simatic s7-300 - megaelektrik.net
simatic s7-300 - megaelektrik.net
simatic s7-300 - megaelektrik.net
- No tags were found...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
SIMATIC S7-<strong>300</strong><br />
Function modules<br />
FM 352-5 High-Speed Boolean Processor<br />
■ Overview<br />
• The FM 352-5 High-speed Bo olean processor offers an<br />
extremely fast binary control and some of the quickest<br />
switching procedures ever possible (cycle duration: 1 µs)<br />
• Programming with LAD or FBD is possible<br />
• The instruction set availabl e includes bit instructions<br />
(instruction subset of STEP 7), timers, counters, frequency<br />
dividers, frequency generators, and shift registers<br />
• 12 integrated DI/8 integrated DO<br />
• 2 versions: Current sinking or current sourcing digital outputs<br />
• 1 channel for connecting a 24 V incremental encoder,<br />
a 5 V incremental encoder (RS422) or a serial interface<br />
absolute encoder<br />
4<br />
A micro memory card is required for operation of the FM 352-5.<br />
Note:<br />
SIMODRIVE Sensor/Motion Connect 500 feature positionmeasuring<br />
systems and preassembled connecting cables for<br />
counting and positioning functions.<br />
Additional information is available in the Inter<strong>net</strong> under:<br />
http://www.siemens.com/<strong>simatic</strong>-technology<br />
■ Technical specifications<br />
6ES7 352-<br />
5AH00-0AE0<br />
6ES7 352-<br />
5AH10-0AE0<br />
Supply voltages<br />
Rated value<br />
- 24 V DC Yes Yes<br />
Voltages and currents<br />
Load voltage L+<br />
- Rated value (DC) 24 V 24 V<br />
- Reverse polarity protection Yes Yes<br />
- permissible range, lower limit 20.4 V 20.4 V<br />
(DC)<br />
- permissible range, upper limit<br />
(DC)<br />
28.8 V 28.8 V<br />
Current consumption<br />
• from load voltage 1L+, max<br />
• from load voltage 2L+<br />
(no load), max.<br />
• from load voltage 3L+<br />
(with sensor), max.<br />
• from load voltage 3L+<br />
(no sensor), max.<br />
150 mA;<br />
typ. 60 mA<br />
200 mA;<br />
typ. 60 mA,<br />
DE/DA supply<br />
600 mA;<br />
typ. 80 mA plus<br />
encoder power<br />
supply<br />
200 mA;<br />
typ. 80 mA<br />
150 mA;<br />
typ. 60 mA<br />
200 mA;<br />
typ. 60 mA,<br />
DE/DA supply<br />
600 mA;<br />
typ. 80 mA plus<br />
encoder power<br />
supply<br />
200 mA;<br />
typ. 80 mA<br />
• from backplane bus 5 V DC, max. 100 mA; typ. 100 mA; typ.<br />
• Power dissipation, typical 6,5 W 6.5 W<br />
Memory/backup<br />
Memory<br />
- Memory card, RAM 128 KByte;<br />
required for<br />
operation,<br />
MMC<br />
Interfaces<br />
• Update time<br />
PLC interface:<br />
5ms<br />
(2.6 ms typ.)<br />
128 kByte;<br />
required for<br />
operation,<br />
MMC<br />
PLC interface:<br />
5ms<br />
(2.6 ms typ.)<br />
Connection system<br />
• Requisite front connector 1 x 40-pin 1 x 40-pin<br />
6ES7 352-<br />
5AH00-0AE0<br />
CPU/ programming<br />
• Program cycle time (scan) 1 µs 1 µs<br />
Digital inputs<br />
6ES7 352-<br />
5AH10-0AE0<br />
• Number of digital inputs<br />
8; as standard<br />
and up to 12 at<br />
24 V DC<br />
encoder inputs<br />
as digital<br />
inputs<br />
Length of cable<br />
- Length of cable shielded, max 600 m;<br />
shielded cable<br />
advisable when<br />
filtering set at<br />
1.6 ms raster.<br />
- Length of cable unshielded, max. 100 m 100 m<br />
8; as standard<br />
and up to 12 at<br />
24 V DC<br />
encoder inputs<br />
as digital<br />
inputs<br />
600 m;<br />
shielded cable<br />
advisable when<br />
filtering set at<br />
1.6 ms raster.<br />
Input voltage<br />
- Rated value, DC 24 V 24 V<br />
- for signal "0" -30 V to 5 V -30 V to 5 V<br />
- for signal "1" 11 to 30 V 11 to 30 V<br />
Input current<br />
- for 0 signal, max (permissible 1.5 mA 1.5 mA<br />
closed-circuit current)<br />
- for 1 signal, typical 3.8 mA 3.8 mA<br />
Input delay (at rated value of the<br />
input voltage)<br />
- Input frequency<br />
(at 0.1ms delay time), max.<br />
200 kHz 200 kHz<br />
- Programmable digital filter delay none, 5µs,<br />
10µs, 15µs,<br />
20µs, 50µs,<br />
1,5ms<br />
- Minimum pulse width for<br />
program reaction<br />
1µs, 5µs, 10µs,<br />
15µs, 20µs,<br />
50µs, 1,6ms<br />
none, 5µs,<br />
10µs, 15µs,<br />
20µs, 50µs,<br />
1,5ms<br />
1µs, 5µs, 10µs,<br />
15µs, 20µs,<br />
50µs, 1,6ms<br />
• For standard inputs<br />
- at 0 to 1, max. 3 µs; typ. 1,5 µs 3 µs; typ. 1,5 µs<br />
Siemens ST 70 · 2005<br />
4/101