SIMATIC S7-400<br />
Central processing units<br />
CPU 412-1 to CPU 417-4<br />
■ Technical specifications (continued)<br />
6ES7 416-2XK04-0AB0 6ES7 416-3XL04-0AB0 6ES7 417-4XL04-0AB0<br />
5<br />
CPU/blocks<br />
DB<br />
- Number, max. 4,095; DB 0 reserved 4,095; DB 0 reserved 8,192; DB 0 reserved<br />
- Size, max. 64 KByte 64 KByte 64 KByte<br />
FB<br />
- Number, max. 2,048 2,048 6,144<br />
- Size, max. 64 KByte 64 KByte 64 KByte<br />
FC<br />
- Number, max. 2,048 2,048 6,144<br />
- Size, max. 64 KByte 64 KByte 64 KByte<br />
OB<br />
- Number, max. See instruction list See instruction list See instruction list<br />
- Size, max. 64 KByte 64 KByte 64 KByte<br />
Nesting depth<br />
- per priority class 24 24 24<br />
- additional levels within<br />
2 2 2<br />
an error OB<br />
CPU/processing times<br />
• for bit instruction, min. 0.04 µs 0.04 µs 0.03 µs<br />
• for word instruction, min. 0.04 µs 0.04 µs 0.03 µs<br />
• for integer math, min. 0.04 µs 0.04 µs 0.03 µs<br />
• for floating-point math, min. 0.12 µs 0.12 µs 0.09 µs<br />
Timers/counters and their<br />
retentive characteristics<br />
S7 counter<br />
-Number 2,048 2,048 2,048<br />
• Retentivity<br />
- adjustable Yes Yes Yes<br />
- lower limit 0 0 0<br />
- upper limit 2,047 2,047 2,047<br />
- preset from Z 0 to Z 7 from Z 0 to Z 7 from Z 0 to Z 7<br />
• Counting range<br />
- lower limit 0 0 0<br />
- upper limit 999 999 999<br />
IEC counter<br />
- available Yes Yes Yes<br />
- Type SFB, unlimited quantity<br />
(only limited by working memory)<br />
SFB, unlimited quantity<br />
(only limited by working memory)<br />
SFB, unlimited quantity<br />
(only limited by working memory)<br />
S7 times<br />
-Number 2,048 2,048 2,048<br />
• Retentivity<br />
- adjustable Yes Yes Yes<br />
- lower limit 0 0 0<br />
- upper limit 2,047 2,047 2,047<br />
- preset no timers retentive no timers retentive no timers retentive<br />
• Timing range<br />
- lower limit 10 ms 10 ms 10 ms<br />
- upper limit 9,990 s 9,990 s 9,990 s<br />
IEC timer<br />
- available Yes Yes Yes<br />
- Type SFB, unlimited quantity<br />
(only limited by working memory)<br />
Data areas and their<br />
retentive characteristics<br />
• Retentive data area as a whole<br />
total working and load memory<br />
(with backup battery)<br />
SFB, unlimited quantity<br />
(only limited by working memory)<br />
total working and load memory<br />
(with backup battery)<br />
SFB, unlimited quantity<br />
(only limited by working memory)<br />
total working and load memory<br />
(with backup battery)<br />
Flags<br />
-Number 16 KByte 16 KByte 16 KByte<br />
- adjustable retentivity Yes; MB 0 to MB 16383 Yes; MB 0 to MB 16383 Yes; MB 0 to MB 16383<br />
- Number of clock memories 8; (1 memory byte) 8; (1 memory byte) 8; 1 memory byte)<br />
5/12 Siemens ST 70 · 2005