Calculations<br />

The following parameters P720 to P725 are values calculated by the unit,<br />

dependent on application, and are “Read Only”, therefore have no default<br />

values.<br />

P720 Area<br />

Displays the calculated value of the area when, P700 = 2 BS3690 flumes<br />

and P700 = 4 Area Velocity.<br />

P721 Cv<br />

Displays the calculated value for Cv when, P700 = 2 BS3680 flumes.<br />

P722 Cd<br />

Displays the calculated value for Cd when, P700 = 2 BS3680flumes.<br />

P723 Ce<br />

Displays the calculated value for Ce when, P700 = 3 BS3680 weirs.<br />

P724 Cu<br />

Displays the calculated value for Cu when, P700 = 2 BS3680 flume and<br />

P701 = 3 or 4 U-Throated flume.<br />

P725 Kb<br />

Displays the calculated value for Kb when, P700 = 3 BS3680 weirs and<br />

P701 = 1 Rectangular weir.<br />