8 channels), whereby the radio<br />

receiver is integrated in the control panel.<br />

The <strong>Wisotronic</strong> <strong>dialog</strong> evaluates the data for:<br />

® Wind,<br />

® Rain,<br />

® Brightness,<br />

® Internal and external temperature,<br />

and correspondingly controls the connected sun protection products, such as slat<br />

products (outside venetian blinds, internal venetian blinds), cloth products<br />

(awnings, pleated blinds), vertical venetian blinds, darkening units and roller<br />

shutters.<br />

932806B0•816758•7975k0•08.10.2004


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

2. For your safety<br />

2.1 Pictogram and symbol<br />

explanations<br />

We have developed, manufactured and tested the control system under<br />

observance of the fundamental safety requirements.<br />

Residual risks nevertheless remain!<br />

■ Therefore read these instructions before you install the control system.<br />

■ Please save these instructions for future use!<br />

The following warnings and notes which are intended to draw your attention to<br />

certain points can be applied to the control system itself or to the connected<br />

devices:<br />

Warning against dangerous electrical voltage!<br />

Electrostatic sensitive devices!<br />

Only for connection of the protective earth (PE) conductor!<br />

Only for connection of a shielded conductor!<br />

932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 5


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

6<br />

We reserve the right to carry out improvements<br />

Hierarchic warnings are used in these instructions.<br />

They are identified by a warning sign in the margin and graded hierarchically as<br />

follows:<br />

1. WARNING<br />

2. ATTENTION<br />

3. CAUTION<br />

WARNING<br />

ATTENTION<br />

CAUTION<br />

The term WARNING is used as a warning against immediate<br />

imminent danger.<br />

Death or serious injuries may result (damage to persons)<br />

The term ATTENTION is used as a warning against a possible<br />

imminent danger.<br />

Death, serious or minor injuries (damage to persons), damage to<br />

property or damage to the environment may result.<br />

The term CAUTION is used as an application<br />

recommendation.<br />

Damage to property may result from non-observance.<br />

In addition to the hierarchic warnings described above we use the following<br />

symbols:<br />

TIP<br />

■ This sign identifies<br />

This is used to mark text sections which contain additional<br />

explanations, information or hints.<br />

- Activities which you must carry out, or<br />

- Instructions which must be observed.<br />

932806B0•816758•7975k0•08.10.2004


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

2.2 Usage to the intended<br />

purpose<br />

2.3 Target group<br />

ATTENTION<br />

ATTENTION<br />

The control system allows the direct connection of a<br />

conventional sun protection drive. Alternatively several sun<br />

protection drives can be connected together via motor control<br />

units. Should you have any questions about connecting nonsun-protection<br />

devices, please obtain the approval of the<br />

manufacturer! The equipment is intended for the assembly in<br />

interiors.<br />

The approval of the manufacturer has to be obtained if the<br />

device is to be used to a purpose different to that described<br />

here. Usage which is not to the intended purpose can result in<br />

damage to the user or third parties as well as damage to the<br />

device itself, the connected devices or to the moving<br />

mechanical parts of the complete system.<br />

■ Therefore always use our product to the intended purpose only!<br />

These instructions are intended for persons who mount, wire or connect the<br />

<strong>Wisotronic</strong> <strong>dialog</strong> including all the required parts to the supply voltage. The user<br />

instructions (Art. No. 816757) are available for those persons who operate, set or<br />

commission the control system.<br />

ATTENTION<br />

Mounting, connection, commissioning or operation by<br />

persons who are not sufficiently qualified and informed can<br />

cause severe damage to the system or even damage to<br />

persons!<br />

■ Mounting and commissioning may therefore only be carried out by<br />

correspondingly trained specialists! This personnel must be able to recognize<br />

dangers which can be caused by the mechanical, electrical or electronic<br />

equipment!<br />

■ Persons who mount or connect the <strong>Wisotronic</strong> <strong>dialog</strong> must know and have<br />

understood the contents of these instructions.<br />

■ The <strong>Wisotronic</strong> <strong>dialog</strong> has been designed and constructed by us to be safe. All<br />

the necessary settings are carried out during the commissioning process. The<br />

system parameters only need to be modified if the behavior of the control<br />

system is to be adapted, a change has occurred at the sensor equipment or<br />

the <strong>Wisotronic</strong> <strong>dialog</strong> itself is replaced.<br />

ATTENTION<br />

States of danger, malfunctions and material damage to the<br />

system possible due to improperly executed mounting,<br />

connection, repair or maintenance work!<br />

■ Such work may only be carried out by the service department or by authorized<br />

qualified personnel!<br />

■ When carrying out maintenance or repair work only use such spare/<br />

replacement parts which are authorized by the system manufacturer.<br />

932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 7


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

2.4 Working safely<br />

2.5 Software version<br />

8<br />

We reserve the right to carry out improvements<br />

WARNING<br />

States of danger, malfunctions and material damage to the<br />

system due to the disconnection of connections during<br />

operation are possible!<br />

All the connections are required to ensure correct operation<br />

of the control system.<br />

■ Therefore always switch off the entire system before you connect or<br />

disconnect connecting lines.<br />

ATTENTION<br />

Danger to life and damage to property through sudden<br />

movements of mechanical units!<br />

■ If you want to carry out work at building facades at which motor-driven<br />

sunblinds are installed, switch off the sun protection system beforehand!<br />

Ensure that the system is secured sufficiently against unauthorized or<br />

unintentional activation.<br />

■ Ensure that suitable systems for protecting persons are used under all<br />

circumstances.<br />

■ Never place any objects in the area of movement of an automatically<br />

controlled mechanism (for example a ladder against a wall with articulated arm<br />

awning)!<br />

The following documents are available in addition to these instructions:<br />

® User <strong>guide</strong> Art. No.: 816757<br />

® Anschlusspläne für MSE, Netzteile und GA Art. 816 345 (German)<br />

These instructions were drawn up on the basis of the software version<br />

19531103<br />

Please refer to Section 8 of the user <strong>guide</strong> for further information about<br />

establishing the software version of your device.<br />

932806B0•816758•7975k0•08.10.2004


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

3. Mounting<br />

3.1 Procedure<br />

CAUTION<br />

States of danger and malfunctions possible!<br />

The <strong>Wisotronic</strong> <strong>dialog</strong> and its supplementary components<br />

may only be operated in a built-in state or at the specified<br />

mounting sites. If this is not observed, malfunctions or states<br />

of danger at the system are possible. Any claims to warranty<br />

or guarantee are definitely lost.<br />

Carry out the following points in the specified order:<br />

■ First specify at which points the individual components are to be mounted.<br />

