- Page 1: FlowCERT INSTRUCTION MANUAL
- Page 5 and 6: Contents Chapter 1 Start Here…...
- Page 7: Common Parameters..................
- Page 12 and 13: About the FlowCERT The FlowCERT ope
- Page 14 and 15: Page 4 The FlowCERT can be programm
- Page 16 and 17: Digital output Volt free contacts,
- Page 18 and 19: Location All electronic products ar
- Page 20 and 21: The full dimensions of the enclosur
- Page 22 and 23: Page 12 Wire the transducer to the
- Page 24 and 25: Important Information Before applyi
- Page 26 and 27: Page 16 This page left blank intent
- Page 28 and 29: • The DUET should be installed su
- Page 30 and 31: Fitting Options Using the fixings s
- Page 32 and 33: Technical data Sensor Dimensions Pa
- Page 34 and 35: Installation Limitation of Performa
- Page 36 and 37: Distance from valves and slide gate
- Page 38 and 39: Flumes and Channels For installatio
- Page 40 and 41: Operation and parameters Quick Star
- Page 42 and 43: Recovery of Speedy communications i
- Page 44 and 45: 3) Auxiliary Display, scrolling twe
- Page 46 and 47: Hot Keys There are five hot keys on
- Page 48 and 49: There are two means of editing para
- Page 50 and 51: Test Mode Test mode is used to simu
- Page 52 and 53: Other commands you can use are: /LE
- Page 54 and 55: Page 44 This page left blank intent
- Page 56 and 57: Choose Your Application There are s
- Page 58 and 59:
Quick Setup Menu Quick Setup PMD Ty
- Page 60 and 61:
Parameter Default Description P823
- Page 62 and 63:
Exponential Devices (P700 = 1) If t
- Page 64 and 65:
For a Leopald Lagco flume the head
- Page 66 and 67:
Exponent Type Formula Exponent K Fa
- Page 68 and 69:
To program the FlowCERT for Example
- Page 70 and 71:
Calculations Rectangular Flume ABSO
- Page 72 and 73:
Example 2 BS3680 U-Throated Flume I
- Page 74 and 75:
BS3680 Weirs (P700 = 3) Point of Me
- Page 76 and 77:
Example 3 BS3680 Rectangular Weir P
- Page 78 and 79:
BS3680 Rectangular Broad Crested We
- Page 80 and 81:
Velocity Area (P700 = 4) The calcul
- Page 82 and 83:
Trapezoidal Page 72 If the flow cal
- Page 84 and 85:
Special Devices (P700 = 5) Point of
- Page 86 and 87:
RATIOMETRIC V-Notch Angle Weir (Non
- Page 88 and 89:
Application Menu Operation Distance
- Page 90 and 91:
Data Logs Menu Totaliser Audit P460
- Page 92 and 93:
Display Menu Options Fail Safe Auxi
- Page 94 and 95:
Compensation Offset Temperature Vel
- Page 96 and 97:
System Menu Passcode Backup System
- Page 98 and 99:
Test Menu Simulation Hardware P980
- Page 100 and 101:
Dimensions P104 Measurement Units T
- Page 102 and 103:
mA Input The 4-20 mA (Auxiliary) in
- Page 104 and 105:
P210, P220, P230, P240, P250 - Rela
- Page 106 and 107:
The third parameter for each relay
- Page 108 and 109:
Important Information Setpoints are
- Page 110 and 111:
Page 100 Pump Duty Description 5= D
- Page 112 and 113:
The fourth parameter and the fifth
- Page 114 and 115:
The third parameter for each relay
- Page 116 and 117:
Important Information When using a
- Page 118 and 119:
Data Log Parameters The data log pa
- Page 120 and 121:
OCM Parameters PMD Setup P700 Prima
- Page 122 and 123:
P702 Calculation Select the require
- Page 124 and 125:
Dimensions P710 Dimension A This pa
- Page 126 and 127:
P714 Roughness Coefficient (Ks) Whe
- Page 128 and 129:
Calculations The following paramete
- Page 130 and 131:
When P130 Device Mode = 2 Speedy, u
- Page 132 and 133:
P691 High level trigger This parame
- Page 134 and 135:
P804 Display Conversion The reading
- Page 136 and 137:
P814 Miscellaneous Messages This pa
- Page 138 and 139:
Bargraph P829 Bargraph By default t
- Page 140 and 141:
Limits P836 mA 1 Low Limit This par
- Page 142 and 143:
Setpoint By default the mA Output w
- Page 144 and 145:
Temperature P852 Temperature Source
- Page 146 and 147:
P876 Rate Distance This parameter i
- Page 148 and 149:
System Parameters Passcode P921 Ena
- Page 150 and 151:
LED Colour Each relay has an associ
- Page 152 and 153:
Daylight Saving Time Important Info
- Page 154 and 155:
P977 End Day Use this parameter to
- Page 156 and 157:
Device Comm. RS232 Set Up P061 Comm
- Page 158 and 159:
Example Telephone number to be dial
- Page 160 and 161:
Hardware P990 Self Test If you ente
- Page 162 and 163:
Page 152 This page left blank inten
- Page 164 and 165:
Page 154 This page left blank inten
- Page 166 and 167:
RELAYS Relay 1 Parameter Details En
- Page 168 and 169:
Totaliser Audits Parameter Details
- Page 170 and 171:
Breakpoints Parameter Details Enter
- Page 172 and 173:
Velocity (current) Parameter Detail
- Page 174 and 175:
Limits Parameter Details Entered Va
- Page 176 and 177:
Rate Parameter Details Entered Valu
- Page 178: