06.09.2015 Views

Deltabar S PMD70/75 FMD76/77/78

Deltabar S, PMD70, PMD75, FMD76, FMD77, FMD78 - from AoteWell

Deltabar S, PMD70, PMD75, FMD76, FMD77, FMD78 - from AoteWell

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

www.aotewell.com www.fa-market.com info@aotewell.com<br />

<strong>Deltabar</strong> S<br />

Warm-up period –<br />

PMD<strong>75</strong>, FMD<strong>77</strong>, FMD<strong>78</strong><br />

• 4 to 20 mA HART: < 10 s<br />

• PROFIBUS PA: 6 s<br />

• FOUNDATION Fieldbus: 50 s<br />

Influence of the operating<br />

pressure on zero point and<br />

span – PMD<strong>75</strong>, FMD<strong>77</strong>,<br />

FMD<strong>78</strong><br />

Measuring<br />

cell<br />

AISI 316L/1.4435, Alloy, gold-rhodium coated<br />

or Monel process isolating diaphragm<br />

Influence of the<br />

operating pressure on<br />

the zero point<br />

Influence of the<br />

operating pressure on<br />

the span<br />

Tantalum process isolating diaphragm<br />

Influence of the<br />

operating pressure on<br />

the zero point<br />

Influence of the<br />

operating pressure on<br />

the span<br />

10 mbar<br />

(0.15 psi)<br />

0.15 % of URL/7 bar<br />

(105 psi)<br />

0.035 % of URL/7 bar<br />

(105 psi)<br />

<br />

<br />

30 mbar<br />

(0.45 psi)<br />

0.35 % of URL/70 bar<br />

(1050 psi)<br />

0.14 % of URL/70 bar<br />

(1050 psi)<br />

<br />

<br />

100 mbar<br />

(1.5 psi)<br />

0.15 % of URL/70 bar<br />

(1050 psi)<br />

0.14 % of URL/70 bar<br />

(1050 psi)<br />

0.42 % of URL/70 bar<br />

(1050 psi)<br />

0.42 % of URL/70 bar<br />

(1050 psi)<br />

500 mbar<br />

(7.5 psi)<br />

3 bar<br />

(45 psi)<br />

16 bar<br />

(240 psi)<br />

0.0<strong>75</strong> % of URL/70 bar<br />

(1050 psi)<br />

0.14 % of URL/70 bar<br />

(1050 psi)<br />

0.14 % of URL/70 bar<br />

(1050 psi)<br />

0.14 % of URL/70 bar<br />

(1050 psi)<br />

40 bar<br />

(600 psi)<br />

Note!<br />

The influence of the operating pressure on the zero point can be corrected.<br />

Thermal change of the zero<br />

output and the output span –<br />

PMD<strong>75</strong><br />

Measuring cell<br />

AISI 316L/1.4435, Alloy, gold-rhodium<br />

coated or Monel process isolating<br />

diaphragm<br />

–10 to +60 °C (14 to 140 °F)<br />

% of the set span<br />

Tantalum process isolating diaphragm<br />

10 mbar (0.15 psi),<br />

30 mbar (0.45 psi)<br />

(0.31 x TD + 0.06)<br />

<br />

100 mbar (1.5 psi) (0.18 x TD + 0.02) (0.24 x TD + 0.06)<br />

500 mbar (7.5 psi),<br />

3 bar (45 psi)<br />

(0.08 x TD + 0.05)<br />

16 bar (240 psi) (0.1 x TD + 0.1)<br />

40 bar (600 psi) (0.08 x TD + 0.05)<br />

Measuring cell<br />

–40 to -10 °C (-40 to 14 °F),<br />

+60 to +85 °C (140 to 185 °F)<br />

all process isolating diaphragm materials<br />

% of the set span<br />

10 mbar (0.15 psi),<br />

30 mbar (0.45 psi)<br />

(0.45 x TD + 0.1)<br />

100 mbar (1.5 psi) (0.3 x TD + 0.15)<br />

500 mbar (7.5 psi),<br />

3 bar (45 psi)<br />

(0.12 x TD + 0.1)<br />

16 bar (240 psi) (0.15 x TD + 0.2)<br />

40 bar (600 psi) (0.37 x TD + 0.1)<br />

Endress+Hauser 21<br />

AoteWell International.inc sales@aotewell.com Tel: +852-6563-2160