SIMATIC C7 Control systems C7-635 ■ Technical specifications (continued) 6ES7 635- 2EC01-0AE3 Time synchronization - supported Yes Yes - on MPI, master Yes Yes - on MPI, slave Yes Yes - in AS, master Yes Yes S7 message functions • Number of stations that can log on for message functions, max. 12; (depending on the configured connections for PG/OP and S7 basic communication) • Process diagnostic messages Yes Yes • simultaneously active Alarm-S 40 40 blocks, max. Test and startup functions Status/modify - Variable Yes Yes -Variables Inputs, outputs, flags, DB, timers, counters - Number of variables, max. 30 30 - of which status variables, max. 30 30 - of which modify variables, max. 14 14 Forcing - Forcing Yes Yes - Forcing, variables Inputs, outputs - Forcing, number of variables, max. 10 10 6ES7 635- 2EB01-0AE3 12; (depending on the configured connections for PG/OP and S7 basic communication) Inputs, outputs, flags, DB, timers, counters Inputs, outputs • Status block Yes Yes • Single step Yes Yes • Number of breakpoints 2 2 • Number of entries in the diagnostic 100 100 buffer, max. Diagnostic buffer - available Yes Yes - Number of inputs, max. 100 100 - adjustable No No Communication functions • Number of logical connections (including the network), max. 4; 1 fixed with integral CPU 4; 1 fixed with integral CPU • PG/OP communication Yes Yes Global data communication - supported Yes Yes - Number of GD packets, max. 4 4 - Number of send GD packets, 4 4 max. - Number of receive GD packets, 4 4 max. - Size of GD packets, max. 22 Byte 22 Byte - Size of GD packets (of which consistent), max. 22 Byte 22 Byte 6ES7 635- 2EC01-0AE3 6ES7 635- 2EB01-0AE3 S7 basic communication - supported Yes Yes - User data per job 76 Byte 76 Byte - User data per job (of which consistent), max. 76 Byte; 76 bytes (for X_SEND and X_RECV) 64 bytes (for X_PUT and X_GET as server) S7 communication - supported Yes Yes - as server Yes Yes - as client Yes; via CP and loadable FB - User data per job, max. 180 KByte; at PUT/GET - User data per job (of which consistent), max. S5 compatible communication - supported Yes; via CP and loadable FB 64 Byte 64 Byte Number of connections - overall 12 12 - usable for PG communication 11 11 - reserved for PG communication 1 1 - Customizable for PG 1 1 communication, min. - customizable for PG 11 11 communication, max. - usable for OP communication 11 11 - reserved for OP communication 1 1 - Customizable for OP 1 1 communication, min. - customizable for OP 11 11 communication, max. - usable for S7 basic 8 8 communication - reserved for S7 basic 8 8 ommunication - Customizable for S7 basic 0 0 communication, min. - customizable for S7 basic 8 8 communication, max. - usable for routing 4 4 76 Byte; 76 bytes (for X_SEND and X_RECV) 64 bytes (for X_PUT and X_GET as server) Yes; via CP and loadable FB 180 KByte; at PUT/GET Yes; via CP and loadable FB 6 Siemens ST 70 · 2005 6/15

SIMATIC C7 Control systems C7-635 6 ■ Technical specifications (continued) Interfaces 6ES7 635- 2EC01-0AE3 6ES7 635- 2EB01-0AE3 • Number of printer interfaces 1; serial 1; serial 1st interface • Type of interface integrated RS 485 interface integrated RS 485 interface • Physical RS 485 RS 485 • Isolated No No • Power supply to interface 200 mA 200 mA (15 to 30 V DC), max. Functionality -MPI Yes Yes MPI - Number of connections 12 12 • Services - PG/OP communication Yes Yes - Routing Yes Yes - Global data communication Yes Yes - S7 basic communication Yes Yes - S7 communication Yes Yes - S7 communication, as client Yes; via CP and loadable FB Yes; via CP and loadable FB - S7 communication, as server Yes Yes - Transmission rates, max. 187.5 kBit/s 187.5 kBit/s 2nd interface • Type of interface integrated RS 485 interface integrated RS 485 interface • Physical RS485 RS485 • Isolated Yes Yes • Power supply to interface 200 mA 200 mA (15 to 30 V DC), max. • Number of connection resources 12 12 Functionality -MPI No No -DP master Yes Yes - DP slave Yes Yes DP master - Number of connections, max. 12 12 - Number of connections (of which reserved), max. 1 for PG, 1 for OP 1 for PG, 1 for OP • Services - PG/OP communication Yes Yes - Routing Yes Yes - Global data communication No No - S7 basic communication No No - S7 communication No No - S7 communication, as client No No - S7 communication, as server No No - Equidistance support Yes Yes - SYNC/FREEZE Yes Yes - Activate/deactivate Yes Yes DP slaves - Direct data exchange Yes Yes (lateral communication) - Transmission rates, max. 12 Mbit/s 12 Mbit/s - Number of DP slaves, max. 32 32 6ES7 635- 2EC01-0AE3 6ES7 635- 2EB01-0AE3 • Address area - Inputs, max. 1 KByte 1 KByte - Outputs, max. 1 KByte 1 KByte • User data per DP Slave - Inputs, max. 244 Byte 244 Byte - Outputs, max. 244 Byte 244 Byte DP master - Number of connections, max. • Services 12 12 - PG/OP communication Yes Yes - Routing Yes; only when interfaces active Yes; only when interfaces active - Global data communication No No - S7 basic communication No No - S7 communication No No - Direct data exchange Yes Yes (lateral communication) -DPV1 No No - Transmission rates, max. 12 Mbit/s 12 Mbit/s • Intermediate memory - Inputs 244 Byte 244 Byte -Outputs 244 Byte 244 Byte - Address areas, max. 32 32 - User data per address area, 32 Byte 32 Byte max. CPU/ programming Configuration software - ProTool Yes; or SIMATIC ProTool/Pro Configuration as of Version 6.0 SP1 - ProTool/Lite Yes Yes - ProTool/Pro Yes; Also flexible configuration with WinCC Programming language Yes; or SIMATIC ProTool/Pro Configuration as of Version 6.0 SP1 Yes; Also flexible configuration with WinCC -LAD Yes Yes -FBD Yes Yes -STL Yes Yes -SCL Yes Yes -CFC Yes Yes - GRAPH Yes Yes - HiGraph ® Yes Yes Software library • Instruction set see instruction list see instruction list • Bracket levels 8 8 • User program protection/password protection Yes Yes • System functions (SFC) • System function blocks (SFB) see instruction list see instruction list see instruction list see instruction list 6/16 Siemens ST 70 · 2005

