Digital output<br />

Volt free contacts, number and rating<br />

Display<br />

Full Duplex RS232<br />

5 form "C" (SPDT) rated at 5A at<br />

115V/240V AC<br />

6 digits plus 12 character text, plus<br />

bargraph with direction indicators,<br />

remote communicator identifier, and<br />

program/run/test mode indicators<br />

Analogue Input<br />

0-20 or 4-20 mA Isolated (floating) input (to 150V)<br />

4-20mA or 0-20 mA source or sink,<br />

open circuit voltage (source) 33V,<br />

22V at 4mA, 14V at 20mA<br />

(user programmable and adjustable)<br />

0.1% resolution<br />

Velocity input<br />

Speedy velocity sensor<br />

(for full specification of<br />

Speedy refer to<br />

Chapter 3 Speedy Velocity Sensor)<br />

Programming<br />

On-board programming<br />

PC programming<br />

Programming security<br />

Programmed data integrity<br />

Supply<br />

Power supply<br />

Fuses<br />

via RS 485 digital communications<br />

interface<br />

By integral keypad<br />

via RS232<br />

Via passcode (user selectable and<br />

adjustable)<br />

Via non-volatile RAM, plus backup<br />

115V ac + 5% / -10% 50/60 Hz,<br />

230V ac + 5% / -10% 50/60 Hz,<br />

dc 22 - 28V<br />

10W maximum power (typically 6W)<br />

100 mA at 210-240 VAC<br />

200 mA at 105-120 VAC<br />

Pulsar Process Measurement Limited operates a policy of constant development and<br />

improvement and reserve the right to amend technical details as necessary.<br />