Positioning of the Speedy sensor<br />

The required mounting distances between any hydraulic disturbance and the<br />

installation point are as follows:<br />

Change of profile<br />

h < 2.5% of Diameter, L>min. 3 x Diameter<br />

h > 2.5% of Diameter, L = distance to where standing wave does not exist<br />

anymore.<br />

Curves and Bends<br />

for v < 1m/s (3fps):<br />

a < 15° L> min. 3 x Diameter<br />

a < 45° L> min. 10 x Diameter<br />

a < 90° L > min. 20 x DN<br />

for v > 1m/s (3fps):<br />

a > 15° L = distance until the surface of the water reaches laminar flow<br />