SIMATIC S7-<strong>300</strong><br />

Central processing units<br />

CPU 312C to CPU 317F-2 DP<br />

■ Technical specifications (continued)<br />

6ES7 312-<br />

5BD01-0AB0<br />

CPU/blocks<br />

DB<br />

- Number, max. 511;<br />

DB 0 reserved<br />

- Size, max.<br />

6ES7 313-<br />

5BE01-0AB0<br />

511;<br />

DB 0 reserved<br />

6ES7 313-<br />

6BE01-0AB0<br />

511;<br />

DB 0 reserved<br />

6ES7 313-<br />

6CE01-0AB0<br />

511;<br />

DB 0 reserved<br />

6ES7 314-<br />

6BF01-0AB0<br />

511;<br />

DB 0 reserved<br />

6ES7 314-<br />

6CF01-0AB0<br />

511;<br />

DB 0 reserved<br />

16 KByte 16 KByte 16 KByte 16 KByte 16 KByte 16 KByte<br />

FB<br />

- Number, max. 512; from 512; from 512; from 512 512 512<br />

FB 0 to FB 511 FB 0 to FB 511 FB 0 to FB 511<br />

- Size, max. 16 KByte 16 KByte 16 KByte 16 KByte 16 KByte 16 KByte<br />

4<br />

FC<br />

- Number, max. 512; from 512; from 512; from 512 512 512<br />

FC 0 to FC 511 FC 0 to FC 511 FC 0 to FC 511<br />

- Size, max. 16 KByte 16 KByte 16 KByte 16 KByte 16 KByte 16 KByte<br />

OB<br />

- Number, max. See instruction<br />

list<br />

See instruction See instruction See instruction See instruction<br />

list<br />

list<br />

list<br />

list<br />

- Size, max. 16 KByte 16 KByte 16 KByte 16 KByte 16 KByte 16 KByte<br />

See instruction<br />

list<br />

Nesting depth<br />

- per priority class 8 8 8 8 8 8<br />

- additional levels within an<br />

error OB<br />

4 4 4 4 4 4<br />

CPU/processing times<br />

• for bit instruction, min. 0.2 µs 0.1 µs 0.1 µs 0.1 µs 0.1 µs 0.1 µs<br />

• for word instruction, min. 0.4 µs 0.2 µs 0.2 µs 0.2 µs 0.2 µs 0.2 µs<br />

• for integer math, min. 5 µs 2 µs 2 µs 2 µs 2 µs 2 µs<br />

• for floating-point math, min. 6 µs 3 µs 3 µs 3 µs 3 µs 3 µs<br />

Timers/counters and their<br />

retentive characteristics<br />

S7 counter<br />

-Number 128 256 256 256 256 256<br />

• of which retentive without battery<br />

- adjustable Yes Yes Yes Yes Yes Yes<br />

- lower limit 0 0 0 0 0 0<br />

- upper limit 128 256 256 256 256 256<br />

• Retentivity<br />

- adjustable Yes<br />

• Counting range<br />

- lower limit 0 0 0 0 0 0<br />

- upper limit 999 999 999 999 999 999<br />

IEC counter<br />

- available Yes Yes Yes Yes Yes Yes<br />

- Type SFB SFB SFB SFB SFB SFB<br />

S7 times<br />

-Number 128 256 256 256 256 256<br />

• Retentivity<br />

- adjustable Yes Yes Yes Yes Yes Yes<br />

- lower limit 0 0 0 0 0 0<br />

- upper limit 128 256 256 256 256 256<br />

- preset<br />

No retention No retention No retention No retention No retention No retention<br />

• Timing range<br />

- lower limit 10 ms 10 ms 10 ms 10 ms 10 ms 10 ms<br />

- upper limit 9,990 s 9,990 s 9,990 s 9,990 s 9,990 s 9,990 s<br />

IEC timer<br />

- available Yes Yes Yes Yes Yes Yes<br />

- Type SFB SFB SFB SFB SFB SFB<br />

Siemens ST 70 · 2005<br />

4/9