09.09.2015 Views

simatic s7-300 - megaelektrik.net

simatic s7-300 - megaelektrik.net

simatic s7-300 - megaelektrik.net

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SIMATIC C7<br />

Control systems<br />

C7-635<br />

6<br />

■ Technical specifications (continued)<br />

Timers/counters and<br />

their retentive characteristics<br />

6ES7 635-<br />

2EC01-0AE3<br />

6ES7 635-<br />

2EB01-0AE3<br />

S7 counter<br />

-Number 256 256<br />

• Retentivity<br />

- adjustable Yes Yes<br />

- preset from Z 0 to Z 7 from Z 0 to Z 7<br />

• Counting range<br />

- lower limit 0 0<br />

- upper limit 999 999<br />

IEC counter<br />

- available Yes Yes<br />

- Type SFB,<br />

unlimited<br />

quantity (only<br />

limited by working<br />

memory)<br />

-Number<br />

Unlimited (limited<br />

only by the<br />

main memory)<br />

SFB,<br />

unlimited<br />

quantity (only<br />

limited by working<br />

memory)<br />

Unlimited (limited<br />

only by the<br />

main memory)<br />

S7 times<br />

-Number 256 256<br />

• Retentivity<br />

- adjustable Yes Yes<br />

- preset No retention No retention<br />

• Timing range<br />

- lower limit 10 ms 10 ms<br />

- upper limit 9,990 s 9,990 s<br />

IEC timer<br />

- available Yes Yes<br />

- Type SFB, unlimited<br />

quantity (only<br />

limited by working<br />

memory)<br />

-Number<br />

Unlimited (limited<br />

only by the<br />

main memory)<br />

Data areas and their<br />

retentive characteristics<br />

SFB, unlimited<br />

quantity (only<br />

limited by working<br />

memory)<br />

Unlimited (limited<br />

only by the<br />

main memory)<br />

• Retentive data area as a whole, All<br />

All<br />

max.<br />

Flags<br />

-Number 256 Byte 256 Byte<br />

- adjustable retentivity Yes Yes<br />

- preset retentivity MB 0 to MB 15 MB 0 to MB 15<br />

- Number of clock memories 8;<br />

(1 memory<br />

byte)<br />

8;<br />

(1 memory<br />

byte)<br />

Data blocks<br />

- Number, max. 511 511<br />

- Size, max. 16 KByte 16 KByte<br />

Local data<br />

- per priority class, max. 510 Byte 510 Byte<br />

Address area<br />

6ES7 635-<br />

2EC01-0AE3<br />

6ES7 635-<br />

2EB01-0AE3<br />

I/O address area<br />

- Inputs 1 KByte 1 KByte<br />

-Outputs 1 KByte 1 KByte<br />

Process image<br />

- Inputs 128 Byte 128 Byte<br />

-Outputs 128 Byte 128 Byte<br />

Digital channels<br />

- integrated channels (DI) 24 24<br />

- integrated channels (DO) 16 16<br />

- Inputs 8.192 8.192<br />

-Outputs 8.192 8.192<br />

- Inputs, of which central 922 922<br />

- Outputs, of which central 922 922<br />

Analog channels<br />

- integrated channels (AI) 4; and 1x PT100 4; and 1x PT100<br />

- integrated channels (AO) 2 2<br />

- Inputs 512 512<br />

-Outputs 512 512<br />

- Inputs, of which central 248 248<br />

- Outputs, of which central 248 248<br />

Configuration<br />

• Number of modules per system, 23 23<br />

max.<br />

• Racks, max. 4 4<br />

• Modules per rack, max. 4;<br />

4 in subrack 0,<br />

8 in subracks 1<br />

and 2,<br />

7 in subrack 3<br />

Number of DP masters<br />

- integral 1 1<br />

- via CP 1 1<br />

Number of FMs and CPs that can<br />

be operated (recommendation)<br />

-FM 8 8<br />

- CP, point-to-point 8 8<br />

- CP, LAN 10 10<br />

Time<br />

Clock<br />

- Hardware clock (realtime clock) Yes Yes<br />

- buffered Yes Yes<br />

- Backup duration 6 week(s);<br />

(at 40 °C<br />

ambient<br />

temperature)<br />

- Deviation per day, max 10 s 10 s<br />

Run-time meter<br />

- Quantity 1 1<br />

- Number 0 0<br />

- Range of values 0 to 2^31<br />

hours<br />

(when using<br />

SFC 101)<br />

4;<br />

4 in subrack 0,<br />

8 in subracks 1<br />

and 2,<br />

7 in subrack 3<br />

6 week(s);<br />

(at 40 °C<br />

ambient<br />

temperature)<br />

0 to 2^31<br />

hours<br />

(when using<br />

SFC 101)<br />

- Granularity 1 hour 1 hour<br />

- retentive Yes; must be<br />

restarted on<br />

each complete<br />

restart<br />

Yes; must be<br />

restarted on<br />

each complete<br />

restart<br />

6/14 Siemens ST 70 · 2005

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!