SIMATIC S7-400<br />

Central processing units<br />

CPU 412-1 to CPU 417-4<br />

■ Technical specifications (continued)<br />

Timers/counters and their<br />

retentive characteristics<br />

6ES7 412-1XF04-0AB0 6ES7 412-2XG04-0AB0 6ES7 414-2XG04-0AB0 6ES7 414-3XJ04-0AB0<br />

S7 counter<br />

-Number 2,048 2,048 2,048 2,048<br />

5<br />

• Retentivity<br />

- adjustable Yes Yes Yes Yes<br />

- lower limit 0 0 0 0<br />

- upper limit 2,047 2,047 2,047 2,047<br />

- preset Z 0 to Z 7 Z 0 to Z 7 from Z 0 to Z 7 from Z 0 to Z 7<br />

• Counting range<br />

- lower limit 0 0 0 0<br />

- upper limit 999 999 999 999<br />

IEC counter<br />

- available Yes Yes Yes Yes<br />

- Type SFB, unlimited quantity<br />

(only limited by working<br />

memory)<br />

SFB, unlimited quantity<br />

(only limited by working<br />

memory)<br />

SFB, unlimited quantity<br />

(only limited by working<br />

memory)<br />

SFB, unlimited quantity<br />

(only limited by working<br />

memory)<br />

S7 times<br />

-Number 2,048 2,048 2,048 2,048<br />

• Retentivity<br />

- adjustable Yes Yes Yes Yes<br />

- lower limit 0 0 0 0<br />

- upper limit 2,047 2,047 2,047 2,047<br />

- preset no timers retentive no timers retentive no timers retentive no timers retentive<br />

• Timing range<br />

- lower limit 10 ms 10 ms 10 ms 10 ms<br />

- upper limit 9,990 s 9,990 s 9,990 s 9,990 s<br />

IEC timer<br />

- available Yes Yes Yes Yes<br />

- Type SFB, unlimited quantity<br />

(only limited by working<br />

memory)<br />

Data areas and their retentive<br />

characteristics<br />

• Retentive data area as a whole<br />

total working and<br />

load memory<br />

(with backup battery)<br />

SFB, unlimited quantity<br />

(only limited by working<br />

memory)<br />

total working and<br />

load memory<br />

(with backup battery)<br />

SFB, unlimited quantity<br />

(only limited by working<br />

memory)<br />

total working and<br />

load memory<br />

(with backup battery)<br />

Flags<br />

-Number 4 KByte 4 KByte 8 KByte 8 KByte<br />

- adjustable retentivity Yes; from MB 0 to<br />

MB 4095<br />

Yes; from MB 0 to<br />

MB 4095<br />

Yes; from MB 0 to<br />

MB 8191<br />

SFB, unlimited quantity<br />

(only limited by working<br />

memory)<br />

total working and<br />

load memory<br />

(with backup battery)<br />

Yes; from MB 0 to<br />

MB 8191<br />

- Number of clock memories 8; (1 memory byte) 8; (1 memory byte) 8; (1 memory byte) 8; (1 memory byte)<br />

Address area<br />

I/O address area<br />

- Inputs 4 KByte 4 KByte 8 KByte 8 KByte<br />

-Outputs 4 KByte 4 KByte 8 KByte 8 KByte<br />

• of which distributed<br />

- MPI/DP interface, inputs 2 KByte 2 KByte 2 KByte 2 KByte<br />

- MPI/DP interface, outputs 2 KByte 2 KByte 2 KByte 2 KByte<br />

- DP interface, inputs 4 KByte 6 KByte 6 KByte<br />

- DP interface, outputs 4 KByte 6 KByte 6 KByte<br />

Process image<br />

- Inputs, adjustable 4 KByte 4 KByte 8 KByte 8 KByte<br />

- Outputs, adjustable 4 KByte 4 KByte 8 KByte 8 KByte<br />

- Inputs, preset 128 Byte 128 Byte 256 Byte 256 Byte<br />

- Outputs, preset 128 Byte 128 Byte 256 Byte 256 Byte<br />

- Number of component process 15 15 15 15<br />

images, max.<br />

- Access to consistent data in the Yes Yes Yes Yes<br />

process image<br />

- Consistent data, max. 244 Byte 244 Byte 244 Byte 244 Byte<br />

5/6 Siemens ST 70 · 2005