SIMATIC S7-400 Central processing units CPU 412-1 to CPU 417-4 ■ Technical specifications (continued) 6ES7 416-2XK04-0AB0 6ES7 416-3XL04-0AB0 6ES7 417-4XL04-0AB0 S5 compatible communication - supported Yes; via FC AG_SEND and AG_RECV, via a maximum of 10 CP 443-1 or 443-5 Yes; via FC AG_SEND and AG_RECV, via a maximum of 10 CP 443-1 or 443-5 Yes; via FC AG_SEND and AG_RECV, via a maximum of 10 CP 443-1 or 443-5 - User data per job, max. 8 KByte 8 KByte 8 KByte Standard communication (FMS) - Supported Yes; via CP and loadable FB Yes; via CP and loadable FB Yes; via CP and loadable FB Number of connections - overall 64 64 64 1st interface • Physical RS 485 / PROFIBUS RS 485 / PROFIBUS RS 485 / PROFIBUS • Isolated Yes Yes Yes Functionality -MPI Yes Yes Yes -DP master Yes Yes Yes - DP slave Yes Yes Yes MPI - Number of connections 44 44 44 • Services - PG/OP communication Yes Yes Yes - Routing Yes Yes Yes - Global data communication Yes Yes Yes - S7 basic communication Yes Yes Yes - S7 communication Yes Yes Yes - Transmission rates, max. 12 Mbit/s 12 Mbit/s 12 Mbit/s DP master - Number of connections, max. 32; if a diagnostic repeater is used in the chain, this reduces the number of connection resources in the chain by 1 32; if a diagnostic repeater is used in the chain, this reduces the number of connection resources in the chain by 1 • Services - PG/OP communication Yes Yes Yes - Routing Yes Yes Yes - S7 basic communication Yes Yes Yes - S7 communication Yes Yes Yes - Equidistance support Yes Yes Yes - Activate/deactivate DP slaves Yes Yes Yes - Direct data exchange Yes Yes Yes (lateral communication) - Transmission rates, max. 12 Mbit/s 12 Mbit/s 12 Mbit/s - Number of DP slaves, max. 32 32 32 • Address area - Inputs, max. 2 KByte 2 KByte 2 KByte -Outputs, max. 2 KByte 2 KByte 2 KByte • User data per DP Slave - Inputs, max. 244 Byte 244 Byte 244 Byte -Outputs, max. 244 Byte 244 Byte 244 Byte 32; if a diagnostic repeater is used in the chain, this reduces the number of connection resources in the chain by 1 5 Siemens ST 70 · 2005 5/15
SIMATIC S7-400 Central processing units CPU 412-1 to CPU 417-4 ■ Technical specifications (continued) 6ES7 416-2XK04-0AB0 6ES7 416-3XL04-0AB0 6ES7 417-4XL04-0AB0 DP slave • Services - Routing Yes Yes Yes - Status/modify Yes Yes Yes - Programming Yes Yes Yes - Transmission rates, max. 12 Mbit/s 12 Mbit/s 12 Mbit/s 5 • Intermediate memory - Inputs 244 Byte 244 Byte 244 Byte -Outputs 244 Byte 244 Byte 244 Byte - Address areas, max. 32 32 32 - User data per address area, 32 Byte 32 Byte 32 Byte max. - User data per address area, of 32 Byte 32 Byte 32 Byte which consistent, max. 2nd interface • Physical RS 485 / PROFIBUS RS 485 / PROFIBUS RS 485 / PROFIBUS • Isolated Yes Yes Yes Functionality -DP master Yes Yes Yes - DP slave Yes Yes Yes DP master - Number of connections, max. 32; if a diagnostic repeater is used in the chain, this reduces the number of connection resources in the chain by 1 32; if a diagnostic repeater is used in the chain, this reduces the number of connection resources in the chain by 1 • Services - PG/OP communication Yes Yes Yes - Routing Yes Yes