■ Technical specifications (continued)<br />
6ES7 352-<br />
5AH00-0AE0<br />
6ES7 352-<br />
5AH10-0AE0<br />
Sensor (continued)<br />
Incremental encoder<br />
(asymmetrical)<br />
- Track mark signals A, B A, B<br />
- Zero mark signal N N<br />
- Input voltage 24 V 24 V<br />
- Input frequency, max. 200 kHz 200 kHz<br />
- Length of cable (shielded), max. 50 m; Cable<br />
length, HTL<br />
incremental<br />
encoder, Siemens,<br />
Type<br />
6FX2001-4:<br />
50kHz, 25 m<br />
shielded, max.,<br />
25kHz, 50 m<br />
shielded, max.<br />
Absolute encoder (SSI)<br />
50 m; Cable<br />
length, HTL<br />
incremental<br />
encoder, Siemens,<br />
Type<br />
6FX2001-4:<br />
50kHz, 25 m<br />
shielded, max.,<br />
25kHz, 50 m<br />
shielded, max.<br />
- Data signal DATA, notDATA DATA, notDATA<br />
- Clock signal CK, notCK CK, notCK<br />
- Frame length 13 or 25 bits 13 or 25 bits<br />
- Clock frequency, max. 1 MHz;<br />
125 kHz,<br />
250 kHz,<br />
500 kHz, or<br />
1MHz<br />
1 MHz;<br />
125 kHz,<br />
250 kHz,<br />
500 kHz, or<br />
1MHz<br />
- Length of cable (shielded), max. 320 m; Cable<br />
length, RS-422<br />
SSI absolute<br />
encoder Siemens<br />
Type<br />
6FX201-5, 24V<br />
supply:<br />
125kHz, 320<br />
meters<br />
shielded, max.,<br />
250kHz, 160<br />
meters<br />
shielded, max.,<br />
500kHz, 60<br />
meters<br />
shielded, max.,<br />
1MHz, 20<br />
meters<br />
shielded, max.<br />
- Monoflop time adjustable:<br />
16/32/48/64 µs<br />
- Listening mode Yes; up to two<br />
stations<br />
- Multi-turn Yes; 25 bit<br />
frame<br />
Sensor signal evaluation<br />
- Count direction, up Yes Yes<br />
- Count direction, down Yes Yes<br />
Response times<br />
• Input response time to output<br />
response time<br />
5V input to 24V<br />
output, 0 filter:<br />
1 to 4µs (typ);<br />
24V input to<br />
24V output, 0<br />
filter: 2 to 6µs<br />
(type)<br />
320 m; Cable<br />
length, RS-422<br />
SSI absolute<br />
encoder Siemens<br />
Type<br />
6FX201-5, 24V<br />
supply:<br />
125kHz, 320<br />
meters<br />
shielded, max.,<br />
250kHz, 160<br />
meters<br />
shielded, max.,<br />
500kHz, 60<br />
meters<br />
shielded, max.,<br />
1MHz, 20<br />
meters<br />
shielded, max.<br />
adjustable:<br />
16/32/48/64 µs<br />
Yes; up to two<br />
stations<br />
Yes; 25 bit<br />
frame<br />
5V input to 24V<br />
output, 0 filter:<br />
1 to 4µs (typ);<br />
24V input to<br />
24V output, 0<br />
filter: 2 to 6µs<br />
(type)<br />
SIMATIC S7-<strong>300</strong><br />
Function modules<br />
FM 352-5 High-Speed Boolean Processor<br />
Counter<br />
• Counting range, description<br />
6ES7 352-<br />
5AH00-0AE0<br />
Counting range<br />
(16-bit<br />
counter): -<br />
32768 to 32767<br />
(user-specific<br />
within this<br />
range); counting<br />
range (32-<br />
bit counter): -<br />
2,147,483,<br />
648 to<br />
2,147,483,647<br />
(user-specific<br />
within this<br />
range)<br />
6ES7 352-<br />
5AH10-0AE0<br />
Counting range<br />
(16-bit<br />
counter): -<br />
32768 to 32767<br />
(user-specific<br />
within this<br />
range); counting<br />
range (32-<br />
bit counter): -<br />
2,147,483,<br />
648 to<br />
2,147,483,647<br />
(user-specific<br />
within this<br />
range)<br />
• Counting range, lower limit -2,147,483,648 -2,147,483,648<br />
• Counting range, upper limit 2,147,483,647 2,147,483,647<br />
Count mode<br />
-Single Yes Yes<br />
- Continuous Yes Yes<br />
- Periodic Yes Yes<br />
Status information/ interrupts/<br />
diagnostics<br />
Interrupts<br />
- Diagnostic interrupt Yes; 1L, 2L, 3L<br />
missing; MMC<br />
error; output<br />
overload (8);<br />
overloaded<br />
encoder<br />
supply; differential<br />
broken<br />
wire; parameterization<br />
error;<br />
SSI frame overrun<br />
- Process interrupt Yes; 8 available;<br />
to be<br />
generated by<br />
the user<br />
program<br />
Diagnostics<br />
- Wire break in sensor cable Yes Yes<br />
- Overflow/underflow Yes Yes<br />
- No load voltage Yes Yes<br />
Potentials/ electrical isolation<br />
• between 1L and 2L and 3L Yes; 75 V DC /<br />
60 V AC<br />
• between the digital I/O & 2L and<br />
sensor I/O & 3L<br />
• between the backplane bus and<br />
the digital & sensor I/O & 1L & 2L<br />
& 3L<br />
Digital input functions<br />
- Electrical isolation,<br />
digital input functions<br />
Yes (75 V DC,<br />
60 V AC)<br />
Yes (75 V DC,<br />
60 V AC)<br />
Yes; Yes CPU,<br />
I/O and<br />
encoder units<br />
are separate<br />
Yes; 1L, 2L, 3L<br />
missing; MMC<br />
error; output<br />
overload (8);<br />
overloaded<br />
encoder<br />
supply; differential<br />
broken<br />
wire; parameterization<br />
error;<br />
SSI frame overrun<br />
Yes; 8 available;<br />
to be<br />
generated by<br />
the user<br />
program<br />
Yes; 75 V DC /<br />
60 V AC<br />
Yes (75 V DC,<br />
60 V AC)<br />
Yes (75 V DC,<br />
60 V AC)<br />
Yes; Yes CPU,<br />
I/O and<br />
encoder units<br />
are separate<br />
4<br />
Siemens ST 70 · 2005<br />