Use the specifications in this section and in the data sheets of the sensors to<br />

this purpose.<br />

■ Then determine which cables are required to interconnect the components.<br />

Use the "Wiring diagrams" section to this purpose.<br />

■ Lay the required cables. Do not use cables with larger cross-sections than<br />

specified. It is best to use conduits to lay the motor cables.<br />

■ Mount and wire the individual components.<br />

■ Check the wiring before you switch on the supply voltage of the control<br />

system.<br />

■ Then carry out commissioning. Only then is the control system ready for use.<br />

The steps required for commissioning are described in detail in the "User<br />

<strong>guide</strong>" manual. Please refer to it.<br />

■ Check the correct direction of movement of the sunblind by operating the "Up"<br />

and "Down" buttons at the control system.<br />

Check the correct function of the connected sensors<br />

■ Check the measured value display of the temperature, humidity and<br />

brightness for plausible values.<br />

■ Check whether the wind speed display changes when the wind vane is<br />

turned.<br />

■ Activate the rain control (if sensor connected) and check whether the control<br />

system reacts to rain (wet the sensor area with water).<br />

■ Then adapt the behavior of the system to the ambient conditions and for<br />

special requirements. Also use the "User <strong>guide</strong>" to this purpose. Chapter 7 of<br />

this installation <strong>guide</strong> furthermore contains a table with all the available setting<br />

steps (parameters), their limits and the factory settings.<br />

■ If you have changed the factory settings, record the new values of the system<br />

in the table (Chapter 9) after you have completed all the work.<br />

ATTENTION<br />

Mount electrical devices so that they can be accessed easily!<br />

(VDE 0100)<br />

932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 9


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

3.2 <strong>Installation</strong><br />

3.2.1 Flush-type mounting<br />

3.2.2 Surface-type mounting<br />

10<br />

We reserve the right to carry out improvements<br />

The <strong>Wisotronic</strong> <strong>dialog</strong> is designed for installation in a flush-mounting box, a<br />

surface-mounting housing is also available. The device is to be mounted in a dry<br />

and easily accessible place. Under no circumstances may it mounted outdoors,<br />

may not be subjected to direct sun irradiation or may not be mounted directly over<br />

a radiator. After installation in the flush-mounted box the bottom plate of the<br />

supply unit must be flush with the wall. Otherwise the control panel may not latch<br />

in correctly. The flush-mounted box should therefore be embedded horizontally in<br />

the plaster.<br />

■ After the cables have been connected, the power unit is fastened in the flushmounted<br />

box with the enclosed screws. Note: Do not tighten the screws too<br />

much, because the bottom plate may be damaged! Ensure that no connecting<br />

cables are pinched during installation.<br />

Fig. 3-1: <strong>Installation</strong> in flush-mounted box<br />

■ Use the same procedure for the surface-mounted housing.<br />

Fig. 3-2: <strong>Installation</strong> in surface-mounted housing<br />

CAUTION<br />

Bottom plate<br />

Power unit<br />

Flushmounted<br />

box<br />

Use only the supplied screws to mount the bottom plate!<br />

Screw all the screws<br />

in completely until the screw heads are flush with the bottom<br />

plate.<br />

Otherwise short-circuits are possible when the control panel<br />

is clipped on!<br />

932806B0•816758•7975k0•08.10.2004


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

The radio receiver has been integrated into the control panel. The range of radio<br />

control systems is limited by the statutory regulations on radio systems and by<br />

structures. When planning the system ensure that the radio reception is<br />

sufficient. This applies in particular if the transmitter and receiver are positioned in<br />

different rooms and the radio signal has to penetrate walls and ceilings. The control<br />

system should not be installed directly near metallic surfaces (steel girders,<br />

fire doors).<br />

■ Therefore check the function of the receiver before finally carrying out<br />

mounting.<br />

Powerful local transmission systems (for example, baby intercom or neighboring<br />

transmitters) whose transmission frequency is identical to that of the control<br />

system, can interfere with the reception.<br />

The control panel can be mounted either in a flush-mounting box or directly on the<br />

wall. When specifying the mounting height ensure that the display can be read<br />

easily (recommendation: Bottom edge of the device approx. 1.35 m above top<br />

edge of completed flooring).<br />

TIP<br />

A temperature sensor is integrated in the control panel.<br />

Therefore do not mount the control panel where influencing<br />

through sources of heat is to be expected (sun radiation,<br />

radiators, outer wall). This prevents incorrect measurements!<br />

Switch off the operating voltage before you mount and<br />

connect the control panel. Pulling off the plug-and-socket<br />

connections during operation can damage the device.<br />

■ Mount the bottom plate on a flush-mounted switch box or directly on the wall.<br />

Use suitable mounting material. The oblong holes allow the bottom plate to be<br />

aligned absolutely horizontally.<br />

TIP<br />

Ensure that the mounting surface does not have any<br />

unevenness. Otherwise the bottom plate could be bent out of<br />

shape during mounting so that the control panel cannot latch<br />

in correctly!<br />

932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 11


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

3.3 "Wind/Photo" sensor<br />

12<br />

We reserve the right to carry out improvements<br />

The sensor detects the wind speed and the sun intensity.<br />

TIP<br />

Mount the "Wind/Photo/Radio clock" sensor using the<br />

enclosed mounting bracket.<br />

3 m or 10 m cables are connected fixed to the sensor. If the<br />

cable length is not sufficient, a branching box is required. The<br />

total cable length from the sensor to the central control unit<br />

may amount to a max. of 100 m in case of interference-proof<br />

laying and under use of twisted-pair cables. Further<br />

information can be found in the user and installation <strong>guide</strong> of<br />

the sensor.<br />

■ The sensor must be mounted upright with a maximum inclination of ±2°.<br />

■ The photo diodes must not be aligned to the compass directions but rather to<br />

the shading building facades.<br />

■ Mount the sensor to be easily accessible at the highest point of the roof<br />

structure or of the conservatory.<br />

■ Do not mount the sensor sheltered from the wind because the wind<br />

evaluation may otherwise be impaired.<br />

■ A photo diode has to be connected to the terminal "Photo 1" of the <strong>Wisotronic</strong><br />

<strong>dialog</strong> - otherwise the dawn/dusk control does not have any function.<br />

■ Photo diode 1 (figure below) controls the dawn/dusk control. The sensor must<br />

therefore be mounted so that this photo diode cannot be influenced during the<br />

night by street or garden light or other external light sources (such as<br />

flashlights).<br />

Fig. 3-3: Alignment of the individual photo diodes<br />

932806B0•816758•7975k0•08.10.2004


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

3.3.1 Allocation/alignment of<br />

the photo diodes<br />

The sensor may not be shaded by trees, buildings, etc. because incorrect<br />

functions may otherwise result during the sun evaluation (take the course of the<br />

sun during the day into account).<br />

Fig. 3-4: Plants or buildings can shade the "Photo" sensor in the course of the day<br />

The numbers 1 to 3 are allocated in our works to the four photo diodes, see<br />

Fig. 3-3. The allocation of the photo diodes to the individual functions of the<br />

