P717 Exponent<br />

This parameter is used to enter the exponent value when:<br />

P700 PMD Type = 1 Exponent and P701 Primary M.D = 7 Others.<br />

P718 K Factor<br />

This parameter is used to enter the K Factor when:<br />

P700 PMD Type = 1 Exponent and P702 Calculation = 1 Absolute see table<br />

below for further details.<br />

Primary Measuring Device P718 K<br />

Factor<br />

P700 = 1 Exponent<br />

P701 = 1 Supp. Rectangular Weir<br />

Automatically<br />

Calculated<br />

P700 = 1 Exponent<br />

P701 = 2 Trapezod Weir<br />

Automatically<br />

Calculated<br />

P700 = 1 Exponent<br />

P701 = 3 Venturi Flume<br />

Obtain value<br />

and enter<br />

P700 = 1 Exponent<br />

P701 = 4 Parshall Flume<br />

Automatically<br />

Calculated<br />

P700 = 1 Exponent<br />

P701 = 5 Leopald Lagco Flume<br />

Automatically<br />

Calculated<br />

P700 = 1 Exponent<br />

P701 = 6 V Notch<br />

Automatically<br />

Calculated<br />

P700 = 1 Exponent<br />

P701 = 7 Other<br />

Obtain value<br />

and enter<br />

P719 Throat Width<br />

This parameter is used to select the Throat Width of the flume when:<br />

P700 PMD Type = 1 Exponent and P701 = 4 Parshall Flume. After selecting<br />

the Throat Width the Exponent P717 and K Factor P 718 will be set<br />

automatically.<br />