SIMATIC S7-400<br />

Central processing units<br />

CPU 416F-2<br />

5<br />

■ Technical specifications (continued)<br />

6ES7 416-2FK02-0AB0<br />

S5 compatible communication<br />

- supported Yes; via CP and FC AG_SEND<br />

and FC AG_RECV<br />

- User data per job, max. 8 KByte<br />

Standard communication<br />

- Supported Yes; via CP and loadable FB<br />

Number of connections<br />

- overall 64<br />

1st interface<br />

• Physical<br />

RS 485 / PROFIBUS<br />

• Isolated<br />

Yes<br />

Functionality<br />

-MPI<br />

Yes<br />

-DP master<br />

Yes<br />

- DP slave Yes<br />

MPI<br />

- Number of connections 44<br />

• Services<br />

- PG/OP communication Yes<br />

- Routing Yes<br />

- Global data communication Yes<br />

- S7 basic communication Yes<br />

- S7 communication Yes<br />

- Transmission rates, max. 12 Mbit/s<br />

DP master<br />

- Number of connections, max. 32<br />

• Services<br />

- PG/OP communication Yes<br />

- Routing Yes<br />

- S7 basic communication No<br />

- S7 communication Yes<br />

- Equidistance support Yes<br />

- Activate/deactivate DP slaves Yes<br />

- Direct data exchange<br />

Yes<br />

(lateral communication)<br />

- Transmission rates, max. 12 Mbit/s<br />

- Number of DP slaves, max. 32<br />

• User data per DP Slave<br />

- Inputs, max. 244 Byte<br />

-Outputs, max.<br />

244 Byte<br />

DP slave<br />

• Services<br />

- Routing Yes; with active interface<br />

- Status/modify Yes; with active interface<br />

- Programming Yes; with active interface<br />

- Transmission rates, max. 12 Mbit/s<br />

• Intermediate memory<br />

- Address areas, max. 32<br />

- User data per address area, 32 Byte<br />

max.<br />

- User data per address area, 32 Byte<br />

of which consistent, max.<br />

6ES7 416-2FK02-0AB0<br />

2nd interface<br />

• Physical<br />

RS 485 / PROFIBUS<br />

• Isolated<br />

Yes<br />

Functionality<br />

- DP master Yes<br />

- DP slave Yes<br />

DP master<br />

- Number of connections, max. 32<br />

• Services<br />

- PG/OP communication Yes<br />

- Routing Yes<br />

- S7 basic communication No<br />

- S7 communication Yes<br />

- Equidistance support Yes<br />

- Activate/deactivate DP slaves Yes<br />

- Direct data exchange<br />

Yes<br />

(lateral communication)<br />

- Transmission rates, max. 12 Mbit/s<br />

- Number of DP slaves, max. 125<br />

• Address area<br />

- Inputs, max. 8 KByte<br />

- Outputs, max. 8 KByte<br />

• User data per DP Slave<br />

- Inputs, max. 128 Byte<br />

- Outputs, max. 128 Byte<br />

DP slave<br />

• Services<br />

- Routing Yes; with active interface<br />

- Status/modify Yes; with active interface<br />

- Programming Yes; with active interface<br />

- Transmission rates, max. 12 Mbit/s<br />

• Intermediate memory<br />

- Inputs 244 Byte<br />

-Outputs<br />

244 Byte<br />

- Address areas, max. 32<br />

- User data per address area, 32 Byte<br />

max.<br />

- User data per address area, 32 Byte<br />

of which consistent, max.<br />

Clock synchronism<br />

• User data per clock synchronous 128 Byte<br />

slave, max.<br />

• Equidistance<br />

Yes<br />

• Shortest clock pulse<br />

5 ms; 2.5 ms without using<br />

SFCs 126 / 127<br />

CiR configuration in RUN<br />

• CiR synchronization time,<br />

100 ms<br />

base load<br />

• CiR synchronization time,<br />

120 µs<br />

time per I/O slave<br />

5/26 Siemens ST 70 · 2005