■ Technical specifications (continued) Integrated inputs/outputs Default addresses of the integral 6ES7 635- 2EC01-0AE3 6ES7 635- 2EB01-0AE3 - Digital inputs 124.0 to 126.7 124.0 to 126.7 - Digital outputs 124.0 to 125.7 124.0 to 125.7 - Analog inputs 752 to 761 752 to 761 - Analog outputs 752 to 755 752 to 755 Digital inputs • Number of digital inputs 24 24 - which can be used as inputs 16 16 for technological functions Number of inputs that can be driven in parallel • vertical mounting positions - up to 40°C 18 18 - up to 50°C 12 12 • 45°C mounting positions - up to 45°C 12 12 • horizontal mounting positions - up to 40°C 12 12 Length of cable - Length of cable shielded, max. 1,000 m; 100 m for technological functions - Length of cable unshielded, max. 600 m 600 m • Technological function - shielded, max. 50 m; at maximum count frequency - unshielded, max. Unshielded cables are not allowed for technological functions • Standard DI 1,000 m; 100 m for technological functions 50 m; at maximum count frequency Unshielded cables are not allowed for technological functions - shielded, max. 1,000 m 1,000 m - unshielded, max. 600 m 600 m • Input characteristic to comply Yes Yes with IEC 1131, Type 1 Input voltage - Rated value, DC 24 V 24 V - for signal "0" -3 to 5 V -3 to 5 V - for signal "1" 15 to 30 V 15 to 30 V Input current - for 1 signal, typical 7 mA 7 mA Input delay (at rated value of the input voltage) • For standard inputs - Parameterizable Yes; 0.1 / 0.5 / 3 / 5 ms - Rated value 3 ms 3 ms • for counters/technological functions - at 0 to 1, max. 8 µs 8 µs Yes; 0.1 / 0.5 / 3 / 15 ms Digital outputs SIMATIC C7 Control systems 6ES7 635- 2EC01-0AE3 C7-635 6ES7 635- 2EB01-0AE3 • Number of digital outputs 16 16 - of which fast outputs 4 4 • Length of cable shielded, max. 1,000 m 1,000 m • Length of cable unshielded, max. 600 m 600 m • Short-circuit protection of the output • Short-circuit prot ection of the output, response threshold, typical • Limitation of voltage induced on circuit interruption to Yes; clocking electronically 1 A 1 A Yes; clocking electronically L+ (-48 V) L+ (-48 V) • Lamp load, max. 5 W 5 W • Driving a digital input Yes Yes Output voltage - for 1 signal L+ (-0.8 V) L+ (-0.8 V) Output current - for 1 signal rated value 0.5 A 0.5 A - permissible range for signal "1", 5 mA 5 mA min. - permissible range for signal "1", 0.6 A 0.6 A max. - for 1 signal minimum load 5 mA 5 mA current - for 0 signal residual current, max. 0.5 mA 0.5 mA Parallel switching of 2 outputs - to increase power No No - to redundantly drive a load Yes Yes Switching frequency - at resistive load, max. 100 Hz 100 Hz - at inductive load, max. 0.5 Hz 0.5 Hz - at lamp load, max. 100 Hz 100 Hz - of pulse outputs, 2.5 kHz 2.5 kHz at resistive load, max. Summation current of the outputs (per group) • vertical mounting positions - up to 40°C., max. 3 A 3 A - up to 50°C., max. 2 A 2 A • 45°C mounting positions - up to 45°C, max. 2 A 2 A • horizontal mounting positions - up to 40°C., max. 2 A 2 A - up to 40 °C, max. 4 A 4 A - up to 60 °C, max. 2 A 2 A Load impedance range - lower limit 48 Ω 48 Ω - upper limit 4 kΩ 4 kΩ 6 Siemens ST 70 · 2005 6/17

