www.aotewell.com www.fa-market.com info@aotewell.com<br />

<strong>Deltabar</strong> S<br />

Oxygen applications<br />

Oxygen and other gases can react explosively to oils, grease and plastics, such that, among other things, the<br />

following precautions must be taken:<br />

– All components of the system, such as measuring devices, must be cleaned in accordance with the BAM<br />

(DIN 19247) requirements.<br />

– Dependent on the materials used, a certain maximum temperature and a maximum pressure for oxygen<br />

applications must not be exceeded.<br />

The devices suitable for gaseous oxygen applications are listed in the following table with the specification p max .<br />

Order code for devices 1 cleaned for<br />

oxygen applications<br />

p max for oxygen applications<br />

T max for oxygen<br />

applications<br />

<strong>PMD70</strong> – * * * ** * * * 2 * *,<br />

Devices with 500 mbar (7.5 psi) or<br />

3000 mbar (45 psi) measuring cell<br />

30 bar (450 psi) 60 °C (140 °F)<br />

<strong>PMD70</strong> – * * * ** * * * 2 * *,<br />

Devices with 25 mbar (0.3<strong>75</strong> psi) or<br />

100 mbar (1.5 psi) measuring cell<br />

PN of the measuring cell<br />

60 °C (140 °F)<br />

PMD<strong>75</strong> – * * * ** * * * K * * 160 bar (2400 psi) 85 °C (185 °F)<br />

PMD<strong>75</strong> – * * * ** * * * 2 * * 160 bar (2400 psi) 60 °C (140 °F)<br />

PMD<strong>75</strong> – * * * ** * * * 3 * * 160 bar (2400 psi) 60 °C (140 °F)<br />

<strong>FMD76</strong> – * * * ** * T * * *,<br />

Devices with 500 mbar (7.5 psi) or<br />

3000 mbar (45 psi) measuring cell<br />

30 bar (450 psi) 60 °C (140 °F)<br />

<strong>FMD76</strong> – * * * ** * T * * *,<br />

Devices with 25 mbar (0.3<strong>75</strong> psi) or<br />

100 mbar (1.5 psi) measuring cell<br />

PN of the measuring cell<br />

60 °C (140 °F)<br />

FMD<strong>77</strong> – * * * ** T * F * * PN of the flange 60 °C (140 °F)<br />

FMD<strong>78</strong> – * * * ** * ** 4 * *<br />

FMD<strong>78</strong> – * * * ** * ** D * *<br />

90 bar (1350 psi) 85 °C (185 °F)<br />

1) Only devices, not accessories or enclosed accessories.<br />

Ultrapure gas applications<br />

Applications with hydrogen<br />

Endress+Hauser also offers devices for special applications, such as ultrapure gas, cleaned from oil and grease.<br />

No special restrictions regarding the process conditions apply to these devices.<br />

ä 69 ff, <strong>PMD70</strong> and PMD<strong>75</strong>: feature 80 "Seal", <strong>FMD76</strong> and FMD<strong>77</strong>: feature 70 "Process connection lowpressure<br />

side, material, seal".<br />

With regard to materials in which hydrogen formation takes place, hydrogen atoms can diffuse through the<br />

metal process isolating diaphragms. This can result in incorrect measurement results.<br />

Endress+Hauser offers process isolating diaphragms with gold-rhodium coating for this application.<br />

ä 73 "Ordering information PMD<strong>75</strong>", ä 79 "Ordering information FMD<strong>77</strong>" or ä 82 "Ordering<br />

information FMD<strong>78</strong>", feature 60 "Process isolating diaphragm material".<br />

Endress+Hauser 27<br />

AoteWell International.inc sales@aotewell.com Tel: +852-6563-2160