Special Devices (P700 = 5)<br />

Point of Measurement<br />

The transducer must be above the maximum head P704 by at least the near<br />

blanking distance P107.<br />

In the case of a Palmer Bowlus flume the point of head measurement<br />

should be half the value of Dim “A” P710 upstream of the device.<br />

For an H-Flume the head measurement is taken at a point downstream<br />

from the flume entrance as detailed in the table below:<br />

Flume size Point of Measurement<br />

Dim. “A” P710<br />

cm Feet cm inches<br />

15.25 0.5 4.7 1.88<br />

23.00 0.75 6.7 2.69<br />

30.05 1.0 9.1 3.63<br />

45.70 1.5 13.5 5.38<br />

61.00 2.0 17.9 7.19<br />

76.20 2.5 22.5 9.00<br />

91.45 3.0 27.2 10.88<br />

137.15 4.5 40.5 16.19<br />