SIMATIC S7-400<br />

Communication<br />

CP 443-1 IT<br />

■ Overview<br />

• The connection for the SIMATIC S7-400 to Industrial Ether<strong>net</strong><br />

- 10/100 Mbit/s full/half duplex connection with autosensing<br />

for automatic switchover between AUI, ITP and RJ45 interface<br />

- universal connection options for ITP, RJ45 and AUI<br />

- Multi-protocol operation for ISO, TCP/IP and UDP<br />

- Adjustable Keep Alive function<br />

• Communication services:<br />

- Programming device/operator panel communication<br />

- S7 communication<br />

- S5-compatible communication<br />

- IT communication<br />

• Web-function for access to process data via Web browser<br />

• E-mail function for sending electronic messages via the<br />

S7-400.<br />

• FTP communication permits pr ogram-controlled FTP client<br />

communication,<br />

access to data blocks via FTP server<br />

• Multicast for UPD<br />

• Cross-<strong>net</strong>work programming device/operator panel<br />

communication through S7 routing<br />

• Remote programming and init ial startup via the <strong>net</strong>work<br />

5<br />

■ Technical specifications<br />

Data transmission rate<br />

Interfaces<br />

• Connection to Industrial<br />

Ether<strong>net</strong><br />

- AUI (10 Mbit/s)<br />

- ITP (10/100 Mbit/s)<br />

• 10BaseT, 100BaseTX<br />

Current consumption<br />

• from DC + 5V ( ±5%)<br />

• from DC +24V ( ±5%)<br />

Power loss<br />

10/100 Mbit/s autosensing<br />

15-pin Sub-D socket<br />

RJ45<br />

approx. 1.5 A<br />

typ. 220 mA<br />

max. 340 mA<br />

9.1 W<br />

Perm. ambient conditions<br />

• Operating temperature 0 °C to +60 °C<br />

• Transport/storage temperature -40 °C to +70 °C<br />

• Relative humidity Max. 95% at +25 °C<br />

Construction<br />

• Module format<br />

Compact module S7-400, single<br />

width<br />

• Dimensions (WxHxD) in mm 25 x 290 x 210<br />

• Weight<br />

Approx. 700 g<br />

Configuring software<br />

NCM S7 for Industrial Ether<strong>net</strong> V5<br />

or higher (included in the scope<br />

of delivery of STEP 7 V5.x).<br />

Performance data<br />

IT communication<br />

Number of connections to an e-mail Max. 1<br />

server<br />

FTP communication<br />

Number of client connections Max. 10<br />

Number of server connections Max. 2<br />

Capacity of flash memory file system<br />

10 MB<br />

Service life of the Flash Memory 10,000 write cycles<br />

cells<br />

S5-compatible communication<br />

(SEND/RECEIVE)<br />

• Sum of all simultaneously operable Max. 64<br />

ISO/TCP/UDP connections<br />

• Useful data<br />

- ISO or TCP/IP Max. 8 KB<br />

- UDP Max. 2 Kbyte<br />

- E-mail Max. 2 Kbyte<br />

S7 and programmable device/<br />

operator panel communication<br />

• Number of connections 1) Max. 48<br />

Multi-protocol operation<br />

• Sum of all simultaneously operable Max. 64<br />

connections<br />

1) Use depends on performance of S7-CPU/FM used.<br />