Yes - S7 basic communication Yes Yes Yes - S7 communication Yes Yes Yes - Equidistance support Yes Yes Yes - Activate/deactivate DP slaves Yes Yes Yes - Direct data exchange Yes Yes Yes (lateral communication) - Transmission rates, max. 12 Mbit/s 12 Mbit/s 12 Mbit/s - Number of DP slaves, max. 125 125 125 • Address area - Inputs, max. 8 KByte 8 KByte 8 KByte -Outputs, max. 8 KByte 8 KByte 8 KByte • User data per DP Slave - Inputs, max. 244 Byte 244 Byte 244 Byte -Outputs, max. 244 Byte 244 Byte 244 Byte DP slave • Services - Routing Yes Yes Yes - Status/modify Yes Yes Yes - Programming Yes Yes Yes - Transmission rates, max. 12 Mbit/s 12 Mbit/s 12 Mbit/s • Intermediate memory - Inputs 244 Byte 244 Byte 244 Byte -Outputs 244 Byte 244 Byte 244 Byte - Address areas, max. 32 32 32 - User data per address area, 32 Byte 32 Byte 32 Byte max. - User data per address area, of which consistent, max. 32 Byte 32 Byte 32 Byte 32; if a diagnostic repeater is used in the chain, this reduces the number of connection resources in the chain by 1 5/16 Siemens ST 70 · 2005
- Page 127 and 128: SIMATIC S7-300 Communication CP 340
- Page 129 and 130: SIMATIC S7-300 Communication SIPLUS
- Page 131 and 132: SIMATIC S7-300 Communication CP 341
- Page 133 and 134: SIMATIC S7-300 Communication CP 343
- Page 135 and 136: 4 SIMATIC S7-300 Communication CP 3
- Page 137 and 138: 4 SIMATIC S7-300 Communication CP 3
- Page 139 and 140: SIMATIC S7-300 Communication CP 343
- Page 141 and 142: SIMATIC S7-300 Communication CP 343
- Page 143 and 144: 4 SIMATIC S7-300 Communication CP 3
- Page 145 and 146: SIMATIC S7-300 Communication CP 343
- Page 147 and 148: 4 SIMATIC S7-300 Communication CP 3
- Page 149 and 150: SIMATIC S7-300 Connection methods F
- Page 151 and 152: 4 SIMATIC S7-300 Connection methods
- Page 153 and 154: 4 SIMATIC S7-300 Connection methods
- Page 155 and 156: SIMATIC S7-300 Interface modules IM
- Page 157 and 158: SIMATIC S7-300 Power supplies Power
- Page 159 and 160: SIMATIC S7-300 Power supplies Power
- Page 161 and 162: 4 SIMATIC S7-300 Accessories DIN ra
- Page 163 and 164: SIMATIC S7-300 4 4/170 Siemens ST 7
- Page 165 and 166: SIMATIC S7-400 Introduction SIMATIC
- Page 167 and 168: SIMATIC S7-400 Central processing u
- Page 169 and 170: SIMATIC S7-400 Central processing u
- Page 171 and 172: SIMATIC S7-400 Central processing u
- Page 173 and 174: SIMATIC S7-400 Central processing u
- Page 175 and 176: SIMATIC S7-400 Central processing u
- Page 177: SIMATIC S7-400 Central processing u
- Page 181 and 182: SIMATIC S7-400 Central processing u
- Page 183 and 184: SIMATIC S7-400 Central processing u
- Page 185 and 186: SIMATIC S7-400 Central processing u
- Page 187 and 188: SIMATIC S7-400 Central processing u
- Page 189 and 190: SIMATIC S7-400 Central processing u
- Page 191 and 192: SIMATIC S7-400 Central processing u
- Page 193 and 194: SIMATIC S7-400 Central processing u
- Page 195 and 196: SIMATIC S7-400 Digital modules Digi
- Page 197 and 198: SIMATIC S7-400 Digital modules Digi
- Page 199 and 200: SIMATIC S7-400 Digital modules Digi
- Page 201 and 202: SIMATIC S7-400 Analog modules Analo
