4<br />

SIMATIC S7-<strong>300</strong><br />

Central processing units<br />

CPU 312C to CPU 317F-2 DP<br />

■ Technical specifications (continued)<br />

6ES7 317-<br />

2EJ10-0AB0<br />

6ES7 317-<br />

6TJ10-0AB0<br />

Process image<br />

- Inputs 256 Byte 256 Byte<br />

-Outputs<br />

256 Byte 256 Byte<br />

- Inputs, adjustable<br />

2,048 KByte<br />

- Outputs, adjustable 2,048 KByte<br />

- Inputs, preset 256 Byte<br />

- Outputs, preset 256 Byte<br />

Digital channels<br />

- Inputs 65,536 65,636<br />

-Outputs<br />

65,536 65,636<br />

- Inputs, of which central 1.024 256<br />

- Outputs, of which central<br />

1.024 256<br />

Analog channels<br />

- Inputs 4,096 4,096<br />

-Outputs<br />

4,096 4,096<br />

- Inputs, of which central<br />

256 64<br />

- Outputs, of which central<br />

256 64<br />

Configuration<br />

• Racks, max. 4 1<br />

• Modules per rack, max. 8 8<br />

Number of DP masters<br />

- integral 1 2<br />

- via CP 4 2<br />

Number of FMs and CPs that can<br />

be operated (recommendation)<br />

-FM 8 8<br />

- CP, point-to-point<br />

8 8<br />

- CP, LAN 10 10<br />

Time<br />

Clock<br />

- Hardware clock (realtime clock) Yes Yes<br />

- buffered<br />

Yes<br />

Yes<br />

- Deviation per day, max<br />

10 s 10 s<br />

Run-time meter<br />

- Quantity 4 4<br />

-Number 0 to 3 0 to 3<br />

- Range of values<br />

0 to 2^31 hours<br />

(when using<br />

SFC 101)<br />

0 to 2^31 hours<br />

(when using<br />

SFC 101)<br />

- Granularity<br />

1 hour 1 hour<br />

- retentive<br />

Yes; must be<br />

restarted on<br />

each complete<br />

restart<br />

Time synchronization<br />

- supported Yes Yes<br />

- on MPI, master<br />

Yes<br />

Yes<br />

- on MPI, slave<br />

Yes<br />

Yes<br />

- in AS, master<br />

Yes<br />

Yes<br />

- in AS, slave<br />

Yes<br />

Yes<br />

Yes; must be<br />

restarted on<br />

each complete<br />

restart<br />

S7 message functions<br />

• Number of stations that can log on<br />

for message functions, max.<br />

6ES7 317-<br />

2EJ10-0AB0<br />

32; depending<br />

on the connections<br />

configured<br />

for PG/OP<br />

and S7 basic<br />

communication<br />

6ES7 317-<br />

6TJ10-0AB0<br />

32; depending<br />

on the connections<br />

configured<br />

for PG/OP<br />

and S7 basic<br />

communication<br />

• Process diagnostic messages Yes Yes<br />

• simultaneously active Alarm-S 60 60<br />

blocks, max.<br />

Test and startup functions<br />

Status/modify<br />

- Variable Yes Yes<br />

- Variables<br />

Inputs, outputs,<br />

flags, DB,<br />

timers,<br />

counters<br />

Inputs, outputs,<br />

flags, DB,<br />

timers,<br />

counters<br />

- Number of variables, max.<br />

30 30<br />

- of which status variables, max.<br />

30 30<br />

- of which modify variables, max.<br />

14 14<br />

Forcing<br />

- Forcing Yes Yes<br />

- Forcing, variables<br />

Inputs, outputs Inputs, outputs<br />

- Forcing, number of variables,<br />

max.<br />

10 10<br />

• Status block Yes Yes<br />

• Single step Yes Yes<br />

• Number of breakpoints 2 2<br />

Diagnostic buffer<br />

- available Yes Yes<br />

- Number of inputs, max.<br />

100 100<br />

- adjustable<br />

No<br />

Communication functions<br />

• PG/OP communication Yes Yes<br />

• Routing Yes Yes<br />

Global data communication<br />

- supported Yes Yes<br />

- Size of GD packets, max.<br />

22 Byte 22 Byte<br />

S7 basic communication<br />

- supported Yes Yes<br />

S7 communication<br />

- supported Yes Yes<br />

S5 compatible communication<br />

- supported Yes; via CP and<br />

loadable FC<br />

Yes; via CP and<br />

loadable FC<br />

Standard communication<br />

- TCP/IP Yes<br />

- Number of connections, max. 8<br />

- Data length, max. 1.460 Byte<br />

Number of connections<br />

- overall 32 32<br />

- usable for PG communication<br />

31 31<br />

- usable for OP communication<br />

31 31<br />

- usable for S7 basic<br />

communication<br />

30 31<br />

4/28 Siemens ST 70 · 2005