• The DUET should be installed such that the bottom transducer is at<br />

least 300mm (12") above the maximum head.<br />

• Maximum accuracy will be achieved when the distance from the<br />

DUET’s lower transducers face to the target is within 1.5metres (4.9').<br />

• Ensure the DUET is installed upright and level, perpendicular to the<br />

target surface and is fixed securely.<br />

• The ‘U’ bolts can be fixed horizontally or vertically in the fixing plate<br />

dependant on the beam it is being attached to.<br />

Dimensions<br />

220.2mm (8.67")<br />

624.0mm (24.57")<br />

205.4mm (8.09")<br />