RATIOMETRIC<br />

BS3680 Rectangular Weir<br />

If the flow calculation is to be ratiometric P702 = 2 the flow will be<br />

calculated using the formula: q= q cal C e /C ecal (h e /h ecal ) 1.5<br />

Where: q = flowrate<br />

q cal = flowrate at maximum head P705<br />

Ce = discharge coefficient calculated by <strong>FlowCERT</strong> P723<br />

Ce cal = discharge coefficient at maximum head<br />

he = effective head<br />

= effective head at maximum head<br />

he cal<br />