- Page 203 and 204: SIMATIC S7-400 Analog modules Analo
- Page 205 and 206: SIMATIC S7-400 Analog modules Analo
- Page 207 and 208: SIMATIC S7-400 Analog modules Analo
- Page 209 and 210: SIMATIC S7-400 Function modules FM
- Page 211 and 212: 5 SIMATIC S7-400 Function modules F
- Page 213 and 214: SIMATIC S7-400 Function modules Cam
- Page 215 and 216: SIMATIC S7-400 Function modules FM
- Page 217 and 218: SIMATIC S7-400 Function modules FM
- Page 219 and 220: SIMATIC S7-400 Function modules FM
- Page 221 and 222: SIMATIC S7-400 Function modules FM
- Page 223 and 224: SIMATIC S7-400 Function modules EXM
- Page 225 and 226: SIMATIC S7-400 Function modules EXM
- Page 227 and 228: SIMATIC S7-400 Function modules Acc
SIMATIC S7-400<br />
Central processing units<br />
CPU 412-1 to CPU 417-4<br />
■ Technical specifications (continued)<br />
6ES7 416-2XK04-0AB0 6ES7 416-3XL04-0AB0 6ES7 417-4XL04-0AB0<br />
S5 compatible communication<br />
- supported Yes; via FC AG_SEND and<br />
AG_RECV, via a maximum<br />
of 10 CP 443-1 or 443-5<br />
Yes; via FC AG_SEND and<br />
AG_RECV, via a maximum<br />
of 10 CP 443-1 or 443-5<br />
Yes; via FC AG_SEND and<br />
AG_RECV, via a maximum<br />
of 10 CP 443-1 or 443-5<br />
- User data per job, max. 8 KByte 8 KByte 8 KByte<br />
Standard communication (FMS)<br />
- Supported Yes; via CP and loadable FB Yes; via CP and loadable FB Yes; via CP and loadable FB<br />
Number of connections<br />
- overall 64 64 64<br />
1st interface<br />
• Physical RS 485 / PROFIBUS RS 485 / PROFIBUS RS 485 / PROFIBUS<br />
• Isolated Yes Yes Yes<br />
Functionality<br />
-MPI Yes Yes Yes<br />
-DP master Yes Yes Yes<br />
- DP slave Yes Yes Yes<br />
MPI<br />
- Number of connections 44 44 44<br />
• Services<br />
- PG/OP communication Yes Yes Yes<br />
- Routing Yes Yes Yes<br />
- Global data communication Yes Yes Yes<br />
- S7 basic communication Yes Yes Yes<br />
- S7 communication Yes Yes Yes<br />
- Transmission rates, max. 12 Mbit/s 12 Mbit/s 12 Mbit/s<br />
DP master<br />
- Number of connections, max. 32; if a diagnostic repeater is<br />
used in the chain, this reduces<br />
the number of connection<br />
resources in the chain by 1<br />
32; if a diagnostic repeater is<br />
used in the chain, this reduces<br />
the number of connection<br />
resources in the chain by 1<br />
• Services<br />
- PG/OP communication Yes Yes Yes<br />
- Routing Yes Yes Yes<br />
- S7 basic communication Yes Yes Yes<br />
- S7 communication Yes Yes Yes<br />
- Equidistance support Yes Yes Yes<br />
- Activate/deactivate DP slaves Yes Yes Yes<br />
- Direct data exchange<br />
Yes Yes Yes<br />
(lateral communication)<br />
- Transmission rates, max. 12 Mbit/s 12 Mbit/s 12 Mbit/s<br />
- Number of DP slaves, max. 32 32 32<br />
• Address area<br />
- Inputs, max. 2 KByte 2 KByte 2 KByte<br />
-Outputs, max. 2 KByte 2 KByte 2 KByte<br />
• User data per DP Slave<br />
- Inputs, max. 244 Byte 244 Byte 244 Byte<br />
-Outputs, max. 244 Byte 244 Byte 244 Byte<br />
32; if a diagnostic repeater is<br />
used in the chain, this reduces<br />
the number of connection<br />
resources in the chain by 1<br />