<strong>Wisotronic</strong> <strong>dialog</strong> at a later point becomes much easier, if you connect the photo<br />

diodes to the <strong>Wisotronic</strong> <strong>dialog</strong> in accordance with their numbers. Additional<br />

information can be found in the user and installation <strong>guide</strong> of the sensor.<br />

TIP<br />

"Photo" sensor<br />

is shaded<br />

Position of the sun<br />

changes in the course of the day<br />

"Photo" sensor<br />

is shone on<br />

When selecting the mounting site you must furthermore<br />

ensure that the sensor is subjected to the same conditions<br />

(wind, sun) as the sunblind to be controlled. If this is not the<br />

case, the measured values are falsified and your sunblind may<br />

not be controlled correctly.<br />

Technical data:<br />

Measuring range Windspeed 0 - 25m/s<br />

Measuring range brightness 0 - 99 klx<br />

Signal: Wind speed 10m/s = 21Hz<br />

Brightness 1klx = 80µA<br />

Article numbers:<br />

Wind/Photo" sensor (1 facade), black<br />

with 3.5 m connecting cable and angle bracket 623 011<br />

"Wind/Photo" (1 facade) sensor, black<br />

10 m connecting cable and angle bracket 623 022<br />

"Wind/Photo" sensor (1 facade), black,<br />

10 m connecting cable and angle bracket 623 009<br />

Mounting accessories:<br />

Standpipe L = 35cm, ÿ = 20mm, wall mounting,<br />

wall distance 150 mm 632 075<br />

Standpipe L = 100cm, ˇ = 20mm, wall mounting,<br />

wall distance 150 mm 632 085<br />

Adapter for standpipes with ø 50mm 632 095<br />

932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 13


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

3.4 "Photo" (180°) sensor The "Photo" (180°) sensor is used when a wind sensor is not needed, for example<br />

at an inside sun protection system. The sensor allows light-dependent controlling<br />

of sun protection products such as internal venetian blinds, pleated blinds or<br />

external venetian blinds. It is mounted to an angle bracket and fastened with it on<br />

the facade outside. Exact information can be found in the user and installation<br />

instructions of the sensor.<br />

3.5 "Rain" (capacitive) sensor<br />

14<br />

We reserve the right to carry out improvements<br />

Technical data:<br />

Measuring range brightness 0 - 99 klx<br />

Signal: 1klx = 80µA<br />

Article number:<br />

"Photo" (180°) Sensor, black,<br />

with 3.5 m connecting cable and angle bracket 623 016<br />

In case of precipitation in the form of drizzle, rain, hail or snow the "Rain" sensor<br />

triggers a switching signal. The switching threshold of the device is set in our<br />

works to a typical value and can be adapted after commissioning by the user to<br />

the requirements of his sun protection and the local climatic conditions. If the<br />

sensor area is dry, the switching signal is canceled after an adjustable OFF delay.<br />

The sensor area is heated. The temperature of the sensor area is maintained<br />

constantly to approx. 40°C and thus prevents triggering at high humidity as well<br />

as icing at minus temperatures. After detection of precipitation the sensor area<br />

dries quickly thanks to the heating.<br />

Mount the sensor using the enclosed fastening material at an easily accessible<br />

position near your sun protection. In order to ensure optimal functioning, the<br />

precipitation must fall unhindered on the sensor area from all directions. The<br />

sensor must be cleaned quarterly.<br />

The holding plate attached to the sensor creates the angle required for the water<br />

to flow from the sensor area. This angle should not be changed by the fastening<br />

procedure. Exact information can be found in the corresponding user and<br />

installation instructions of the sensor.<br />

Note: A power supply unit is required to heat the sensor.<br />

Technical data:<br />

Measured value Precipitation Yes/No<br />

Activation time Non-delayed, sensitivity can be<br />

set<br />

Deactivation time Delayed, 1 - 10 min., adjustable<br />

Article numbers:<br />

"Rain" sensor (capacitive) 1002 325<br />

Suitable power supply unit in MCU housing 629 065<br />

Flush-type mounting cover for power supply unit 317 160<br />

Fastening set for pipe mounting 1003 255<br />

932806B0•816758•7975k0•08.10.2004


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

3.6 "Temperature" (outside)<br />

sensor<br />

3.7 "Temperature" (inside)<br />

sensor 5 to 40°C<br />

3.8 "Temperature" (inside)<br />

sensor -25 to +75°C<br />

The sensor is used to detect the outside temperature precisely and is required,<br />

for example, for ice monitoring. The sensor should be mounted as far as possible<br />

on the northern side of a building and may not be subject to direct sunshine in<br />

order to provide correct measured values to the control system. Exact mounting<br />

information can be found in the user and installation <strong>guide</strong> of the sensor.<br />

Technical data:<br />

Measuring range -25 to +75°C<br />

Signal 1kHz = 75°C<br />

Article numbers:<br />

"Temperature" (outside) sensor 628 145<br />

Fastening set for pipe mounting 1003 255<br />

The sensor for inside temperature is used to detect the room temperature<br />

precisely, for example in a conservatory. The sensor should ideally be mounted in<br />

approx. 1 m height, in the correct position and free from air draft. The sensor may<br />

not be subjected to direct sunshine in order to supply correct measured values to<br />

the control system. Exact information can be found in the user and installation<br />

<strong>guide</strong> of the sensor.<br />

Technical data:<br />

Measuring range +5 to +40°C<br />

Signal 1 kHz = 75°C<br />

Article number:<br />

"Temperature" (inside) sensor 5 to 40°C 623 038<br />

Sensor for inside temperature as above, however with extended measuring<br />

range.<br />

Technical data:<br />

Measuring range -25 to +75°C<br />

Signal 0.5 kHz = 25°C<br />

Article number:<br />

"Temperature" (inside) sensor -25 to +75°C 628 146<br />

TIP<br />

A sensor for the room temperature is already installed in the<br />

control panel. This is called the "internal" sensor. One sensor<br />

can additionally be connected to terminal strip X3 ("external"<br />

sensor).<br />

932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 15


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

3.9 Connecting sensors<br />

16<br />

We reserve the right to carry out improvements<br />

The <strong>Wisotronic</strong> <strong>dialog</strong> recognizes automatically whether and which sensors are<br />

connected. The <strong>Wisotronic</strong> <strong>dialog</strong> cannot control your sun protection system<br />

optimally and display measured values until all the required sensors have been<br />

connected.<br />

CAUTION<br />

f no sensors are connected, you cannot damage anything at<br />

the control system. Only the current room temperature is<br />

then displayed. However, take into consideration that in this<br />

case the sun protection control system cannot operate<br />

correctly, so that your sunblind could be damaged!<br />

Only the sensors described below may be connected to the <strong>Wisotronic</strong>.<br />

