simatic s7-300 - megaelektrik.net
simatic s7-300 - megaelektrik.net
simatic s7-300 - megaelektrik.net
- No tags were found...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
SIMATIC S7-400<br />
Connection methods<br />
Fully modular connection<br />
■ Benefits<br />
5<br />
• Simple plug connections for front connector module, cable<br />
and terminal block<br />
• Fast, low-cost wiring<br />
• Power supply for digital and analog modules can be<br />
connected to the front connector module or terminal block<br />
• Reduction in wiring errors, clear control cabi<strong>net</strong> wiring<br />
• Byte-oriented signal distribution with digital modules<br />
• Each component can be replaced individually<br />
• Any cable length can be configured without waste<br />
■ Technical specifications<br />
Technical specifications for front connector module<br />
Rated operating voltage<br />
24 V DC<br />
Max. permitted operating voltage 60 V DC<br />
Max. permitted continuous current<br />
• per connector pin<br />
1 A<br />
Max. permitted summation current 4 A/byte (voltage infeed)<br />
Permissible ambient air temperature 0 °C to + 60 °C<br />
Test voltage<br />
0.5 kV, 50 Hz, 60 s<br />
Air and creepage distances IEC 664 (1980), IEC 664 A (1981),<br />
in accordance with<br />
DIN VDE 0110 (01.89),<br />
overvoltage class II,<br />
pollution degree 2<br />
Terminal blocks for 1-wire connection and 3-wire initiators<br />
Max. operating voltage<br />
60 V DC<br />
Continuous current per signal 1 A<br />
Max. summation current<br />
4 A/byte<br />
(voltage input)<br />
Operating temperature 0 °C to + 60 °C<br />
Mounting position<br />
Any<br />
Air and creepage distances IEC Report 664, IEC 664 A,<br />
IEC 1131 T2,<br />
CSA C22.2 No 142 UL 508,<br />
VDE 0160 (12.90),<br />
overvoltage category II,<br />
pollution severity 3<br />
Dimensions (W x H x D) in mm<br />
• 1-wire connection<br />
Approx. 51 x 41 x 55<br />
6ES7924-0AA00-_A_0<br />
• For 3-wire initiators<br />
Approx. 60 x 41 x 70<br />
6ES7924-0CA00-_A_0<br />
Terminal blocks with relay 8S<br />
Field circuit side<br />
Coil operating voltage<br />
24 V DC<br />
Input connections<br />
None<br />
Contact side<br />
Number of relay outputs<br />
8 (NO contacts)<br />
Contact design<br />
Single contact, 1 NO<br />
Switching capacity (resistive load) Max. 2 A/250 V AC,<br />
max. 2 A/30 V DC<br />
max. 0.2 A/60 V DC<br />
Recommended minimum load ≥<br />
100 mA<br />
Switching frequency<br />
6 cycles/minute<br />
Service life<br />
• Mechanical<br />
10 x 10 6 switching operations<br />
• Electrical<br />
600 x 10 3 switching operations at<br />
230 V AC/2 A/ power factor = 1<br />
Operating temperature 0 °C to +60 °C<br />
Mounting position<br />
Horizontal, ventilation slots<br />
upwards and downwards.<br />
To permit heat dissipation, a<br />
space of at least 30 mm must be<br />
left above and below the relay terminal<br />
block<br />
Air and creepage distances IEC 1131-2 (1992), EN 50 178<br />
(4/98) overvoltage category III,<br />
pollution severity 2 between trigger<br />
circuit and relay contacts:<br />
5.5 mm between contact groups<br />
K0-K3 and K4-K7: 5.5 mm within<br />
a contact group: 3.2 mm<br />
UL and CSA available soon<br />
Terminal blocks can be removed for<br />
independent wiring<br />
• For 24 V power supply for digital 4-pole terminal block<br />
modules<br />
• For relay outputs<br />
Two 8-pole terminal blocks<br />
Dimensions (W x H x D) in mm Approx. 60 x 68 x 78<br />
6ES7924-0CD00-_A_0<br />
5/90 Siemens ST 70 · 2005