SIMATIC C7<br />

Control systems<br />

C7-635<br />

■ Technical specifications (continued)<br />

6ES7 635-<br />

2EC01-0AE3<br />

Time synchronization<br />

- supported Yes Yes<br />

- on MPI, master Yes Yes<br />

- on MPI, slave Yes Yes<br />

- in AS, master Yes Yes<br />

S7 message functions<br />

• Number of stations that can log on<br />

for message functions, max.<br />

12;<br />

(depending on<br />

the configured<br />

connections for<br />

PG/OP and S7<br />

basic communication)<br />

• Process diagnostic messages Yes Yes<br />

• simultaneously active Alarm-S 40 40<br />

blocks, max.<br />

Test and startup functions<br />

Status/modify<br />

- Variable Yes Yes<br />

-Variables<br />

Inputs,<br />

outputs, flags,<br />

DB, timers,<br />

counters<br />

- Number of variables, max. 30 30<br />

- of which status variables, max. 30 30<br />

- of which modify variables, max. 14 14<br />

Forcing<br />

- Forcing Yes Yes<br />

- Forcing, variables Inputs,<br />

outputs<br />

- Forcing, number of variables,<br />

max.<br />

10 10<br />

6ES7 635-<br />

2EB01-0AE3<br />

12;<br />

(depending on<br />

the configured<br />

connections for<br />

PG/OP and S7<br />

basic communication)<br />

Inputs,<br />

outputs, flags,<br />

DB, timers,<br />

counters<br />

Inputs,<br />

outputs<br />

• Status block Yes Yes<br />

• Single step Yes Yes<br />

• Number of breakpoints 2 2<br />

• Number of entries in the diagnostic<br />

100 100<br />

buffer, max.<br />

Diagnostic buffer<br />

- available Yes Yes<br />

- Number of inputs, max. 100 100<br />

- adjustable No No<br />

Communication functions<br />

• Number of logical connections<br />

(including the <strong>net</strong>work), max.<br />

4; 1 fixed with<br />

integral CPU<br />

4; 1 fixed with<br />

integral CPU<br />

• PG/OP communication Yes Yes<br />

Global data communication<br />

- supported Yes Yes<br />

- Number of GD packets, max. 4 4<br />

- Number of send GD packets, 4 4<br />

max.<br />

- Number of receive GD packets, 4 4<br />

max.<br />

- Size of GD packets, max. 22 Byte 22 Byte<br />

- Size of GD packets<br />

(of which consistent), max.<br />

22 Byte 22 Byte<br />

6ES7 635-<br />

2EC01-0AE3<br />

6ES7 635-<br />

2EB01-0AE3<br />

S7 basic communication<br />

- supported Yes Yes<br />

- User data per job 76 Byte 76 Byte<br />

- User data per job<br />

(of which consistent), max.<br />

76 Byte;<br />

76 bytes<br />

(for X_SEND<br />

and X_RECV)<br />

64 bytes<br />

(for X_PUT and<br />

X_GET as<br />

server)<br />

S7 communication<br />

- supported Yes Yes<br />

- as server Yes Yes<br />

- as client Yes; via CP and<br />

loadable FB<br />

- User data per job, max. 180 KByte;<br />

at PUT/GET<br />

- User data per job<br />

(of which consistent), max.<br />

S5 compatible communication<br />

- supported Yes; via CP and<br />

loadable FB<br />

64 Byte 64 Byte<br />

Number of connections<br />

- overall 12 12<br />

- usable for PG communication 11 11<br />

- reserved for PG communication 1 1<br />

- Customizable for PG<br />

1 1<br />

communication, min.<br />

- customizable for PG<br />

11 11<br />

communication, max.<br />

- usable for OP communication 11 11<br />

- reserved for OP communication 1 1<br />

- Customizable for OP<br />

1 1<br />

communication, min.<br />

- customizable for OP<br />

11 11<br />

communication, max.<br />

- usable for S7 basic<br />

8 8<br />

communication<br />

- reserved for S7 basic<br />

8 8<br />

ommunication<br />

- Customizable for S7 basic 0 0<br />

communication, min.<br />

- customizable for S7 basic 8 8<br />

communication, max.<br />

- usable for routing 4 4<br />

76 Byte;<br />

76 bytes<br />

(for X_SEND<br />

and X_RECV)<br />

64 bytes<br />

(for X_PUT and<br />

X_GET as<br />

server)<br />

Yes; via CP and<br />

loadable FB<br />

180 KByte;<br />

at PUT/GET<br />

Yes; via CP and<br />

loadable FB<br />

6<br />

Siemens ST 70 · 2005<br />

6/15

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!