■ Technical specifications (continued)<br />

6ES7 352-<br />

5AH00-0AE0<br />

6ES7 352-<br />

5AH10-0AE0<br />

Sensor (continued)<br />

Incremental encoder<br />

(asymmetrical)<br />

- Track mark signals A, B A, B<br />

- Zero mark signal N N<br />

- Input voltage 24 V 24 V<br />

- Input frequency, max. 200 kHz 200 kHz<br />

- Length of cable (shielded), max. 50 m; Cable<br />

length, HTL<br />

incremental<br />

encoder, Siemens,<br />

Type<br />

6FX2001-4:<br />

50kHz, 25 m<br />

shielded, max.,<br />

25kHz, 50 m<br />

shielded, max.<br />

Absolute encoder (SSI)<br />

50 m; Cable<br />

length, HTL<br />

incremental<br />

encoder, Siemens,<br />

Type<br />

6FX2001-4:<br />

50kHz, 25 m<br />

shielded, max.,<br />

25kHz, 50 m<br />

shielded, max.<br />

- Data signal DATA, notDATA DATA, notDATA<br />

- Clock signal CK, notCK CK, notCK<br />

- Frame length 13 or 25 bits 13 or 25 bits<br />

- Clock frequency, max. 1 MHz;<br />

125 kHz,<br />

250 kHz,<br />

500 kHz, or<br />

1MHz<br />

1 MHz;<br />

125 kHz,<br />

250 kHz,<br />

500 kHz, or<br />

1MHz<br />

- Length of cable (shielded), max. 320 m; Cable<br />

length, RS-422<br />

SSI absolute<br />

encoder Siemens<br />

Type<br />

6FX201-5, 24V<br />

supply:<br />

125kHz, 320<br />

meters<br />

shielded, max.,<br />

250kHz, 160<br />

meters<br />

shielded, max.,<br />

500kHz, 60<br />

meters<br />

shielded, max.,<br />

1MHz, 20<br />

meters<br />

shielded, max.<br />

- Monoflop time adjustable:<br />

16/32/48/64 µs<br />

- Listening mode Yes; up to two<br />

stations<br />

- Multi-turn Yes; 25 bit<br />

frame<br />

Sensor signal evaluation<br />

- Count direction, up Yes Yes<br />

- Count direction, down Yes Yes<br />

Response times<br />

• Input response time to output<br />

response time<br />

5V input to 24V<br />

output, 0 filter:<br />

1 to 4µs (typ);<br />

24V input to<br />

24V output, 0<br />

filter: 2 to 6µs<br />

(type)<br />

320 m; Cable<br />

length, RS-422<br />

SSI absolute<br />

encoder Siemens<br />

Type<br />

6FX201-5, 24V<br />

supply:<br />

125kHz, 320<br />

meters<br />

shielded, max.,<br />

250kHz, 160<br />

meters<br />

shielded, max.,<br />

500kHz, 60<br />

meters<br />

shielded, max.,<br />

1MHz, 20<br />

meters<br />

shielded, max.<br />

adjustable:<br />

16/32/48/64 µs<br />

Yes; up to two<br />

stations<br />

Yes; 25 bit<br />

frame<br />

5V input to 24V<br />

output, 0 filter:<br />

1 to 4µs (typ);<br />

24V input to<br />

24V output, 0<br />

filter: 2 to 6µs<br />

(type)<br />

SIMATIC S7-<strong>300</strong><br />

Function modules<br />

FM 352-5 High-Speed Boolean Processor<br />

Counter<br />

• Counting range, description<br />

6ES7 352-<br />

5AH00-0AE0<br />

Counting range<br />

(16-bit<br />

counter): -<br />

32768 to 32767<br />

(user-specific<br />

within this<br />

range); counting<br />

range (32-<br />

bit counter): -<br />

2,147,483,<br />

648 to<br />

2,147,483,647<br />

(user-specific<br />

within this<br />

range)<br />

6ES7 352-<br />

5AH10-0AE0<br />

Counting range<br />

(16-bit<br />

counter): -<br />

32768 to 32767<br />

(user-specific<br />

within this<br />

range); counting<br />

range (32-<br />

bit counter): -<br />

2,147,483,<br />

648 to<br />

2,147,483,647<br />

(user-specific<br />

within this<br />

range)<br />

• Counting range, lower limit -2,147,483,648 -2,147,483,648<br />

• Counting range, upper limit 2,147,483,647 2,147,483,647<br />

Count mode<br />

-Single Yes Yes<br />

- Continuous Yes Yes<br />

- Periodic Yes Yes<br />

Status information/ interrupts/<br />

diagnostics<br />

Interrupts<br />

- Diagnostic interrupt Yes; 1L, 2L, 3L<br />

missing; MMC<br />

error; output<br />

overload (8);<br />

overloaded<br />

encoder<br />

supply; differential<br />

broken<br />

wire; parameterization<br />

error;<br />

SSI frame overrun<br />

- Process interrupt Yes; 8 available;<br />

to be<br />

generated by<br />

the user<br />

program<br />

Diagnostics<br />

- Wire break in sensor cable Yes Yes<br />

- Overflow/underflow Yes Yes<br />

- No load voltage Yes Yes<br />

Potentials/ electrical isolation<br />

• between 1L and 2L and 3L Yes; 75 V DC /<br />

60 V AC<br />

• between the digital I/O & 2L and<br />

sensor I/O & 3L<br />

• between the backplane bus and<br />

the digital & sensor I/O & 1L & 2L<br />

& 3L<br />

Digital input functions<br />

- Electrical isolation,<br />

digital input functions<br />

Yes (75 V DC,<br />

60 V AC)<br />

Yes (75 V DC,<br />

60 V AC)<br />

Yes; Yes CPU,<br />

I/O and<br />

encoder units<br />

are separate<br />

Yes; 1L, 2L, 3L<br />

missing; MMC<br />

error; output<br />

overload (8);<br />

overloaded<br />

encoder<br />

supply; differential<br />

broken<br />

wire; parameterization<br />

error;<br />

SSI frame overrun<br />

Yes; 8 available;<br />

to be<br />

generated by<br />

the user<br />

program<br />

Yes; 75 V DC /<br />

60 V AC<br />

Yes (75 V DC,<br />

60 V AC)<br />

Yes (75 V DC,<br />

60 V AC)<br />

Yes; Yes CPU,<br />

I/O and<br />

encoder units<br />

are separate<br />

4<br />

Siemens ST 70 · 2005<br />