0.4° . The full dynamical theory can only be deduced for the specular reflectivity. For the diffuse<br />

scattering no exact solution exist right now .<br />

6.6 Important Applications of <strong>Neutron</strong> Reflectrometry<br />

For many standard scattering experiments on layer systems x-rays are much more suitable<br />

than neutrons because of the higher flux, the better collimation and the less divergence . In<br />

numbers : A standard synchrotron radiation source bas a primary beam intensity of about 10' °<br />

counts/sec at a typical spot size of (0.2x1)mm2 . The beam divergence which determines the Q-<br />

space resolution is less than 1/100 of a degree . For a modern neutron source one gets less than<br />

10 7 counts/sec in an area of (0.5x20)mm2 with a divergence of larger than 0 .02° .<br />

However, for some topics of research neutron scattering is superior . One example is the<br />

investigation of materials which mainly contain hydrogen, carbon, nitrogen or oxygen such as<br />

organic molecules . In this case the electron density [which for x-rays replaces the potentiel<br />

V(r)] is very low and the x-ray contrast becomes very small. In contrast, for neutron V(r)<br />

strongly depends on the isotope of the elements . Therefore, by using deuterated or<br />

hydrogenated organic materials the scattering contrast can easily be tuned without changing the<br />

chemical properties of the semples . Figure 6.11 shows an example of apolymer bilayer.<br />

h-PS<br />

12<br />

10<br />

ö<br />

s<br />

6<br />

rn<br />

4<br />

0<br />

50 100 150 200 250 300<br />

Figure 6 .11 : Comperison<br />

of an x-ray (left column)<br />

and a neutron (right<br />

column) reflectivity of a<br />

polymer bilayer (210Â<br />

polystyrene [PSI on 70Â<br />

deuterated polyvinylpyrridine<br />

[d-P2VP] on a sifcon<br />

z ra1 substrate) . The x-ray<br />

contrast between the two<br />

polymes given by the<br />

electron density lis only<br />

about 5% .<br />

0.10 0,15 020 0 .25 A 30 2 0 .00 0.05 010 015 0.20 0 .25 0.30<br />

0. rß - ' 1 0= rx- ' 1<br />

It can clearly be seen that the x-ray reflectivity only exhibits one signiflcant oscillation<br />

period which is due to the whole fihm thickness . The x-ray contrast at the polymer interface is<br />

6 . 15