Otherwise the approval of the manufacturer is to be obtained.<br />

The following sensor inputs are available:<br />

1 x "Temperature" (external)<br />

1 x "Wind"<br />

1 x "Rain"<br />

3 x "Photo"<br />

Sensors may not be connected in parallel!<br />

932806B0•816758•7975k0•08.10.2004


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

4. Connectioninformation<br />

ATTENTION<br />

TIP<br />

ATTENTION<br />

A line-side disconnecting device is to be provided in the fixed<br />

installation in order to disconnect the <strong>Wisotronic</strong> <strong>dialog</strong> from<br />

the supply voltage (power breaker conforming to EN 60335-1,<br />

Section 25.2, for example, miniature circuit-breaker). Any<br />

associated motor control units (MCU) and their consumers<br />

may not be protected against short circuits by means of this<br />

miniature circuit-breaker.<br />

The <strong>Wisotronic</strong> <strong>dialog</strong> must be separated from the supply<br />

voltage before the housing is opened!<br />

A screwdriver size 0 is required to tighten the sensor<br />

terminals. Do not use a battery-driven screwdriver!<br />

EN 60335-1 is to be applied when connecting the power<br />

supply cable. (Wire cross-section, type of conductor, additional<br />

securing against loosening, strain relief, wire end ferrules<br />

at stranded conductors, circuit-breakers).<br />

The voltage drop diagrams of the looped-through motor control<br />

units are to be observed with regard to the looping<br />

through of the supply voltage.<br />

The external +12V voltages provided by the <strong>Wisotronic</strong> <strong>dialog</strong><br />

are provided exclusively for works-own sensors.<br />

In accordance with VDE 0022 responsibility for observance of<br />

the utility-company or VDE regulations lies with the operator<br />

and the person installing.<br />

The lines specified in the line diagram are minimum crosssections<br />

designed for copper, without consideration of the<br />

length and the resulting voltage drops.<br />

If lines are laid outdoors, the corresponding VDE regulations<br />

are to be observed. In addition the lines must be suitable for<br />

outdoor use.<br />

The distance to the power cables must amount to at least 20<br />

cm. Laying parallel to live lines is to be avoided! The<br />

insulation voltage between the screen and conductors must<br />

be > 2.5 kV. The lines should be laid in one piece.<br />

By default commercial light-current cables, for example<br />

JY(St)Y, are for pushbutton, sensor and network lines. As a<br />

rule this is sufficient with regard to external EMC influences,<br />

for example in living areas at line lengths up to 50 m. Optimum<br />

protection against external EMC influences is, on the<br />

other hand, provided by high-quality lines with braided screen<br />

(not foil screen!) and closely twisted pair conductors. The<br />

longer the line, the greater the interference susceptibility!<br />

Therefore only lay high-quality lines at line lengths above 50<br />

m up to a max. of 100 m!<br />

If the sunblind is moved down for maintenance, repair,<br />

cleaning, etc., the complete sun protection system must be<br />

shut down afterwards by means of the line-side disconnecting<br />

device.<br />

932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 17


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

4.1 Handling of the<br />

spring-load<br />

terminals<br />

4.2 Handling of the<br />

screw/clamp type<br />

terminals<br />

18<br />

We reserve the right to carry out improvements<br />

WARNING<br />

Work on the 230V Power supply may only be carried out by<br />

qualified electrical personnel (in accordance with VDE 0100).<br />

1<br />

Fig. 4-1: Connecting and loosening the cable connections<br />

The power supply cable, the drive and the central control unit are connected with<br />

spring-load terminals: After the conductor has been bared, press it into the<br />

terminal (1) until the insulation of the conductor immerses into the terminal and<br />

the conductor is held firmly in the terminal (2). In order to loosen the connection,<br />

press in the corresponding release button with a screwdriver until it stops and<br />

then pull the conductor out of the terminal (3).<br />

The connections of the sensor are realized as screw/clamp-type terminals. In<br />

order to facilitate connecting the terminal blocks can be removed and the<br />

conductors then connected. Use a screwdriver size 0 to this purpose. After<br />

connecting has been completed, the terminals are put back on.<br />

2<br />

932806B0•816758•7975k0•08.10.2004<br />

3


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

5. Wiring diagrams<br />

Terminal strip X1 For connecting<br />

the power supply cable 230V AC<br />

Terminal strip X3 For connecting<br />

a external "Temperature" sensor<br />

Fig. 5-1: Terminals of the <strong>Wisotronic</strong> <strong>dialog</strong><br />

1 2 3 4 5 6<br />

X1<br />

X2<br />

1 2 3 4<br />

X4<br />

X3 X5<br />

Terminal strip X4 For connecting<br />

the "Photo" sensors<br />

ATTENTION<br />

Terminal strip X2<br />

Isolated output for connecting a<br />

"Geschossansteuerverteiler",<br />

motor control units (MCU)<br />

or a drive.<br />

Fuse (accessible after cover has<br />

been opened).<br />

Note: The device inside does not<br />

contain any parts which can be<br />

maintained. In case of a malfunction<br />

the installed fuse may<br />

only be replaced by qualified<br />

electrical personnel.<br />

Terminal strip X5 For connecting<br />

the "Wind" and "Rain" sensors<br />

Lay the cables for the drive and power supply from above<br />

into the distributor box and the cables for the sensors from<br />

below!<br />

Cables with supply voltage have to be laid at least 8 mm<br />

away from sensor cables.<br />

If 24 V control cables are connected to terminal strip X2,<br />

these have to be laid at least 8 mm away from the 230V<br />

cables. Otherwise the 24 cables have to be double-insulated<br />

(for example with silicone-rubber insulation)!<br />

932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 19


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

5.1 "Wind/Photo" sensor<br />

20<br />

Photo 3<br />

Photo 2<br />

Photo 1<br />

Fig. 5-2: Wiring diagram „Wind/Photo“ sensor<br />

We reserve the right to carry out improvements<br />

+12V DC<br />

+12V DC<br />

"Wind/Photo" sensor<br />

Photo 1<br />

Photo 1<br />

Photo 2<br />

Photo 2<br />

Photo 3<br />

Photo 3<br />

0V<br />

Wind<br />

0V<br />

Wind<br />

X3 1 2 3 1 2 3 4 1 2 3 4<br />

X4<br />

*Use twisted pair cable, interference-proof laying.<br />

See section "Connection information"!<br />

Branching box<br />

mounted<br />

by customer<br />

JY(St)Y4x2x0,8mmø<br />

max. length of line 100 meters*<br />

X5<br />

932806B0•816758•7975k0•08.10.2004


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

5.2 "Photo" (180°) sensor<br />

Photo 3<br />

Photo 2<br />

Photo 1<br />

Fig. 5-3-: Wiring diagram „Photo“ (180°) sensor<br />

+12V DC<br />

+12V DC<br />

X4<br />

"Photo" (180°)<br />

sensor<br />

Photo 1<br />

Photo 1<br />

Photo 2<br />

Photo 2<br />

Photo 3<br />

Photo 3<br />

X3 1 2 3 1 2 3 4 1 2 3 4<br />

*Use twisted pair cable, interference-proof laying.<br />

See section "Connection information"!<br />

Branching box<br />

mounted<br />

by customer<br />

JY(St)Y2x2x0,8mmø<br />

max. length of line 100 meters*<br />

932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 21<br />

X5


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

5.3 „Rain“ (capacitive) sensor<br />

Fig. 5-4: Wiring diagram „Rain“ (capacitive) sensor<br />

22<br />

4xAWG 24C UL<br />

(UV - resistent)<br />

JY(St)Y2x2x0,8mmø<br />

max. length of<br />

line 100 meters*<br />

1 2 3 4<br />

X4<br />

We reserve the right to carry out improvements<br />

"Rain" (capacitive)<br />

sensor<br />

Branching box<br />

mounted<br />

by customer<br />

H05RR-F4G0,75mm 2 sw<br />

Regen<br />

0V<br />

X3 1 2 3 1 2 3 4 1 2 3 4<br />

X5<br />

*Use twisted pair cable, interference-proof laying.<br />

See section "Connection information"!<br />

N L1<br />

Power supply for<br />

"Rain" sensor<br />

NYM-J 3x1,5 mm 2<br />

L<br />

N<br />

Power<br />

supply<br />

230V AC<br />

932806B0•816758•7975k0•08.10.2004


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

5.4 „Temperature“ (outside) sensor<br />

JY(St)Y2x2x0,8mmø<br />

max. length of<br />

line 100 meters*<br />

X3<br />

+12V<br />

+12V<br />

0V<br />

Temp<br />

X4<br />

*Use twisted pair cable, interference-proof laying.<br />

See section "Connection information"!<br />

Fig. 5-5: Wiring diagram „Temperature“ (outside) sensor<br />

ϑ<br />

T<br />

°C<br />

"Temperature"<br />

(outside) sensor<br />

4xAWG 26C UL<br />

(UV - resistent)<br />

Branching box,<br />

mounted by customer<br />

1 2 3 1 2 3 4 1 2 3 4<br />

932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 23<br />

X5


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

5.5 „Temperature“ (inside) +5 to +40°C sensor<br />

24<br />

JY(St)Y2x2x0,8mmø<br />

max. length of<br />

line 100 meters*<br />

X3<br />

Fig. 5-6: Wiring diagram „Temperature“ (inside) +5 to -40°C sensor<br />

+12V<br />

0V<br />

Temp<br />

We reserve the right to carry out improvements<br />

ϑ<br />

+12V<br />

0V<br />

+ ⊥<br />

↓<br />

"Temperature" (inside) +5 to +40°C<br />

sensor<br />

JY(St)Y2x2x0,8mmø<br />

Branching box<br />

mounted by customer<br />

1 2 3 1 2 3 4 1 2 3 4<br />

X4<br />

*Use twisted pair cable, interference-proof laying.<br />

See section "Connection information"!<br />

X5<br />

932806B0•816758•7975k0•08.10.2004


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

5.6 "Temperature" (inside) -25 to +75°C sensor<br />

X1<br />

JY(St)Y2x2x0,8mmø<br />

max. length of<br />

line 100 meters*<br />

X3<br />

+12V<br />

Fig. 5-7: Wiring diagram "Temperature" (inside) -25 to +75°C sensor<br />

ϑ<br />

+12V<br />

0V<br />

0V<br />

Temp<br />

"Temperature"<br />

(inside) -25 to +75°C sensor<br />

JY(St)Y2x2x0,8mmø<br />

Branching box<br />

mounted by customer<br />

X4<br />

*Use twisted pair cable, interference-proof laying.<br />

See section "Connection information"!<br />

X52 5<br />

932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 25


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

5.7 Connection of Power supply and control cables<br />

Fig. 5-8: Power supply and control cables<br />

26<br />

Power supply<br />

230 V AC<br />

50Hz / 16A<br />

NYM-J 3x 1,5mm 2<br />

We reserve the right to carry out improvements<br />

To "Geschossansteuerverteiler" (power supply)<br />

or to the motor control units (MCU).<br />

Refer to the documentation "Anschlusspläne",<br />

(german) Art.-Nr. 816 345<br />

P<br />

1 2 3 4 5 6<br />

X1<br />

ACHTUNG<br />

PE<br />

PE<br />

N<br />

N<br />

L<br />

L<br />

P E<br />

X2<br />

F1 3,15 AT<br />

1<br />

2 3 4<br />

If 24 V control cables are connected to terminal strip X2, these<br />

have to be laid at least 8 mm away from the 230V cables.<br />

Otherwise the 24V cables have to be double-insulated (for<br />

example with silicone-rubber insulation)!<br />

E<br />

932806B0•816758•7975k0•08.10.2004


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

5.8 Connecting single drive<br />

Power supply<br />

230 V AC<br />

50Hz / 16A<br />

NYM-J 3x 1,5mm 2<br />

Fig. 5-9: Connecting single drive<br />

H05RR-F4G0,75mm 2 sw<br />

1 2 3 4 5 6<br />

X1<br />

PE<br />

PE<br />

N<br />

N<br />

L<br />

L<br />

F1 3,15 AT<br />

932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 27<br />

1<br />

1<br />

gnge<br />

bl<br />

br<br />

P<br />

X2<br />

1<br />

Motor 1<br />

M1~<br />

2<br />

1<br />

3<br />

3<br />

3<br />

sw<br />

2 Plug connection<br />

2<br />

2 3 4<br />

Caution! Only one drive may be<br />

connected. The drive is damaged<br />

in case of parallel connections!


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

5.9 Mounting the contol panel<br />

5.10 De-mounting the control<br />

panel<br />

28<br />

We reserve the right to carry out improvements<br />

■ Switch off the supply voltage of the <strong>Wisotronic</strong>.<br />

■ Insert the connecting cables into the plug-and-socket connection provided at<br />

the control panel. Note: Frequent inserting and removal of the plug-and-socket<br />

connection can damage it!<br />

■ Then clip the control panel onto the supply unit.<br />

■ Switch on the supply voltage of the <strong>Wisotronic</strong>.<br />

Fig. 5-10: Mounting the control panel<br />

■ Switch off the supply voltage of the <strong>Wisotronic</strong>.<br />

■ In order to remove the control panel, pull simultaneously at the side vent slots<br />

at the control panel.<br />

■ Repeat at the opposite side and remove the control panel.<br />

■ Loosen the plug-and-socket connection<br />

Pull simultaneously<br />

carefully here<br />

Fig. 5-11: Removing the control panel<br />

Control panel<br />

Catch<br />

Power unit<br />

Insert connecting<br />

line here<br />

932806B0•816758•7975k0•08.10.2004


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

6. Commissioning<br />

6.1 Automatic presetting<br />

6.1.1 Password<br />

TIP<br />

Before the commissioning the required sensors have to be<br />

connected!<br />

As soon as the supply voltage is activated, the <strong>Wisotronic</strong> <strong>dialog</strong> automatically<br />

