SIMATIC S7-<strong>300</strong><br />

Communication<br />

CP 343-5<br />

■ Overview<br />

4<br />

Master connection of SIMATIC S7-<strong>300</strong> and SIMATIC C7 to<br />

PROFIBUS up to 12 Mbit/s (incl. 45.45 Kbit/s)<br />

• Communication services:<br />

- PG/OP communication<br />

- S7 communication<br />

- S5-compatible communication (SEND/RECEIVE)<br />

- PROFIBUS FMS<br />

• Simple configuration and programming using PROFIBUS<br />

• Easily integrated into the S7-<strong>300</strong> system<br />

• PG communication between <strong>net</strong>works through S7 routing<br />

• Module changeover without PG<br />

■ Technical specifications<br />

Data transmission rate<br />

9.6 kbit/s to 12 Mbit/s<br />

Interfaces<br />

• Connection to PROFIBUS 9-pin Sub-D socket (RS 485)<br />

• Connection to supply voltage 4-pin terminal block<br />

Power supply<br />

24 V DC<br />

Current consumption<br />

• From backplane bus<br />

150 mA<br />

• from 24 V<br />

250 mA<br />

Power loss<br />

6.75 W<br />

Perm. ambient conditions<br />

• Operating temperature 0 °C to +60 °C<br />

• Transport/storage temperature -40 °C to +70 °C<br />

• Relative humidity<br />

Max. 95% at +25°C<br />

Construction<br />

• Module format<br />

Compact module<br />

• Dimensions (WxHxD) in mm 40 x 125 x 120<br />

• Weight<br />

Approx. <strong>300</strong> g<br />

Number of CPs per S7-<strong>300</strong> 4<br />

Performance data for S7 communication<br />

• Number of connections that can<br />

be used<br />

Performance data for S5-compatible<br />

interface (SEND/RECEIVE)<br />

• Number of connections that can<br />

be used<br />

• Useful data / connection<br />

max. 16 1)<br />

max. 16<br />

Performance data<br />

for FMS function<br />

• Number of connections that can Max. 16<br />

be used<br />

Variable length for READ<br />

237 bytes<br />

Variable length for<br />

233 bytes<br />

WRITE and REPORT<br />

Configurable server variables 256<br />

Variables that can be loaded from 256<br />

partners<br />

Multi-protocol operation<br />

• Number of connections<br />

Max. 48<br />

that can be used<br />

max. 240 bytes<br />

(SEND and RECEIVE)<br />

1) Dependent on the CPU used<br />

4/146 Siemens ST 70 · 2005