6 SIMATIC C7 Control systems C7-635 ■ Technical specifications (continued) Analog inputs 6ES7 635- 2EC01-0AE3 6ES7 635- 2EB01-0AE3 • Number of analog inputs 4 4 • Number of analog inputs for 4 4 voltage/current measurement • Number of analog inputs for resistance/temperature 1 1 measurement) • Number of analog inputs for 1 1 resistance measurement • Length of cable shielded, max. 100 m 100 m • Permissible input voltage for the voltage input (destruction limit), max. • Permissible input voltage for the current input (destruction limit), max. • Permissible input voltage for the voltage input (destruction limit), max. • Permissible input voltage for the current input (destruction limit), max. • Technical unit for temperature measurement, adjustable 30 V; permanent 2.5 V; permanent, max. 24V transient 0.5 mA; permanent 50 mA; permanent Yes; degrees Celsius / degrees Fahrenheit / Kelvin 30 V; permanent 2.5 V; permanent, max. 24V transient 0.5 mA; permanent 50 mA; permanent Input ranges (rated values), voltages - 0 to +10 V Yes Yes - -10 V to +10 V Yes Yes Input ranges (rated values), currents - 0 to 20 mA Yes Yes - -20 to +20 mA Yes Yes - 4 to 20 mA Yes Yes Input ranges (rated values), resistances - Open-circuit voltage (DC), type 2.5 V 2.5 V - Current measurement, type. 1.8 mA to 3.3 mA - 0 to 600 ohms Yes Yes Input ranges (rated values), resistance thermometer - Pt 100 Yes Yes Characteristic curve linearization - parameterizable Yes; by the software Yes; degrees Celsius / degrees Fahrenheit / Kelvin 1.8 mA to 3.3 mA - for resistance thermometer Pt 100 Pt 100 Temperature compensation - parameterizable No No Yes; by the software 6ES7 635- 2EC01-0AE3 6ES7 635- 2EB01-0AE3 Analog outputs • Number of analog outputs 2 2 • Length of cable shielded, max. 200 m 200 m • Voltage output, short-circuit Yes Yes protection • Voltage output, short-circuit 55 mA 55 mA current, max • Current output, open-circuit 17 V 17 V voltage, max. Output ranges, voltage - 0 to 10 V Yes Yes - -10 to +10 V Yes Yes Output ranges, current - 0 to 20 mA Yes Yes - -20 to +20 mA Yes Yes - 4 to 20 mA Yes Yes Actuator connection - for voltage output 2-wire connection - for voltage output 4-wire connection - for current output 2-wire connection Yes; without cable resistance compensation No Yes Yes; without cable resistance compensation No Yes Burden resistance (in the nominal output range) - at voltage outputs, min. 1 kΩ 1 kΩ - at voltage outputs, 0.1 µF 0.1 µF capacitive load, max. - at current outputs, max. 300 Ω 300 Ω - at current outputs, 0.1 mH 0.1 mH inductive load, max. Destruction limit against voltages and currents applied from outside - Voltages at the outputs against MANA 16 V; permanent - Current (DC), max. 50 mA; permanent Analog value formation • Measuring principle Encoding of instantaneous values (successive approximation) Integration and conversion time/triggering per channel - with over-range (bits incl. sign), max. - Integration time parameterizable Yes; 2.5 / 16.6 / 20 ms - Permissible input frequency, max. 16 V; permanent 50 mA; permanent 12 Bit 12 Bit 400 Hz 400 Hz Encoding of instantaneous values (successive approximation) Yes; 2.5 / 16.6 / 20 ms - Conversion time (per channel) 1 ms 1 ms - Response time of the input filter 0.38 ms 0.38 ms - Basic execution time of the 1 ms 1 ms module (all channels enabled) Settling time - for resistive load 0.6 ms 0.6 ms - for capacitive load 1 ms 1 ms - for inductive load 0.5 ms 0.5 ms 6/18 Siemens ST 70 · 2005

