<strong>POLYURETHANE</strong> MEMBRANE DESMOPOL<br />
Singular points<br />
Sometimes it is necessary to carry out preparatory and conditioning work prior to application of DESMOPOL<br />
system, because it depends largely on the waterproofing membrane is fully effective and sustainable. We detail<br />
the most common elements that can be found, if some use is not described; please contact TECNOPOL<br />
Technical Service.<br />
8<br />
Encounter with downspouts<br />
In reparation jobs, once the tank is ready, proceed to<br />
apply DESMOPOL system across the internal<br />
circumference of the downspout, so up and down<br />
exceeding 10 cm, sometimes more distance,<br />
depending of the maximum level of water expected<br />
(exp: case of extreme precipitation).<br />
Expansion joints<br />
Fill the joints with polyurethane mastic, and then<br />
apply a waterproofing band reinforced by a geotextile<br />
mesh as TECNOBAND. This should cover<br />
between 10 at 15 cm on each joint side.<br />
Cracks<br />
There are passive or active cracks (more than 3 mm<br />
wide), After opening with a sanding disc or other<br />
similar tool than cleaning must fill them with a mastic<br />
or sealant as DESMOSEAL MASTIC PU, after its<br />
drying, we apply the DESMOPOL polyurethane<br />
membrane, it is important to test compatibility of<br />
both elements.<br />
Edges,ridges and encounters<br />
Sharp edges, sides and encounters must be<br />
rounded than treated with mastic as DESMOSEAL<br />
MASILLA PU, if necessary adding a geo-textile<br />
mesh layer as reinforcement.<br />
Vertical perimeters<br />
It is also necessary to perform the conditioning of<br />
vertical perimeters before applying the<br />
waterproofing membrane DESMOPOL.<br />
Wiring / Sockets<br />
Cables and sockets are treated as singular<br />
elements, and they must be treated before the<br />
waterproofing membrane is installed.