Deltabar S PMD70/75 FMD76/77/78
Deltabar S, PMD70, PMD75, FMD76, FMD77, FMD78 - from AoteWell
Deltabar S, PMD70, PMD75, FMD76, FMD77, FMD78 - from AoteWell
- No tags were found...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
www.aotewell.com www.fa-market.com info@aotewell.com<br />
<strong>Deltabar</strong> S<br />
FMD<strong>77</strong> (continued) 90 Fill fluid:<br />
A<br />
D<br />
L<br />
V<br />
F<br />
Silicone oil<br />
Vegetable oil<br />
Low-temperature oil<br />
High-temperature oil<br />
Inert oil<br />
100 Additional option 1:<br />
A Not selected<br />
E SIL/IEC 61508 Declaration of Conformity<br />
B Material test certificate for wetted components, inspection certificate as per<br />
EN 10204 3.1 acc. to specification 52005<strong>75</strong>9<br />
C NACE MR01<strong>75</strong> (wetted parts)<br />
D Material test certificate for wetted components as per EN 10204 3.1 and<br />
NACE MR01<strong>75</strong> material, inspection certificate as per EN 10204 acc. to<br />
specification 52010806<br />
M Overvoltage protection<br />
J Software setting, see additional spec.<br />
Min alarm current<br />
HART burst mode PV<br />
Min alarm current + HART burst mode PV<br />
N HistoROM/M-DAT<br />
2 Test report acc. to EN 10204 2.2<br />
3 Routine test with certificate, inspection certificate as per EN 10204 3.1<br />
4 Overpressure test with certificate,<br />
inspection certificate as per EN 10204 3.1<br />
110 Additional option 2:<br />
A Not selected<br />
E SIL/IEC 61508 Declaration of Conformity<br />
G Separate housing, cable length see additional spec. + mounting<br />
bracket,<br />
wall/pipe, 316L<br />
(FM/CSA IS: for Div. 1 installation only)<br />
M Overvoltage protection<br />
J Software setting, see additional spec.<br />
Min alarm current<br />
HART burst mode PV<br />
Min alarm current + HART burst mode PV<br />
N HistoROM/M-DAT<br />
R Screws 7/16 UNF, length 1 1/2" (4 pieces) for oval flange adapter PZO<br />
2 Test report acc. to EN 10204 2.2<br />
3 Routine test with certificate,<br />
inspection certificate as per EN 10204 3.1<br />
4 Overpressure test with certificate,<br />
inspection certificate as per EN 10204 3.1<br />
995 Identification:<br />
Z1 Measuring point (TAG)<br />
Z2 Bus address<br />
FMD<strong>77</strong><br />
complete order code<br />
80 Endress+Hauser<br />
AoteWell International.inc sales@aotewell.com Tel: +852-6563-2160