Example 2 BS3680 U-Throated Flume<br />

In this example it is required to calculate to BS3680 the flow through a U-<br />

Throated Flume without any hump. Absolute calculation will be used, and<br />

there is a requirement for an alarm to indicate a low flow condition which<br />

will be set to relay 1. The flow rate is to be displayed in cubic meters/hour<br />

and the totaliser is also to record the flow in cubic metres, the resettable<br />

totaliser is to be displayed during RUN.<br />

The distance from the face of the lower transducer (DUET) to zero flow<br />

(P105) is 1 metre and max head (P704) is 0.4 metres, maximum<br />

flow(P705)<br />

The dimensions of the flume are as follows:<br />

Approach Channel diameter (Dim “A”) P710 = 0.7 m<br />

Throat diameter (Dim “B”) P711<br />

= 0.5 m<br />

Throat length (Dim “C”) P712<br />

= 1.0 m<br />

Page 62