SIMATIC S7-300 Central processing units CPU 312C to CPU 317F-2 DP ■ Technical specifications (continued) 6ES7 312- 5BD01-0AB0 6ES7 313- 5BE01-0AB0 6ES7 313- 6BE01-0AB0 6ES7 313- 6CE01-0AB0 6ES7 314- 6BF01-0AB0 6ES7 314- 6CF01-0AB0 CPU/ programming Programming language - STEP 7 Yes; V5.1 SP2 Yes; V5.1 SP2 Yes; V5.1 SP2 Yes; V5.1 SP2 Yes; V5.1 SP2 Yes; V5.1 SP2 -LAD Yes Yes Yes Yes Yes Yes -FBD Yes Yes Yes Yes Yes Yes -STL Yes Yes Yes Yes Yes Yes -SCL Yes Yes Yes Yes Yes Yes -CFC Yes Yes - GRAPH Yes Yes Yes Yes Yes Yes - HiGraph ® Yes Yes Yes Yes Yes Yes Software library • Instruction set See instruction list See instruction list See instruction list See instruction list See instruction list See instruction list • Bracket levels 8 8 8 8 8 8 • User program protection/ Yes Yes Yes Yes Yes Yes password protection • System functions (SFC) See instruction list See instruction list See instruction list See instruction list See instruction list See instruction list • System function blocks (SFB) See instruction list See instruction list See instruction list See instruction list See instruction list Digital inputs • Number of digital inputs 10 24 16 16 24 24 Length of cable - Length of cable shielded, max. 1,000 m; 100 m for technological functions 1,000 m; 100 m for technological functions 1,000 m; 100 m for technological functions 1,000 m; 100 m for technological functions 1,000 m; 100 m for technological functions See instruction list 1,000 m; 100 m for technologial functions - Length of cable unshielded, max. 600 m 600 m 600 m 600 m 600 m 600 m Input voltage - Rated value, DC 24 V 24 V 24 V 24 V 24 V 24 V - for signal "0" -3 to 5 V -3 to 5 V -3 to 5 V -3 to 5 V -3 to 5 V -3 to 5 V - for signal "1" 15 to 30 V 15 to 30 V 15 to 30 V 15 to 30 V 15 to 30 V 15 to 30 V Input current - for 1 signal, typical 8 mA 8 mA 8 mA 8 mA 8 mA 8 mA Input delay (at rated value of the input voltage) • For standard inputs - Parameterizable Yes; 0,1 / 0,3 / 3 / 15 ms Yes; 0,1 / 0,3 / 3 / 15 ms Yes; 0,1 / 0,3 / 3 / 15 ms Yes; 0,1 / 0,3 / 3 / 15 ms Yes; 0,1 / 0,3 / 3 / 15 ms • for counters/technological functions - at 0 to 1, max. 50 µs 16 µs 8 µs 8 µs 8 µs 8 µs Yes; 0,1 / 0,3 / 3 / 15 ms 4 Siemens ST 70 · 2005 4/15

SIMATIC S7-300 Central processing units CPU 312C to CPU 317F-2 DP 4 ■ Technical specifications (continued) 6ES7 312- 5BD01-0AB0 6ES7 313- 5BE01-0AB0 6ES7 313- 6BE01-0AB0 6ES7 313- 6CE01-0AB0 6ES7 314- 6BF01-0AB0 6ES7 314- 6CF01-0AB0 Digital outputs • Number of digital outputs 6 16 16 16 16 16 • Length of cable shielded, max. 1,000 m 1,000 m 1,000 m 1,000 m 1,000 m 1,000 m • Length of cable unshielded, max. 600 m 600 m 600 m 600 m 600 m 600 m • Short-circuit protection of the output • Limitation of voltage induced on circuit interruption to Yes; clocking electronically Yes; clocking electronically Yes; clocking electronically Yes; clocking electronically Yes; clocking electronically Yes; clocking electronically L+ (-48 V) L+ (-48 V) L+ (-48 V) L+ (-48 V) L+ (-48 V) L+ (-48 V) Output voltage - for 1 signal L+ (-0.8 V) L+ (-0.8 V) L+ (-0.8 V) L+ (-0.8 V) L+ (-0.8 V) L+ (-0.8 V) Output current - for 1 signal permissible range for 0 to 40 °C, max. 500 mA 500 mA 500 mA 500 mA 500 mA 500 mA - for 1 signal permissible range for 0 to 60 °C, max. 500 mA 500 mA 500 mA 500 mA 500 mA 500 mA - for 1 signal minimum load 5 mA 5 mA 5 mA 5 mA 5 mA 5 mA current - for 0 signal residual current, max. 0.5 mA 0.5 mA 0.5 mA 0.5 mA 0.5 mA 0.5 mA Switching frequency - at resistive load, max. 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz - at inductive load, max. 0.5 Hz 0.5 Hz 0.5 Hz 0.5 Hz 0.5 Hz 0.5 Hz Summation current of the outputs (per group) • horizontal mounting positions - up to 40 °C, max. 3 A 8 A 8 A 8 A 8 A 8 A - up to 60 °C, max. 1.5 A 4 A 4 A 4 A 4 A 4 A Analog inputs • Number of analog inputs for voltage/current 4 4 4 measurement • Number of analog inputs for resistance/temperature 1 1 1 measurement) • Technical unit for temperature Yes Yes Yes measurement, adjustable Input ranges (rated values), voltages - 0 to +10 V Yes Yes Yes - -10 V to +10 V Yes Yes Yes Input ranges (rated values), currents - 0 to 20 mA Yes Yes Yes - -20 to +20 mA Yes Yes Yes - 4 to 20 mA Yes Yes Yes Input ranges (rated values), resistances - 0 to 600 ohms Yes Yes Yes Input ranges (rated values), resistance thermometer - Pt 100 Yes Yes Yes 4/16 Siemens ST 70 · 2005

