SIMATIC S7-400<br />

Central processing units<br />

CPU 412-1 to CPU 417-4<br />

■ Technical specifications (continued)<br />

6ES7 412-1XF04-0AB0 6ES7 412-2XG04-0AB0 6ES7 414-2XG04-0AB0 6ES7 414-3XJ04-0AB0<br />

Digital channels<br />

- Inputs 32,768 32,768 65,536 65,536<br />

-Outputs 32,768 32,768 65,536 65,536<br />

- Inputs, of which central 32,768 32,768 65,536 65,536<br />

- Outputs, of which central 32,768 32,768 65,536 65,536<br />

Analog channels<br />

- Inputs 2,048 2,048 4,096 4,096<br />

-Outputs 2,048 2,048 4,096 4,096<br />

- Inputs, of which central 2,048 2,048 4,096 4,096<br />

- Outputs, of which central 2,048 2,048 4,096 4,096<br />

Configuration<br />

• connectable OP<br />

15 without message<br />

processing, 8 with<br />

message processing<br />

15 without message<br />

processing, 8 with<br />

message processing<br />

31 without event<br />

processing, 8 with<br />

event processing<br />

31 without event<br />

processing, 8 with<br />

event processing<br />

• Central units, max. 1 1 1 1<br />

• Expansion units, max. 21 21 21 21<br />

• Multi-computing<br />

Yes; maximum 4 CPUs<br />

(with UR1 or UR2)<br />

Yes; max. 4 CPUs<br />

(with UR1 or UR2)<br />

Yes; max. 4 CPUs<br />

(with UR1 or UR2)<br />

Yes; max. 4 CPUs<br />

(with UR1 or UR2)<br />

IM<br />

- Number of pluggable IMs 6 6 6 6<br />

(overall), max.<br />

- Number of pluggable IM 460s, 6 6 6 6<br />

max.<br />

- Number of pluggable IM 463s, 4; IM 463-2 4; IM 463-2 4; IM 463-2 4; IM 463-2<br />

max.<br />

Number of DP masters<br />

- integral 1 2 2 2<br />

- via IM 467 4 4 4 4<br />

- via CP 10; CP 443-5 Ext. 10; CP 443-5 Ext. 10; CP 443-5 Ext. 10; CP 443-5 Ext.<br />

- Mixed mode of IM + CP<br />

permitted<br />

No; IM467 cannot be<br />

used externally together<br />

with CP443-5!<br />

No; IM467 cannot be<br />

used externally together<br />

with CP443-5!<br />

No; IM467 cannot be<br />

used externally together<br />

with CP443-5!<br />

No; IM467 cannot be<br />

used externally together<br />

with CP443-5<br />

- via interface module 0 0 0 1; IF 964-DP<br />

- No. pluggable S5 modules<br />

(via adapter casing in centr. unit)<br />

max<br />

6 6 6 6<br />

Number of FMs and CPs that can<br />

be operated (recommendation)<br />

-FM<br />

limited by the number of<br />

slots and by the number<br />

of connections<br />

- CP, point-to-point CP 440: limited by the<br />

number of slots<br />

CP 441: limited by the<br />

number of connections<br />

- CP, LAN limited by the number of<br />

slots and by the number<br />

of connections<br />

- PROFIBUS and Ether<strong>net</strong> CPs 14; incl. CP 443-5<br />

Extended and IM 467<br />

limited by the number of<br />

slots and by the number<br />

of connections<br />

CP 440: limited by the<br />

number of slots<br />

CP 441: limited by the<br />

number of connections<br />

limited by the number of<br />

slots and by the number<br />

of connections<br />

14; incl. CP443-5 ext.<br />

and IM467<br />

limited by the number of<br />

slots and by the number<br />

of connections<br />

CP 440: limited by the<br />

number of slots<br />

CP 441: limited by the<br />

number of connections<br />

limited by the number of<br />

slots and by the number<br />

of connections<br />

14; incl. CP 443-5 ext.<br />

and IM 467<br />

limited by the number of<br />

slots and by the number<br />

of connections<br />

CP 440: limited by the<br />

number of slots<br />

CP 441: limited by the<br />

number of connections<br />

limited by the number of<br />

slots and by the number<br />

of connections<br />

14; incl. CP 443-5 Ext.<br />

and IM 467<br />

Time<br />

Clock<br />

- Hardware clock (realtime clock) Yes Yes Yes Yes<br />

- buffered Yes Yes Yes Yes<br />

- Triggering 1 ms 1 ms 1 ms 1 ms<br />

Run-time meter<br />

- Quantity 8 8 8 8<br />

Time synchronization<br />

- supported Yes Yes Yes Yes<br />

- on MPI, master Yes Yes Yes Yes<br />

- on MPI, slave Yes Yes Yes Yes<br />

- on DP, master Yes Yes Yes Yes<br />

- on DP, slave Yes Yes Yes Yes<br />

- in AS, master Yes Yes Yes Yes<br />

- in AS, slave Yes Yes Yes Yes<br />

- on IF 964 DP Yes; as Master or Slave<br />

5<br />

Siemens ST 70 · 2005<br />

5/7