carries out the presettings for articulated arm awnings. This is the sun protection<br />

product which is most sensitive to weather influences. After approx. 10 seconds<br />

the current indoor temperature is display and the symbols for the manual<br />

operation UP / DOWN are shown in the display. The connected sunblind can now<br />

be moved manually to try it out.<br />

In order to open the service settings you must enter the password:<br />

■ Turn the function dial until the following display appears:<br />

Serviceeinstellungen<br />

932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 29<br />

{<br />

■ Select the menu item (button {). The following display appears:<br />

Zugangscode<br />

eingeben<br />

0000<br />

* + | }<br />

You now have to enter a password (if you have already entered a password, this<br />

menu is no longer displayed. Instead the "Product” menu is displayed<br />

immediately). Enter the password "5858":<br />

■ ■ Press the button + momentarily until the first number of the password is<br />

displayed at the first position. Change to the next position by pressing the<br />

button * momentarily. Enter all the numbers by the same method and then<br />

press the button {. The following display appears:<br />

Produkt<br />

{ }<br />

If the incorrect password was entered, 0000 is displayed again and you have<br />

to enter the password again.<br />

■ In order to exit the menu press the }button twice consecutively. This<br />

completes the process.


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

6.2 Changing the user<br />

language<br />

30<br />

We reserve the right to carry out improvements<br />

The default setting of the user language is "Deutsch". Proceed as follows in order<br />

to change the user language to "English":<br />

■ Turn the function dial until the following display appears:<br />

Serviceeinstellungen<br />

{<br />

■ Select the menu item (button {). The following display appears:<br />

Produkt<br />

{ }<br />

■ Turn the function dial until the following display appears:<br />

Sprache<br />

{ }<br />

■ Select the menu item (button {). The following display appears:<br />

Sprache<br />

Deutsch<br />

— + | }<br />

■ Change the settings by using the buttons — + and then press the button<br />

| (save) If you want to exit the menu without saving the changes, press the<br />

}button twice consecutively. This completes the process.<br />

932806B0•816758•7975k0•08.10.2004


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

6.3 Setting the product type<br />

You can now set your product (slat products, cloth products, roller shutters, etc.)<br />

in order to adapt the <strong>Wisotronic</strong> <strong>dialog</strong> optimally to your requirements.<br />

Each of these products has different properties. This means that they also react<br />

differently to wind, require other turn times and runtimes or are perhaps<br />

positioned inside and therefore do not require rain and wind protection, etc.. So<br />

that you do not have to enter all the product-dependent setting values and limits<br />

whenever you set a product in the <strong>Wisotronic</strong>, <strong>Wisotronic</strong> <strong>dialog</strong> carries out this<br />

work for you. The required values are already stored for many products. All the<br />

product-dependent setting values are programmed by only pressing a button.<br />

Let us assume that you have connected outside venetian blinds and now want to<br />

set this product type at the <strong>Wisotronic</strong> <strong>dialog</strong>. Proceed as follows in order to do<br />

so:<br />

■ Turn the function dial until the following display appears:<br />

Service<br />

settings<br />

932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 31<br />

{<br />

■ Select the menu item (button {). The following display appears:<br />

Product<br />

{ }<br />

■ Select this menu item (button {). The following display appears:<br />

Product<br />

Product type<br />

Fold.arm awning<br />

— + | }<br />

■ Change the product type by using the buttons — + and then press the<br />

button | (save). If you want to exit the menu without saving the changes,<br />

press the }button twice consecutively. This completes the process.<br />

■ Quit the setting menu by pressing the } button twice.<br />

■ De-energize the <strong>Wisotronic</strong> for approx. 5 seconds at the line-side fuse and<br />

then switch it on again. This blocks the access to the service settings again so<br />

that they can only be opened again by entering the password.<br />

ATTENTION<br />

The basic settings of the controlled products have to be<br />

adapted to the manufacturer specifications, if necessary!


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

6.4 Allocating connected<br />

Sensors<br />

32<br />

We reserve the right to carry out improvements<br />

The “Temperature” sensors connected to the <strong>Wisotronic</strong> <strong>dialog</strong> now have to be<br />

allocated. In the process you specify which sensor is used to control the<br />

temperature-specific functions.<br />

The <strong>Wisotronic</strong> disposes of a temperature sensor built into the device with which<br />

the required measured values can be recorded. Alternatively an additional sensor<br />

input is available. Either a sensor for interior temperature or for external<br />

temperature can be connected here. You can set which sensor is to be evaluated<br />

by the temperature control:<br />

■ Turn the function dial until the following display appears:<br />

User<br />

settings<br />

{<br />

■ Select the menu item (button {). The following display appears:<br />

Sun<br />

control<br />

{ }<br />

■ Turn the function dial until the following display appears:<br />

Temperature<br />

control<br />

{ }<br />

■ Select the menu item (button {). The following display appears:<br />

Temperature<br />

control<br />

OFF<br />

— + | }<br />

■ Turn the function dial until the following display appears:<br />

Allocation<br />

temp. sensor<br />

External<br />

— + | }<br />

If the value “Internal” is set, the temperature control evaluates the sensor built<br />

into the device. If the value “External” is set, the temperature control evaluates<br />

the sensor which is connected externally.<br />

TIP<br />

It is not possible to evaluate both sensors!<br />

932806B0•816758•7975k0•08.10.2004


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

6.5 Setting the time and date<br />

■ Change the settings by using the buttons — + and then press the button |<br />

(save). If you want to exit the menu without saving the changes, press the<br />

}button twice consecutively. This completes the process.<br />

Commissioning is completed when the sensors are allocated.<br />

A complete overview of all the functions of the <strong>Wisotronic</strong> <strong>dialog</strong> can be found in<br />

the corresponding user instructions. Please refer to it in order to adapt the control<br />

system optimally to your requirements.<br />

TIP<br />

After you have carried out your settings and have completed<br />

them, de-energize the device for approx. 5 seconds and then<br />

switch it on again. This blocks the access to the service<br />

settings again so that they can only be opened again by<br />

entering the password. This ensures that unauthorized<br />

persons do not have access to the service settings!<br />

If the date and time are not displayed correctly, you can correct this simply:<br />

■ Turn the function dial until the following display appears:<br />

User<br />

settings<br />

932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 33<br />

{<br />

■ Select the menu item (button {). The following display appears:<br />

Sun<br />

control<br />

{ }<br />

■ Turn the function dial until the following display appears:<br />

Date / Time<br />

{ }<br />

■ The following date and time displays are examples and may deviate from the<br />

display on your <strong>Wisotronic</strong>. Select the menu item (button {). The following<br />

display appears:<br />

Date / Time<br />

Time<br />

15:00<br />

— + | }


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

34<br />

We reserve the right to carry out improvements<br />

■ Set the current time by using the buttons — + and then press the button |<br />