SIMATIC S7-<strong>300</strong><br />

Central processing units<br />

CPU 312C to CPU 317F-2 DP<br />

4<br />

■ Technical specifications (continued)<br />

6ES7 312-<br />

5BD01-0AB0<br />

6ES7 313-<br />

5BE01-0AB0<br />

6ES7 313-<br />

6BE01-0AB0<br />

6ES7 313-<br />

6CE01-0AB0<br />

6ES7 314-<br />

6BF01-0AB0<br />

6ES7 314-<br />

6CF01-0AB0<br />

Digital outputs<br />

• Number of digital outputs 6 16 16 16 16 16<br />

• Length of cable shielded, max. 1,000 m 1,000 m 1,000 m 1,000 m 1,000 m 1,000 m<br />

• Length of cable unshielded, max. 600 m 600 m 600 m 600 m 600 m 600 m<br />

• Short-circuit protection of the<br />

output<br />

• Limitation of voltage induced on<br />

circuit interruption to<br />

Yes; clocking<br />

electronically<br />

Yes; clocking<br />

electronically<br />

Yes; clocking<br />

electronically<br />

Yes; clocking<br />

electronically<br />

Yes; clocking<br />

electronically<br />

Yes; clocking<br />

electronically<br />

L+ (-48 V) L+ (-48 V) L+ (-48 V) L+ (-48 V) L+ (-48 V) L+ (-48 V)<br />

Output voltage<br />

- for 1 signal L+ (-0.8 V) L+ (-0.8 V) L+ (-0.8 V) L+ (-0.8 V) L+ (-0.8 V) L+ (-0.8 V)<br />

Output current<br />

- for 1 signal permissible range<br />

for 0 to 40 °C, max.<br />

500 mA 500 mA 500 mA 500 mA 500 mA 500 mA<br />

- for 1 signal permissible range<br />

for 0 to 60 °C, max.<br />

500 mA 500 mA 500 mA 500 mA 500 mA 500 mA<br />

- for 1 signal minimum load 5 mA 5 mA 5 mA 5 mA 5 mA 5 mA<br />

current<br />

- for 0 signal residual current, max. 0.5 mA 0.5 mA 0.5 mA 0.5 mA 0.5 mA 0.5 mA<br />

Switching frequency<br />

- at resistive load, max. 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz<br />

- at inductive load, max. 0.5 Hz 0.5 Hz 0.5 Hz 0.5 Hz 0.5 Hz 0.5 Hz<br />

Summation current of the outputs<br />

(per group)<br />

• horizontal mounting positions<br />

- up to 40 °C, max. 3 A 8 A 8 A 8 A 8 A 8 A<br />

- up to 60 °C, max. 1.5 A 4 A 4 A 4 A 4 A 4 A<br />

Analog inputs<br />

• Number of analog inputs for voltage/current<br />

4 4 4<br />

measurement<br />

• Number of analog inputs for resistance/temperature<br />

1 1 1<br />

measurement)<br />

• Technical unit for temperature<br />

Yes Yes Yes<br />

measurement, adjustable<br />

Input ranges (rated values),<br />

voltages<br />

- 0 to +10 V Yes Yes Yes<br />

- -10 V to +10 V Yes Yes Yes<br />

Input ranges (rated values),<br />

currents<br />

- 0 to 20 mA Yes Yes Yes<br />

- -20 to +20 mA Yes Yes Yes<br />

- 4 to 20 mA Yes Yes Yes<br />

Input ranges (rated values),<br />

resistances<br />

- 0 to 600 ohms Yes Yes Yes<br />

Input ranges (rated values),<br />

resistance thermometer<br />

- Pt 100 Yes Yes Yes<br />

4/16 Siemens ST 70 · 2005