www.aotewell.com www.fa-market.com info@aotewell.com<br />

<strong>Deltabar</strong> S<br />

Process connections FMD<strong>78</strong><br />

with diaphragm seal<br />

Note!<br />

• The weights of the diaphragm seals are given in the tables. See ä 34 for the weight of the transmitter<br />

and ä 51 for the weight of the housing.<br />

• The following drawings are drawings that illustrate how the system works in principle. In other words, the<br />

dimensions of a diaphragm seal supplied can deviate from the dimensions given in this document.<br />

• With the use of high-temperature oils the design can deviate strongly.<br />

• Some device versions have CRN approval. For a CRN-approved device, a CRN-approved process connection<br />

( ä 69 ff, feature 70 "Process connection") has to be ordered with a CSA approval ( ä 69 ff, feature 10<br />

"Approval"). These devices are fitted with a separate plate bearing the registration number 0F10524.5C.<br />

• Observe the information in the "Planning instructions, diaphragm seal systems" section ä 62 ff.<br />

• For further information please contact your local Endress+Hauser Sales Center.<br />

Diaphragm seal cell structure<br />

b<br />

d M<br />

D<br />

Process connection FMD<strong>78</strong>, material AISI 316L<br />

P01-FMD<strong>78</strong>xxx-06-09-xx-xx-000<br />

Flange<br />

Diaphragm seal<br />

Version<br />

Nominal<br />

diameter<br />

Nominal<br />

pressure 1<br />

Max.<br />

diameter<br />

Thickness<br />

Max. diameter of<br />

the process<br />

isolating<br />

diaphragm<br />

Weight of two<br />

diaphragm<br />

seals<br />

D b d M<br />

[mm] [mm] [mm] [kg]<br />

UF DN 50 PN 16-400 102 20 59 2.6<br />

UH DN 80 PN 16-400 138 20 89 4.6<br />

UJ DN 100 PN 16-400 162 20 89 6.2<br />

Flange<br />

Diaphragm seal<br />

Version<br />

Nominal<br />

diameter<br />

Nominal<br />

pressure 1<br />

Max.<br />

diameter<br />

Thickness<br />

Max. diameter of<br />

the process<br />

isolating<br />

diaphragm<br />

Weight of two<br />

diaphragm<br />

seals<br />

D b d M<br />

[in] [lb/sq.in] [in (mm)] [in (mm)] [in (mm)] [kg]<br />

VF 2 150-2500 4.01 (102) 0.79 (20) 2.32 (59) 2.6<br />

VH 3 150-2500 5.35 (136) 0.79 (20) 3.50 (89) 4.6<br />

VJ 4 150-2500 6.22 (158) 0.79 (20) 3.50 (89) 6.2<br />

1) The specified nominal pressure applies to the diaphragm seal. The maximum pressure for the measuring device is<br />

dependent on the lowest-rated element, with regard to pressure, of the selected components. See also ä 30,<br />

"Pressure specifications" section.<br />

44 Endress+Hauser<br />

AoteWell International.inc sales@aotewell.com Tel: +852-6563-2160