(save)<br />

■ Turn the function dial until the following display appears:<br />

Date / Time<br />

Year<br />

2004<br />

— + | }<br />

■ Set the current year by using the buttons — + and then press the button |<br />

(save)<br />

■ Turn the function dial until the following display appears:<br />

Date / Time<br />

Month<br />

July<br />

— + | }<br />

■ Set the current month by using the buttons — + and then press the button<br />

| (save)<br />

■ Turn the function dial until the following display appears:<br />

Datum / Uhrzeit<br />

Day<br />

23<br />

— + | }<br />

■ Set the current day by using the buttons — + and then press the button |<br />

(save).<br />

■ Turn the function dial until the following display appears:<br />

Date / Time<br />

Weekday<br />

Friday<br />

— + | }<br />

■ Set the current weekday by using the buttons — + and then press the<br />

button | (save). Quit the setting menu by pressing the } button.<br />

This completes the process.<br />

932806B0•816758•7975k0•08.10.2004


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

7. Factory settings<br />

Setting step Unit<br />

Sun control<br />

Fig. 7-1: Factory settings (user settings)<br />

Articulated<br />

arm<br />

awning<br />

Conserv.-/<br />

Facadeawning<br />

User settings<br />

Outside<br />

venetian<br />

blind<br />

Roller<br />

shutter<br />

Pleated<br />

blind<br />

Inside<br />

venetian<br />

blind<br />

Sun control ON/OFF ON/OFF ON ON ON OFF ON ON<br />

Limit UP klx 30 30 15 30 30 30<br />

Delay UP min 10 10 20 10 10 10<br />

Limit OPEN klx --- --- --- --- --- ---<br />

Delay OPEN min 0 0 0 0 0 0<br />

Limit DOWN klx 50 50 35 50 50 50<br />

Delay DOWN min 5 5 2 5 5 5<br />

Position DOWN % 100 100 100 100 100 100<br />

Angle DOWN<br />

Dawn/dusk control<br />

Degrees 0 0 38 0 0 38<br />

Dawn/dusk control ON/OFF OFF OFF OFF ON OFF OFF<br />

Limit UP lx 30 30 30 30 30 30<br />

Limit DOWN lx 80 80 80 80 80 80<br />

Angle DOWN<br />

Temperature control<br />

Degrees 0 0 80 0 0 80<br />

Temperature control ON/OFF OFF OFF OFF OFF OFF OFF<br />

Direct control<br />

Operating mode<br />

Enable sun Direct control Direct control Direct control Direct control Direct control Direct control<br />

Limit UP/OFF ° C 22 22 22 22 22 22<br />

Limit DOWN/ON<br />

Rain monitoring<br />

° C 26 26 26 26 26 26<br />

Rain monitoring<br />

Timer switch<br />

ON/OFF ON ON OFF OFF OFF OFF<br />

Timer switch ON/OFF OFF OFF OFF OFF OFF OFF<br />

Mo - Fr UP hrs:min 18:00 18:00 8:00 8:00 8:00 8:00<br />

Mo - Fr DOWN hrs:min 8:00 8:00 22:00 22:00 22:00 22:00<br />

Sa - Su UP hrs:min 18:00 18:00 8:00 8:00 8:00 8:00<br />

Sa - Su DOWN hrs:min 8:00 8:00 22:00 22:00 22:00 22:00<br />

Angle DOWN<br />

Comfort timer<br />

Degrees 0 0 80 0 0 80<br />

Comfort timer ON/OFF OFF OFF OFF OFF OFF OFF<br />

Mo - Fr ON hrs:min 8:00 8:00 8:00 8:00 8:00 8:00<br />

Mo - Fr OFF hrs:min 18:00 22:00 22:00 22:00 22:00 22:00<br />

Sa - Su ON hrs:min 8:00 8:00 8:00 8:00 8:00 8:00<br />

Sa - Su OFF<br />

Manual operation<br />

hrs:min<br />

Dead man´s mode<br />

18:00 22:00 22:00 22:00 22:00 22:00<br />

Mode<br />

Time mode<br />

Permanent mode<br />

Continuous mode<br />

Permanent mode Permanent mode Time mode Permanent mode Permanent mode Time Mode<br />

