SIMATIC S7-<strong>300</strong><br />
Central processing units<br />
CPU 312C to CPU 317F-2 DP<br />
■ Technical specifications (continued)<br />
6ES7 315-<br />
6FF01-0AB0<br />
CPU/blocks<br />
DB<br />
- Number, max. 1,023; DB 0<br />
reserved<br />
6ES7 317-<br />
6FF00-0AB0<br />
2,047; DB 0<br />
reserved<br />
- Size, max. 16 KByte 64 KByte<br />
FB<br />
- Number, max. 2,048; see<br />
instruction list<br />
2,048; see<br />
instruction list<br />
- Size, max. 16 KByte 64 KByte<br />
FC<br />
- Number, max. 2,048; See<br />
instruction list<br />
2,048; see<br />
instruction list<br />
- Size, max. 16 KByte 64 KByte<br />
OB<br />
- Number, max. see<br />
instruction list<br />
see<br />
instruction list<br />
- Size, max. 16 KByte 64 KByte<br />
Nesting depth<br />
- per priority class 8 8<br />
- additional levels within an<br />
error OB<br />
4 4<br />
CPU/processing times<br />
• for bit instruction, min. 0.1 µs 0.1 µs<br />
• for word instruction, min. 0.2 µs 0.1 µs<br />
• for integer math, min. 2 µs 0.2 µs<br />
• for floating-point math, min. 6 µs 2 µs<br />
Timers/counters and their<br />
retentive characteristics<br />
S7 counter<br />
-Number 256 512<br />
• of which retentive without battery<br />
- adjustable Yes Yes<br />
• Counting range<br />
- lower limit 0 0<br />
- upper limit 999 999<br />
IEC counter<br />
- available Yes Yes<br />
- Type SFB SFB<br />
S7 times<br />
-Number 256 512<br />
• Retentivity<br />
- adjustable Yes Yes<br />
- preset<br />
No retention No retention<br />
• Timing range<br />
- lower limit 10 ms 10 ms<br />
- upper limit 9,990 s 9,990 s<br />
IEC timer<br />
- available Yes Yes<br />
- Type SFB SFB<br />
6ES7 315-<br />
6FF01-0AB0<br />
6ES7 317-<br />
6FF00-0AB0<br />
Data areas and their retentive<br />
characteristics<br />
Flags<br />
- Number 2,048 Byte 4,096 Byte<br />
- adjustable retentivity Yes; MB 0<br />
to MB 2047<br />
- Number of clock memories 8;<br />
1 memory byte<br />
Data blocks<br />
- Number, max. 1,023; DB 0<br />
reserved<br />
Yes; MB 0<br />
to MB 4095<br />
8;<br />
1 memory byte<br />
2,047; DB 0<br />
reserved<br />
- Size, max. 16 KByte 64 KByte<br />
Local data<br />
- per priority class, max. 1,024 Byte 1,024 Byte<br />
Address area<br />
I/O address area<br />
- Inputs 2 KByte 8 KByte<br />
-Outputs 2 KByte 8 KByte<br />
• of which distributed<br />
- Inputs 2 KByte 8 KByte<br />
-Outputs 2 KByte 8 KByte<br />
Process image<br />
- Inputs 384 Byte 1,024 Byte<br />
-Outputs 384 Byte 1,024 Byte<br />
Digital channels<br />
- Inputs 16,384 65,536<br />
-Outputs 16,384 65,536<br />
- Inputs, of which central 1,024 1,024<br />
- Outputs, of which central 1,024 1,024<br />
Analog channels<br />
- Inputs 1,024 1,024<br />
-Outputs 1,024 1,024<br />
- Inputs, of which central 256 256<br />
- Outputs, of which central 256 256<br />
Configuration<br />
• Racks, max. 4 4<br />
• Modules per rack, max. 8 8<br />
Number of DP masters<br />
- integral 1 2<br />
- via CP 1 2<br />
Number of FMs and CPs that can<br />
be operated (recommendation)<br />
-FM 8 8<br />
- CP, point-to-point 8 8<br />
- CP, LAN 10 10<br />
4/32 Siemens ST 70 · 2005