6<br />

SIMATIC C7<br />

Control systems<br />

C7-635<br />

■ Technical specifications (continued)<br />

Analog inputs<br />

6ES7 635-<br />

2EC01-0AE3<br />

6ES7 635-<br />

2EB01-0AE3<br />

• Number of analog inputs 4 4<br />

• Number of analog inputs for 4 4<br />

voltage/current measurement<br />

• Number of analog inputs for resistance/temperature<br />

1 1<br />

measurement)<br />

• Number of analog inputs for 1 1<br />

resistance measurement<br />

• Length of cable shielded, max. 100 m 100 m<br />

• Permissible input voltage for the<br />

voltage input (destruction limit),<br />

max.<br />

• Permissible input voltage for the<br />

current input (destruction limit),<br />

max.<br />

• Permissible input voltage for the<br />

voltage input (destruction limit),<br />

max.<br />

• Permissible input voltage for the<br />

current input (destruction limit),<br />

max.<br />

• Technical unit for temperature<br />

measurement, adjustable<br />

30 V;<br />

permanent<br />

2.5 V;<br />

permanent,<br />

max. 24V<br />

transient<br />

0.5 mA;<br />

permanent<br />

50 mA;<br />

permanent<br />

Yes;<br />

degrees Celsius<br />

/ degrees<br />

Fahrenheit /<br />

Kelvin<br />

30 V;<br />

permanent<br />

2.5 V;<br />

permanent,<br />

max. 24V<br />

transient<br />

0.5 mA;<br />

permanent<br />

50 mA;<br />

permanent<br />

Input ranges (rated values),<br />

voltages<br />

- 0 to +10 V Yes Yes<br />

- -10 V to +10 V Yes Yes<br />

Input ranges (rated values),<br />

currents<br />

- 0 to 20 mA Yes Yes<br />

- -20 to +20 mA Yes Yes<br />

- 4 to 20 mA Yes Yes<br />

Input ranges (rated values),<br />

resistances<br />

- Open-circuit voltage (DC), type 2.5 V 2.5 V<br />

- Current measurement, type. 1.8 mA to<br />

3.3 mA<br />

- 0 to 600 ohms Yes Yes<br />

Input ranges (rated values),<br />

resistance thermometer<br />

- Pt 100 Yes Yes<br />

Characteristic curve linearization<br />

- parameterizable Yes;<br />

by the software<br />

Yes;<br />

degrees Celsius<br />

/ degrees<br />

Fahrenheit /<br />

Kelvin<br />

1.8 mA to<br />

3.3 mA<br />

- for resistance thermometer Pt 100 Pt 100<br />

Temperature compensation<br />

- parameterizable No No<br />

Yes;<br />

by the software<br />

6ES7 635-<br />

2EC01-0AE3<br />

6ES7 635-<br />

2EB01-0AE3<br />

Analog outputs<br />

• Number of analog outputs 2 2<br />

• Length of cable shielded, max. 200 m 200 m<br />

• Voltage output, short-circuit Yes<br />

Yes<br />

protection<br />

• Voltage output, short-circuit 55 mA 55 mA<br />

current, max<br />

• Current output, open-circuit 17 V 17 V<br />

voltage, max.<br />

Output ranges, voltage<br />

- 0 to 10 V Yes Yes<br />

- -10 to +10 V Yes Yes<br />

Output ranges, current<br />

- 0 to 20 mA Yes Yes<br />

- -20 to +20 mA Yes Yes<br />

- 4 to 20 mA Yes Yes<br />

Actuator connection<br />

- for voltage output 2-wire<br />

connection<br />

- for voltage output 4-wire<br />

connection<br />

- for current output 2-wire<br />

connection<br />

Yes;<br />

without cable<br />

resistance<br />

compensation<br />

No<br />

Yes<br />

Yes;<br />

without cable<br />

resistance<br />

compensation<br />

No<br />

Yes<br />

Burden resistance<br />

(in the nominal output range)<br />

- at voltage outputs, min. 1 kΩ 1 kΩ<br />

- at voltage outputs,<br />

0.1 µF 0.1 µF<br />

capacitive load, max.<br />

- at current outputs, max. <strong>300</strong> Ω <strong>300</strong> Ω<br />

- at current outputs,<br />

0.1 mH 0.1 mH<br />

inductive load, max.<br />

Destruction limit against voltages<br />

and currents applied from outside<br />

- Voltages at the outputs against<br />

MANA<br />

16 V;<br />

permanent<br />

- Current (DC), max. 50 mA;<br />

permanent<br />

Analog value formation<br />

• Measuring principle<br />

Encoding of<br />

instantaneous<br />

values (successive<br />

approximation)<br />

Integration and conversion<br />

time/triggering per channel<br />

- with over-range (bits incl. sign),<br />

max.<br />

- Integration time parameterizable Yes; 2.5 / 16.6 /<br />

20 ms<br />

- Permissible input frequency,<br />

max.<br />

16 V;<br />

permanent<br />

50 mA;<br />

permanent<br />

12 Bit 12 Bit<br />

400 Hz 400 Hz<br />

Encoding of<br />

instantaneous<br />

values (successive<br />

approximation)<br />

Yes; 2.5 / 16.6 /<br />

20 ms<br />

- Conversion time (per channel) 1 ms 1 ms<br />

- Response time of the input filter 0.38 ms 0.38 ms<br />

- Basic execution time of the 1 ms 1 ms<br />

module (all channels enabled)<br />

Settling time<br />

- for resistive load 0.6 ms 0.6 ms<br />

- for capacitive load 1 ms 1 ms<br />

- for inductive load 0.5 ms 0.5 ms<br />

6/18 Siemens ST 70 · 2005