Angle DOWN<br />

Display<br />

Degrees 0 0 38 0 0 38<br />

Contrast % 40<br />

Backlight dimmed % 50<br />

932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 35


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

Setting step Unit<br />

Product<br />

Product type -<br />

Fig. 7-2: Factory settings (Service settings)<br />

36<br />

Articulated<br />

arm<br />

awning<br />

Articulated<br />

arm<br />

awning<br />

We reserve the right to carry out improvements<br />

Conserv.-/<br />

Facadeawning<br />

Service settings<br />

Conservatory<br />

awning<br />

Outside<br />

venetian<br />

blind<br />

Outside<br />

venetian<br />

blind<br />

Roller<br />

shutter<br />

Pleated<br />

blind<br />

Roller shutter Pleated blind<br />

Inside<br />

venetian<br />

blind<br />

Inside<br />

venetian<br />

blind<br />

Runtime UP min:sec 1:00 2:00 2:30 2:30 1:20 2:30<br />

Runtime DOWN min:sec 1:00 2:00 2:30 2:30 1:20 2:30<br />

Turn time sec 0 0 1,6 0 0 1,2<br />

Slat angle max. Degrees 0 0 80 0 0 80<br />

Slat angle min. Degrees 0 0 -80 0 0 -80<br />

Control type<br />

Drive direct/<br />

with MCU<br />

Drive with<br />

MCU<br />

Drive with<br />

MCU<br />

Drive with<br />

MCU<br />

Drive with<br />

MCU<br />

Drive with<br />

MCU<br />

Drive with<br />

MCU<br />

Wind monitoring<br />

Wind monitoring ON/OFF ON ON ON OFF OFF OFF<br />

Limit UP m/s 8 10 12 --- --- ---<br />

Delay UP sec 1 1 5 0 0 0<br />

Delay OFF<br />

Ice monitoring<br />

min 10 10 10 0 0 0<br />

Ice monitoring ON/OFF OFF OFF OFF OFF OFF OFF<br />

Limit UP ° C 3 3 3 3 3 3<br />

Ice alert automatic reset<br />

System settings<br />

ON/OFF ON ON ON ON ON ON<br />

Integrated temperature<br />

sensor offset<br />

° C 2<br />

Duration wind sensor<br />

test<br />

hrs 99<br />

Software version - Dependent on the installed software<br />

Language<br />

Language Deutsch/English Deutsch<br />

932806B0•816758•7975k0•08.10.2004


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

8. Custom settings<br />

Setting step Unit Setting<br />

User settings<br />

Sun control<br />

Sun control<br />

ON/OFF<br />

ON/OFF<br />

Limit UP klx<br />

Delay UP min<br />

Limit OPEN klx<br />

Delay OPEN min<br />

Limit DOWN klx<br />

Delay DOWN min<br />

Position DOWN %<br />

Angle DOWN<br />

Dawn/dusk control<br />

Degrees<br />

Dawn/dusk control ON/OFF<br />

Limit UP lx<br />

Limit DOWN lx<br />

Angle DOWN<br />

Temperature control<br />

Degrees<br />

Temperature contropl ON/OFF<br />

Direct control<br />

Operating mode<br />

Enable sun<br />

Limit UP/OFF ° C<br />

Limit DOWN/ON<br />

Rain monitoring<br />

° C<br />

Rain monitoring<br />

Timer switch<br />

ON/OFF<br />

Timer switch ON/OFF<br />

Mo - Fr UP hrs:min<br />

Mo - Fr DOWN hrs:min<br />

Sa - Su UP hrs:min<br />

Sa - Su DOWN hrs:min<br />

Angle DOWN<br />

Comfort timer<br />

Degrees<br />

Comfort timer ON/OFF<br />

Mo - Fr ON hrs:min<br />

Mo - Fr OFF hrs:min<br />

Sa - Su ON hrs:min<br />

Sa - Su OFF<br />

Manual operating<br />

hrs:min<br />

Dead man´s mode<br />

Operating mode<br />

Time mode<br />

Permanent mode<br />

Continuous mode<br />

Angle DOWN<br />

Display<br />

Degrees<br />

Contrast %<br />

Backlight dimmed %<br />

Fig. 8-1: Custom settings (service settings)<br />

932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 37


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

38<br />

Setting step Unit Setting<br />

Product<br />

Product type<br />

Service settings<br />

Articulated arm<br />

awning<br />

Conservatory<br />

awning<br />

Outside venetian<br />

blind<br />

Roller shutter<br />

Pleated blind<br />

Inside venetian<br />

blind<br />

Runtime UP min:sec<br />

Runtime DOWN min:sec<br />

Turn time sec<br />

Slat angle max. Degrees<br />

Slat angle min. Degrees<br />

Control type<br />

Wind monitoring<br />

Drive direct/<br />

with MCU<br />

Wind monitoring ON/OFF<br />

Limit UP m/s<br />

Delay UP sec<br />

Delay OFF<br />

Ice monitoring<br />

min<br />

Ice monitoring ON/OFF<br />

Limit UP ° C<br />

Ice alert automatic reset<br />

System<br />

ON/OFF<br />

Integrated temperature<br />

sensor offset<br />

° C<br />

Duration wind sensor<br />

test<br />

hrs<br />

Software version -<br />

Language<br />

Language Deutsch/English<br />

Fig. 8-2: Eigene Einstellungen (Serviceinstellungen)<br />

We reserve the right to carry out improvements<br />

932806B0•816758•7975k0•08.10.2004


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

9. Technical data<br />

<strong>Wisotronic</strong> <strong>dialog</strong> 1-channel<br />

Supply<br />

min typ max unit<br />

Operating voltage 207 230 253 VAC<br />

Power consumption<br />

Outputs (Isolated)<br />

2,5 4 VA<br />

Switching capacity<br />

at 230 VAC / cos ϕ = 0,6<br />

700 VA<br />

Switching capacity at 24 VDC 72 W<br />

Microfuse<br />

Integrated "Temperature" sensor<br />

3,15 AT<br />

Measuring range<br />

HF-Receiver<br />

-25 +75 ° C<br />

Receive frequency ASK (OOK) 433,92 MHz<br />

Sensing range<br />

Ambient conditions<br />

30 m<br />

Operating temperature 0 +20 +40 ° C<br />

Storage temperature 0 +20 +50 ° C<br />

Humidity (non-condensing) 10 40 85 %RH<br />

Housing<br />

Degree of protection:<br />

In flush-type housing IP30<br />

In surface-type housing IP30<br />

Safety class II<br />

Field of application: Clean ambient conditions<br />

Connection<br />

Drive, Power supply Spring-load terminals<br />

Sensors Plugged/Screwed terminals<br />

Terminals<br />

Drive, Power supply 0,14...1,5 mm 2<br />

Sensors 0,14...1,5 mm 2<br />

Test Standards<br />

EN60730-1: 2002<br />

EN50081-1: 1992<br />

EN50082-1: 1997<br />

EN300220-3: 2000<br />

EN301489-3: 2001<br />

Other<br />

Automatic Type 1<br />

Method of operation<br />

Software class A<br />

Display Graphical LC-Display with background<br />

lighting<br />

Program control Clear text display / Icons<br />

Program input 4 button / dial with pushbutton<br />

Output isolated contact set<br />

Conformity<br />

932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 39


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

40<br />

We reserve the right to carry out improvements<br />

Fig. 9-1: Dimensions<br />

Article numbers<br />

<strong>Wisotronic</strong> <strong>dialog</strong> 1K UP EWFS 1002 556<br />

with 1-<strong>Channel</strong> remote control and<br />

„Wind/Photo“ sensor<br />

<strong>Wisotronic</strong> <strong>dialog</strong> 1K UP EWFS 1002 578<br />

with 1-<strong>Channel</strong> remote control<br />

Surface-type mounting set 1002 570<br />

TIP<br />

94<br />

170<br />

68<br />

65,5<br />

The device has been checked for observance of the statutory<br />

regulations on emitted interference in accordance with DIN<br />

EN 50081-1/1992 and on immunity to interference in<br />

accordance with DIN EN 50082-1/1992. The requirements are<br />

fulfilled or exceeded in connection with the specified supply<br />

cables and sensors of the manufacturer in all cases. DIN EN<br />

50081-1 and DIN EN 50082-1 apply for usage of the device in<br />

living areas, business and trade areas as well as in small<br />

companies. Additional measures may be required if used in<br />

industrial environments.<br />

932806B0•816758•7975k0•08.10.2004


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

10. User information<br />

For use in:<br />

A, B, D, DK, E, F, FIN, GB, GR, I, IRL, L, NL, P, S, CH, IS, N.<br />

Transmitter and reciever for sunblind remote control.<br />

The device complies at intended use with the essential requirements, which are<br />

fixed in the following EC-Guidelines and harmonized standards:<br />

- Directive on radio equipment and telecommunications terminal equipment and<br />

the mutual recognition of their conformity 1999/5/EC(R&TTE)<br />

- Directive on electromagnetic compability 89/336/EEC<br />

- Low voltage directive 73/23/EWG<br />

Link to declaration of confirmity:<br />

http://www.warema.de<br />

932806B0•816758•7975k0•08.10.2004 We reserve the right to carry out improvements 41


<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> Central<br />

Control Unit EWFS ®<br />

11. Notes<br />

42<br />

We reserve the right to carry out improvements<br />

932806B0•816758•7975k0•08.10.2004

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!