SIMATIC C7<br />

Control systems<br />

C7-613<br />

■ Technical specifications (continued)<br />

Digital outputs<br />

6ES7 613-1CA01-0AE3<br />

• Number of digital outputs 16<br />

• Length of cable shielded, max. 1,000 m<br />

• Length of cable unshielded, max. 600 m<br />

• Short-circuit protection of the output Yes; clocking electronically<br />

• Limitation of voltage induced on L+ (-48 V)<br />

circuit interruption to<br />

Output voltage<br />

- for 1 signal L+ (-0.8 V)<br />

Output current<br />

- for 1 signal permissible range 0.5 A<br />

for 0 to 40 °C, max.<br />

- for 1 signal permissible range 0.5 A<br />

for 40 to 60 °C, max.<br />

- for 1 signal minimum load current 5 mA<br />

- for 0 signal residual current, max. 0.5 mA<br />

Switching frequency<br />

- at resistive load, max. 100 Hz<br />

- at inductive load, max. 0.5 Hz<br />

Summation current of the outputs<br />

(per group)<br />

• horizontal mounting positions<br />

- up to 40 °C, max. 4,000 mA<br />

- up to 60 °C, max. 2,000 mA<br />

Analog inputs<br />

• Number of analog inputs 4<br />

• Number of analog inputs for voltage/current<br />

measurement<br />

4<br />

• Number of analog inputs for resistance/temperature<br />

measurement<br />

1<br />

Input ranges (rated values), voltages<br />

- 0 to +10 V Yes<br />

- -10 V to +10 V Yes<br />

Input ranges (rated values), currents<br />

- 0 to 20 mA Yes<br />

- -20 to +20 mA Yes<br />

- 4 to 20 mA Yes<br />

Input ranges (rated values),<br />

resistances<br />

- 0 to 600 ohms Yes<br />

Input ranges (rated values),<br />

resistance thermometer<br />

- Pt 100 Yes<br />

Analog outputs<br />

• Number of analog outputs 2<br />

Output ranges, voltage<br />

- 0 to 10 V Yes<br />

- -10 to +10 V Yes<br />

Output ranges, current<br />

- 0 to 20 mA Yes<br />

- -20 to +20 mA Yes<br />

- 4 to 20 mA Yes<br />

Analog value formation<br />

Integration and conversion<br />

time/triggering per channel<br />

- with over-range<br />

12 Bit<br />

(bits incl. sign), max.<br />

- Integration time parameterizable Yes; 2.5 / 16.6 / 20 ms<br />

- Conversion time (per channel) 1 ms<br />

6ES7 613-1CA01-0AE3<br />

Sensor<br />

Connectable encoders<br />

- 2-wire BEROS Yes<br />

- permissible closed-circuit current 1.5 mA<br />

(2-wire BEROS), max.<br />

Error/accuracies<br />

Basic error limit<br />

(operational limit at 25 °C)<br />

- relative to the output range, +/- 0.7 %<br />

voltage<br />

- relative to the output range, +/- 0.7 %<br />

current<br />

- relative to the input range, +/- 0.7 %<br />

voltage<br />

- relative to the input range, +/- 0.7 %<br />

current<br />

- relative to the input range, +/- 3 %<br />

resistance<br />

- relative to the input range, +/- 3 %<br />

resistance thermometer<br />

Integral functions<br />

• Number of counters 3<br />

• Count frequency (counters) max. 30 kHz<br />

• Frequency measurement<br />

Yes<br />

• PID controller<br />

Yes<br />

• Number of pulse outputs 3<br />

• Cut-off frequency (pulse)<br />

2.5 kHz<br />

Operator control and monitoring<br />

• Graphic objects<br />

Yes<br />

• Info texts Yes; 128<br />

• Messages<br />

Yes; with buffer<br />

• Number of process pictures 128<br />

• Number of variables per picture, 8<br />

max.<br />

• Password protection<br />

Yes<br />

Keyboard<br />

- Number of operating cycle keys 1,000,000<br />

- Number of function keys 10; can be used at same time<br />

as numeric input<br />

- Number of softkey keys 4<br />

Display<br />

- Type LCD backlit<br />

- Number of lines 4<br />

- Number of characters per line 20<br />

- Background lighting MTBF 100,000 h<br />

(at 20°C)<br />

Potentials/ electrical isolation<br />

Analog output functions<br />

- Electrical isolation, analog output Yes; common for analog I/O<br />

functions<br />

Analog output functions<br />

- Electrical isolation, analog inputs Yes; common for analog I/O<br />

Digital output functions<br />

- between the channels Yes<br />

- between the channels, in groups 8<br />

of<br />

Digital input functions<br />

- between the channels Yes<br />

- between the channels,<br />

8; and 16<br />

in groups of<br />

6<br />

Siemens ST 70 · 2005<br />