Trapezoidal<br />

Page 72<br />

If the flow calculation is to be absolute P702 = 1 the flow will be calculated<br />

using the formula: q = vh (b + mh)<br />

Where: q = flowrate<br />

v = velocity<br />

h = head<br />

b = base width (Dim“B”) P711<br />

m = side slope calculated from<br />

m = (B -b)/d where B = channel top width (Dim “A”) P710,<br />

b = base width (Dim “B”) P711<br />

d = depth of channel (Dim “C”) P712