SIMATIC S7-300 Central processing units CPU 312C to CPU 317F-2 DP ■ Technical specifications (continued) 6ES7 312- 5BD01-0AB0 6ES7 313- 5BE01-0AB0 6ES7 313- 6BE01-0AB0 6ES7 313- 6CE01-0AB0 6ES7 314- 6BF01-0AB0 6ES7 314- 6CF01-0AB0 1st interface Functionality -MPI Yes Yes Yes Yes Yes Yes -DP master No No No No No No - DP slave No No No No No No - Point-to-point connection No No No No No No MPI - Number of connections 6 8 8 8 12 12 • Services - PG/OP communication Yes Yes Yes Yes Yes Yes - Routing No No No Yes No Yes - Global data communication Yes Yes Yes Yes Yes Yes - S7 basic communication Yes Yes Yes Yes Yes - S7 communication Yes Yes Yes Yes Yes Yes - S7 communication, as client No No; via CP and No; via CP and No No No loadable FB loadable FB - S7 communication, as server Yes Yes Yes Yes Yes Yes - Transmission rates, max. 187.5 kBit/s 187.5 kBit/s 187.5 kBit/s 187.5 kBit/s 187. kBit/s 187.5 kBit/s 2nd interface • Type of interface integrated RS 422/ 485 interface • Physical RS 422/ RS 485 (X.27) integrated RS 485 interface integrated RS 422/ 485 interface RS 485 RS 422/ RS 485 (X.27) integrated RS 485 interface RS 485 • Isolated Yes Yes Yes Yes • Power supply to interface No 200 mA 200 mA (15 to 30 V DC), max. Functionality -MPI No No No No -DP master No Yes No Yes - DP slave No Yes No Yes - Point-to-point connection Yes No Yes No DP master - Number of connections, max. 8; for PG/OP communication - Number of connections (of which reserved), max. 1 for PG, 1 for OP 12; for PG/OP communication 1 for PG, 1 for OP • Services - PG/OP communication Yes Yes - Routing Yes Yes - Global data communication No No - S7 basic communication No No - S7 communication No No - S7 communication, as client No No - S7 communication, as server No No - Equidistance support Yes Yes - SYNC/FREEZE Yes Yes - Activate/deactivate DP slaves Yes Yes - Direct data exchange (lateral communication) Yes Yes -DPV1 Yes Yes - Transmission rates, max. - 12 Mbit/s 12 Mbit/s - Number of DP slaves, max. - 32 32 4 Siemens ST 70 · 2005 4/13

SIMATIC S7-300 Central processing units CPU 312C to CPU 317F-2 DP 4 ■ Technical specifications (continued) 6ES7 312- 5BD01-0AB0 6ES7 313- 5BE01-0AB0 6ES7 313- 6BE01-0AB0 6ES7 313- 6CE01-0AB0 6ES7 314- 6BF01-0AB0 6ES7 314- 6CF01-0AB0 2nd interface (continued) • Address area - Inputs, max. 1 KByte 1 KByte -Outputs, max. 1 KByte 1 KByte • User data per DP Slave - Inputs, max. 244 Byte 244 Byte -Outputs, max. 244 Byte 244 Byte DP slave - Number of connections - 8 12 • Services - PG/OP communication Yes Yes - Routing Yes Yes - Global data communication No No - S7 basic communication No No - Direct data exchange (lateral communication) Yes Yes -DPV1 No No - GSD file - Current GSD - The file is available at http://www.ad. siemens.com/ support under Product Support - Current GSD - The file is available at http://www.ad. siemens.com/ support under Product Support - Transmission rates, max. - 12 kBit/s 12 kBit/s - Automatic baud rates search Yes Yes • Intermediate memory - Inputs 244 Byte 244 Byte -Outputs 244 Byte 244 Byte - Address areas, max. 32 32 - User data per address area, max. 32 Byte 32 Byte Point-to-point coupling - Transmission rates, max. 38.4 kBaud 38.4 kBit/s half duplex 19.2 kBaud full duplex - Length of cable, max. 1,200 m 1,200 m - Controllable interface from the user program Yes Yes - Interface can activate alarm/interrupt in the user program Yes; Message for Break ID - Protocol driver 3964 (R); ASCII 3964 (R); ASCII and RK 512 Yes 4/14 Siemens ST 70 · 2005

SIMATIC S7-<strong>300</strong><br />

Central processing units<br />

CPU 312C to CPU 317F-2 DP<br />

4<br />

■ Technical specifications (continued)<br />

6ES7 312-<br />

5BD01-0AB0<br />

6ES7 313-<br />

5BE01-0AB0<br />

6ES7 313-<br />

6BE01-0AB0<br />

6ES7 313-<br />

6CE01-0AB0<br />

6ES7 314-<br />

6BF01-0AB0<br />

6ES7 314-<br />

6CF01-0AB0<br />

2nd interface (continued)<br />

• Address area<br />

- Inputs, max. 1 KByte 1 KByte<br />

-Outputs, max. 1 KByte 1 KByte<br />

• User data per DP Slave<br />

- Inputs, max. 244 Byte 244 Byte<br />

-Outputs, max. 244 Byte 244 Byte<br />

DP slave<br />

- Number of connections - 8 12<br />

• Services<br />

- PG/OP communication Yes Yes<br />

- Routing Yes Yes<br />

- Global data communication No No<br />

- S7 basic communication No No<br />

- Direct data exchange<br />

(lateral communication)<br />

Yes<br />

Yes<br />

-DPV1 No No<br />

- GSD file - Current GSD -<br />

The file is<br />

available at<br />

http://www.ad.<br />

siemens.com/<br />

support under<br />

Product Support<br />

- Current GSD -<br />

The file is<br />

available at<br />

http://www.ad.<br />

siemens.com/<br />

support under<br />

Product Support<br />

- Transmission rates, max. - 12 kBit/s 12 kBit/s<br />

- Automatic baud rates search Yes Yes<br />

• Intermediate memory<br />

- Inputs 244 Byte 244 Byte<br />

-Outputs 244 Byte 244 Byte<br />

- Address areas, max. 32 32<br />

- User data per address area,<br />

max.<br />

32 Byte 32 Byte<br />

Point-to-point coupling<br />

- Transmission rates, max. 38.4 kBaud<br />

38.4 kBit/s<br />

half duplex<br />

19.2 kBaud full<br />

duplex<br />

- Length of cable, max. 1,200 m 1,200 m<br />

- Controllable interface from the<br />

user program<br />

Yes<br />

Yes<br />

- Interface can activate alarm/interrupt<br />

in the user program<br />

Yes; Message<br />

for Break ID<br />

- Protocol driver 3964 (R); ASCII 3964 (R); ASCII<br />

and RK 512<br />

Yes<br />