<strong>Deltabar</strong> S<br />

Performance characteristics – ceramic process isolating<br />

diaphragms<br />

Reference accuracy –<br />

<strong>PMD70</strong>, <strong>FMD76</strong><br />

The reference accuracy comprises the non-linearity (terminal based), hysteresis and non-reproducibility as per<br />

IEC 60<strong>77</strong>0. The data refer to the calibrated span.<br />

The following applies for the root-extracting characteristic curve: The accuracy data of the <strong>Deltabar</strong> S are taken<br />

into the accuracy calculation of the flow rate with a factor of 0.5.<br />

Measuring cell<br />

% of the set span<br />

25 mbar (0.3<strong>75</strong> psi)<br />

• TD 1:1<br />

• TD > 1:1<br />

=<br />

=<br />

±0.15<br />

±0.15 x TD<br />

100 mbar (1.5 psi)<br />

• TD 1:1 to TD 4:1<br />

•TD > 4:1<br />

=<br />

=<br />

±0.0<strong>75</strong><br />

(0.012 x TD + 0.027)<br />

500 mbar (7.5 psi), 3 bar (45 psi)<br />

• TD 1:1 to TD 15:1<br />

•TD > 15:1<br />

=<br />

=<br />

±0.0<strong>75</strong><br />

(0.0015 x TD + 0.05252)<br />

Platinum version:<br />

100 mbar (1.5 psi), 500 mbar (7.5 psi), 3 bar (45 psi)<br />

•TD 1:1 = ±0.05<br />

Total performance –<br />

<strong>PMD70</strong>, <strong>FMD76</strong><br />

The "Total performance" specification comprises the non-linearity including hysteresis, non-reproducibility, the<br />

thermal change of the zero point as well as the influence of the static pressure (p st = 70 bar (1050 psi)).<br />

All specifications apply to the temperature range –10 to +60 °C (+14 to +140 °F) and a turn down of 1:1.<br />

Measuring cell<br />

% of the set span<br />

500 mbar (7.5 psi) • 0.15<br />

Total error<br />

The total error comprises the long-term stability and the total performance.<br />

All specifications apply to the temperature range –10 to +60 °C (+14 to +140 °F) and a turn down of 1:1.<br />

Measuring cell<br />

% of URL/year<br />

25 mbar (0.3<strong>75</strong> psi), 100 mbar (1.5 psi) • 0.33<br />

500 mbar (7.5 psi), 3 bar (45 psi) • 0.20<br />

Warm-up period –<br />

<strong>PMD70</strong>, <strong>FMD76</strong><br />

Influence of the operating<br />

pressure on zero point and<br />

span – <strong>PMD70</strong>, <strong>FMD76</strong><br />

• 4 to 20 mA HART: < 10 s<br />

• PROFIBUS PA: 6 s<br />

• FOUNDATION Fieldbus: 50 s<br />

Measuring cell<br />

Influence of the operating pressure on the<br />

zero point<br />

Influence of the operating pressure on the<br />

span<br />

25 mbar (0.3<strong>75</strong> psi) 0.7 % of URL/7 bar (105 psi) 0.14 % of URL/7 bar (105 psi)<br />

100 mbar (1.5 psi) 0.1<strong>75</strong> % of URL/70 bar (1050 psi) 0.14 % of URL/70 bar (1050 psi)<br />

500 mbar (7.5 psi) 0.0<strong>75</strong> % of URL/70 bar (1050 psi) 0.14 % of URL/70 bar (1050 psi)<br />

3 bar (45 psi) 0.0<strong>75</strong> % of URL/70 bar (1050 psi) 0.14 % of URL/70 bar (1050 psi)<br />

Note!<br />

The influence of the operating pressure on the zero point can be corrected.<br />

22 Endress+Hauser<br />