Exponential Devices (P700 = 1)<br />

If the primary measuring device is a simple exponential device then an<br />

exponent value is required. The <strong>FlowCERT</strong> will automatically enter the<br />

exponent value for the device chosen as detailed in the table below.<br />

Exponent Type<br />

Suppressed Rectangular<br />

Weir<br />

(Without End Contractions)<br />

Exponent P717<br />

1.50<br />

Automatically<br />

set<br />

Cipolletti (Trapezoidal) Weir 1.50<br />

Automatically<br />

set<br />

Venturi Flume 1.50<br />

Automatically<br />

set<br />

Parshall Flume<br />

Leopold Lagco Flume 1.55<br />

Automatically<br />

calculated<br />

according to<br />

throat size<br />

V-Notch Weir 2.50<br />

Other As per manufacturer Value to be set<br />

as required via<br />

P717<br />

Contracted Rectangular Weir<br />

(With End Contractions)<br />

1.50<br />