simatic s7-300 - megaelektrik.net
simatic s7-300 - megaelektrik.net
simatic s7-300 - megaelektrik.net
- No tags were found...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
4<br />
SIMATIC S7-<strong>300</strong><br />
Function modules<br />
FM 352-5 High-Speed Boolean Processor<br />
■ Technical specifications (continued)<br />
6ES7 352-<br />
5AH00-0AE0<br />
6ES7 352-<br />
5AH10-0AE0<br />
Digital outputs<br />
• Number of digital outputs 8 8<br />
• M-switching<br />
Yes<br />
• P-switching<br />
Yes<br />
• Length of cable shielded, max. 600 m 600 m<br />
• Length of cable unshielded, max. 100 m 100 m<br />
• Short-circuit protection of the output<br />
• Short-circuit protection of the output,<br />
response threshold, typical<br />
• Limitation of voltage induced on<br />
circuit interruption to<br />
Yes; Overvoltage<br />
protection,<br />
thermal protection<br />
Yes; Overvoltage<br />
protection,<br />
thermal protection<br />
1.7 A to 3.5 A 1.7 A to 3.5 A<br />
2M +45 V typ,<br />
(40 ..55 V)<br />
Note: no protection<br />
against<br />
inductive kickback<br />
>55mJ<br />
2M +45 V typ,<br />
(40 ..55 V)<br />
Note: no protection<br />
against<br />
inductive kickback<br />
>55mJ<br />
• Lamp load, max. 5 W 5 W<br />
• Driving a digital input No No<br />
Output voltage<br />
- Rated value (DC) 24 V 24 V<br />
- for 0 signal (DC), max. 28.8 V 28.8 V<br />
- for 1 signal (DC), max. 0.5 V 0.5 V<br />
Output current<br />
- for 1 signal rated value 0.5 A; at 60 °C 0.5 A; at 60 °C<br />
- for 1 signal permissible range<br />
for 0 to 60 °C, min.<br />
5 mA 5 mA<br />
- for 1 signal permissible range<br />
for 0 to 60 °C, max.<br />
600 mA 600 mA<br />
- for 0 signal residual current, max. 1 mA 1 mA<br />
Output delay at resistive load<br />
- "0" to "1", max. 1 µs;<br />
0.6 µs 50 mA /<br />
1.0 µs 0.5 Amp<br />
- "1" to "0", max. 1.5 µs;<br />
1.7µs 50 mA /<br />
1.5µs 0.5 Amp<br />
Parallel switching of 2 outputs<br />
- to increase power Yes; 2 Yes; 2<br />
Switching frequency<br />
- at resistive load, max. 100 kHz;<br />
20 kHz at 0.5<br />
amps;<br />
100 kHz at 0.25<br />
amp<br />
- at inductive load, max. 2 Hz; 2 Hz at<br />
0.5 amps with<br />
external commutator<br />
diodes;<br />
0.5Hz at 0.5<br />
amps without<br />
external commutator<br />
diodes<br />
- at lamp load, max. 10 Hz 10 Hz<br />
1 µs;<br />
0.6 µs 50 mA /<br />
1.0 µs 0.5 Amp<br />
1.5 µs;<br />
1.7µs 50 mA /<br />
1.5µs 0.5 Amp<br />
100 kHz;<br />
20 kHz at 0.5<br />
amps;<br />
100 kHz at 0.25<br />
amp<br />
2 Hz; 2 Hz at<br />
0.5 amps with<br />
external commutator<br />
diodes;<br />
0.5Hz at 0.5<br />
amps without<br />
external commutator<br />
diodes<br />
6ES7 352-<br />
5AH00-0AE0<br />
Sensor supply<br />
5 V - sensor supply<br />
-5 V Yes Yes<br />
- Short-circuit protection Yes; Electronic<br />
overload protection.<br />
Not<br />
protected when<br />
normal or<br />
counter voltage<br />
applied.<br />
6ES7 352-<br />
5AH10-0AE0<br />
Yes; Electronic<br />
overload protection.<br />
Not<br />
protected when<br />
normal or<br />
counter voltage<br />
applied.<br />
- Output current, max. 250 mA 250 mA<br />
24 V - sensor supply<br />
- 24 V Yes Yes<br />
- Short-circuit protection Yes; Overcurrent<br />
and overheating<br />
protection pn<br />
overload. Diagnostics,<br />
if output<br />
temperature<br />
limit reached.<br />
Not protected<br />
when normal or<br />
counter voltage<br />
applied<br />
Yes; Overcurrent<br />
and overheating<br />
protection pn<br />
overload. Diagnostics,<br />
if output<br />
temperature<br />
limit reached.<br />
Not protected<br />
when normal or<br />
counter voltage<br />
applied<br />
- Output current, max. 400 mA 400 mA<br />
Sensor<br />
Connectable encoders<br />
- Incremental encoder<br />
(symmetrical)<br />
Yes<br />
Yes<br />
- Incremental encoder<br />
(asymmetrical)<br />
Yes<br />
Yes<br />
- Absolute encoder (SSI) Yes Yes<br />
- permissible closed-circuit current<br />
(2-wire BEROS), max.<br />
Yes; typ. 1 A Yes; typ. 1 A<br />
Incremental encoder (symmetrical) 1.5 mA 1.5 mA<br />
- Track mark signals<br />
- Zero mark signal A, notA, B, notB A, notA, B, notB<br />
- Input signal N, notN N, notN<br />
- Input frequency, max. 5 V-Differenzsignal<br />
(phys. RS 422)<br />
- Length of cable (shielded), max. 1 MHz 1 MHz<br />
- permissible closed-circuit<br />
current (2-wire BEROS), max.<br />
100 m; Cable<br />
length, RS-422<br />
(5V) incremental<br />
encoder,<br />
Siemens Type<br />
6FX201-2, 5V<br />
supply:<br />
500kHz, 32<br />
meters,<br />
shielded, max.;<br />
cable length,<br />
RS-422 (5V)<br />
incremental<br />
encoder, Siemens<br />
Type<br />
6FX201-2, 24V<br />
supply: 500<br />
kHz, 100<br />
meters,<br />
shielded, max.<br />
5 V-Differenzsignal<br />
(phys. RS 422)<br />
100 m; Cable<br />
length, RS-422<br />
(5V) incremental<br />
encoder,<br />
Siemens Type<br />
6FX201-2, 5V<br />
supply:<br />
500kHz, 32<br />
meters,<br />
shielded, max.;<br />
cable length,<br />
RS-422 (5V)<br />
incremental<br />
encoder, Siemens<br />
Type<br />
6FX201-2, 24V<br />
supply: 500<br />
kHz, 100<br />
meters,<br />
shielded, max.<br />
4/102 Siemens ST 70 · 2005