simatic s7-300 - megaelektrik.net
simatic s7-300 - megaelektrik.net simatic s7-300 - megaelektrik.net
SIMATIC S7-400 Communication CP 443-5 Extended ■ Overview • DP V1 master connection of S7-400 to PROFIBUS • For configuring additional PROFIBUS DP lines • Communication services: - PROFIBUS DP - PG/OP communication - S7 communication - S5-compatible communication (SEND/RECEIVE) • Time-of-day synchronization • Simple configuration and programming using PROFIBUS • PG communication between networks through S7 routing • Easy to integrate into the SIMATIC S7-400 system • Module replacement without the need for a programming device. • Operation in the SIMATIC H system for redundant S7 communication or DP master communication • Data record routing (PROFIBUS DP) • Add or change distributed I/O during normal operation 5 ■ Technical specifications Data transmission rate 9.6 kbit/s to 12 Mbit/s Interfaces •Ports 9-pin Sub-D socket (RS 485) Power supply 5 V DC ± 5% 24 V DC ±5% Current input from 5 V DC 1.3 A Power loss 6.5 W Perm. ambient conditions • Operating temperature 0 °C to +60 °C • Transport/storage temperature -40 °C to +70 °C • Relative humidity Max. 95% at +25°C Construction • Dimensions (WxHxD) in mm 25 x 290 x 210 • Weight Approx. 700 g Number of external DP-lines in one 10 central rack Performance data for DP master function • DP master DP-V1 • Number of operable DP slaves Max. 125 • Size of DP data areas overall - DP input area Max. 4 KB - DP output range Max. 4 KB • Size of DP data areas per connected DP slave - DP input area Max. 244 bytes - DP output range Max. 244 bytes Performance data for S7 communication • Number of connections that can 16 to 48 1) be used Performance data for S5-compatible communication (SEND/RECEIVE) • Number of connections that can Max. 32 be used • Useful data / connection max. 240 bytes (SEND and RECEIVE) Multi-protocol operation • Number of connections that can used (2 of which are reserved for PG/OP communication) - Without DP Max. 59 - With DP Max. 55 1) Dependent on CPU type Siemens ST 70 · 2005 5/75
SIMATIC S7-400 Communication CP 443-5 Extended ■ Ordering data Order No. Order No. CP 443-5 Extended communications processor For connection of SIMATIC S7-400 to PROFIBUS Extended version for PROFIBUS DP; with electronic manual on CD-ROM 6GK7 443-5DX03-0XE0 PROFIBUS FastConnect RS 485 bus connector With 90° cable outlet; With insulation displacement method, max. data transmission rate 12 Mbit/s • without PG interface 6ES7 972-0BA50-0XA0 5 NCM S7 configuration software for PROFIBUS Configuration software for PROFIBUS CPs for SIMATIC S7 V5.1 and newer executable under STEP 7 V5.1; with electronic manual on CD-ROM English, French, German, Italian and Spanish "NCM S7 for PROFIBUS" manual Paper version for V5.x (STEP 7 V5.x) • German Delivered with STEP 7 Version 5 6GK7 080-5AA04-8AA0 • with PG interface PROFIBUS bus connector IP20 For connection to PPI, MPI, PROFIBUS • without PG interface • with PG interface PROFIBUS 12M bus terminal Bus terminal for connecting PROFIBUS stations up to 12 Mbit/s with connecting cable "Communication with SIMATIC" manual • German 6ES7 972-0BB50-0XA0 6ES7 972-0BA12-0XA0 6ES7 972-0BB12-0XA0 6GK1 500-0AA10 6ES7 398-8EA00-8AA0 • English 6GK7 080-5AA04-8BA0 •English 6ES7 398-8EA00-8BA0 • French 6GK7 080-5AA04-8CA0 • French 6ES7 398-8EA00-8CA0 • Spanish 6GK7 080-5AA04-8DA0 • Spanish 6ES7 398-8EA00-8DA0 •Italian 6GK7 080-5AA04-8EA0 • Italian 6ES7 398-8EA00-8EA0 5/76 Siemens ST 70 · 2005
- Page 187 and 188: SIMATIC S7-400 Central processing u
- Page 189 and 190: SIMATIC S7-400 Central processing u
- Page 191 and 192: SIMATIC S7-400 Central processing u
- Page 193 and 194: SIMATIC S7-400 Central processing u
- Page 195 and 196: SIMATIC S7-400 Digital modules Digi
- Page 197 and 198: SIMATIC S7-400 Digital modules Digi
- Page 199 and 200: SIMATIC S7-400 Digital modules Digi
- Page 201 and 202: SIMATIC S7-400 Analog modules Analo
- Page 203 and 204: SIMATIC S7-400 Analog modules Analo
- Page 205 and 206: SIMATIC S7-400 Analog modules Analo
- Page 207 and 208: SIMATIC S7-400 Analog modules Analo
- Page 209 and 210: SIMATIC S7-400 Function modules FM
- Page 211 and 212: 5 SIMATIC S7-400 Function modules F
- Page 213 and 214: SIMATIC S7-400 Function modules Cam
- Page 215 and 216: SIMATIC S7-400 Function modules FM
- Page 217 and 218: SIMATIC S7-400 Function modules FM
- Page 219 and 220: SIMATIC S7-400 Function modules FM
- Page 221 and 222: SIMATIC S7-400 Function modules FM
- Page 223 and 224: SIMATIC S7-400 Function modules EXM
- Page 225 and 226: SIMATIC S7-400 Function modules EXM
- Page 227 and 228: SIMATIC S7-400 Function modules Acc
- Page 229 and 230: SIMATIC S7-400 Function modules Acc
- Page 231 and 232: SIMATIC S7-400 SIMATIC S5 intellige
- Page 233 and 234: SIMATIC S7-400 Communication CP 440
- Page 235 and 236: SIMATIC S7-400 Communication CP 441
- Page 237: SIMATIC S7-400 Communication CP 443
- Page 241 and 242: SIMATIC S7-400 Communication CP 443
- Page 243 and 244: SIMATIC S7-400 Communication CP 443
- Page 245 and 246: SIMATIC S7-400 Communication CP 443
- Page 247 and 248: SIMATIC S7-400 Modules for SIMATIC
- Page 249 and 250: SIMATIC S7-400 Modules for SIMATIC
- Page 251 and 252: SIMATIC S7-400 Modules for SIMATIC
- Page 253 and 254: SIMATIC S7-400 Connection methods F
- Page 255 and 256: SIMATIC S7-400 Connection methods 5
- Page 257 and 258: SIMATIC S7-400 Racks Racks ■ Orde
- Page 259 and 260: 5 SIMATIC S7-400 Racks Expansion ra
- Page 261 and 262: SIMATIC S7-400 Interface modules IM
- Page 263 and 264: SIMATIC S7-400 Interface modules IM
- Page 265 and 266: SIMATIC S7-400 Interface modules IM
- Page 267 and 268: SIMATIC S7-400 Interface modules IM
- Page 269 and 270: SIMATIC S7-400 Power supplies Power
- Page 271 and 272: SIMATIC S7-400 Accessories Labeling
- Page 273 and 274: SIMATIC S7-400 5 5/110 Siemens ST 7
- Page 275 and 276: SIMATIC C7 SIMATIC C7 Introduction
- Page 277 and 278: SIMATIC C7 Control systems C7-613 6
- Page 279 and 280: SIMATIC C7 Control systems C7-613 6
- Page 281 and 282: 6 SIMATIC C7 Control systems C7-633
- Page 283 and 284: SIMATIC C7 Control systems C7-633 6
- Page 285 and 286: SIMATIC C7 Control systems C7-633 6
- Page 287 and 288: SIMATIC C7 Control systems C7-635 6
SIMATIC S7-400<br />
Communication<br />
CP 443-5 Extended<br />
■ Overview<br />
• DP V1 master connection of S7-400 to PROFIBUS<br />
• For configuring additional PROFIBUS DP lines<br />
• Communication services:<br />
- PROFIBUS DP<br />
- PG/OP communication<br />
- S7 communication<br />
- S5-compatible communication (SEND/RECEIVE)<br />
• Time-of-day synchronization<br />
• Simple configuration and programming using PROFIBUS<br />
• PG communication between <strong>net</strong>works through S7 routing<br />
• Easy to integrate into the SIMATIC S7-400 system<br />
• Module replacement without the need for a programming<br />
device.<br />
• Operation in the SIMATIC H system for redundant S7<br />
communication or DP master communication<br />
• Data record routing (PROFIBUS DP)<br />
• Add or change distributed I/O during normal operation<br />
5<br />
■ Technical specifications<br />
Data transmission rate<br />
9.6 kbit/s to 12 Mbit/s<br />
Interfaces<br />
•Ports 9-pin Sub-D socket (RS 485)<br />
Power supply 5 V DC ± 5%<br />
24 V DC ±5%<br />
Current input from 5 V DC<br />
1.3 A<br />
Power loss<br />
6.5 W<br />
Perm. ambient conditions<br />
• Operating temperature 0 °C to +60 °C<br />
• Transport/storage temperature -40 °C to +70 °C<br />
• Relative humidity<br />
Max. 95% at +25°C<br />
Construction<br />
• Dimensions (WxHxD) in mm 25 x 290 x 210<br />
• Weight<br />
Approx. 700 g<br />
Number of external DP-lines in one 10<br />
central rack<br />
Performance data for DP master<br />
function<br />
• DP master<br />
DP-V1<br />
• Number of operable DP slaves Max. 125<br />
• Size of DP data areas overall<br />
- DP input area Max. 4 KB<br />
- DP output range Max. 4 KB<br />
• Size of DP data areas per<br />
connected DP slave<br />
- DP input area Max. 244 bytes<br />
- DP output range Max. 244 bytes<br />
Performance data<br />
for S7 communication<br />
• Number of connections that can 16 to 48 1)<br />
be used<br />
Performance data<br />
for S5-compatible communication<br />
(SEND/RECEIVE)<br />
• Number of connections that can Max. 32<br />
be used<br />
• Useful data / connection<br />
max. 240 bytes<br />
(SEND and RECEIVE)<br />
Multi-protocol operation<br />
• Number of connections that can<br />
used (2 of which are reserved<br />
for PG/OP communication)<br />
- Without DP Max. 59<br />
- With DP Max. 55<br />
1) Dependent on CPU type<br />
Siemens ST 70 · 2005<br />
5/75