www.aotewell.com www.fa-market.com info@aotewell.com<br />
<strong>Deltabar</strong> S<br />
Performance characteristics – metal process isolating<br />
diaphragms<br />
Reference accuracy –<br />
PMD<strong>75</strong>, FMD<strong>77</strong>, FMD<strong>78</strong><br />
The reference accuracy comprises the non-linearity (terminal based), hysteresis and non-reproducibility as per<br />
IEC 60<strong>77</strong>0. The data refer to the calibrated span.<br />
The following applies for the root-extracting characteristic curve:<br />
The accuracy data of the <strong>Deltabar</strong> S are taken into the accuracy calculation of the flow rate with a factor of 0.5.<br />
PMD<strong>75</strong><br />
Measuring cell<br />
% of the set span<br />
10 mbar (0.15 psi)<br />
30 mbar (0.45 psi)<br />
• TD 1:1<br />
• TD > 1:1<br />
=<br />
=<br />
±0.15<br />
±0.15 x TD<br />
100 mbar (1.5 psi)<br />
• TD 1:1 to TD 4:1<br />
•TD > 4:1<br />
=<br />
=<br />
±0.0<strong>75</strong><br />
(0.012 x TD + 0.027)<br />
500 mbar (7.5 psi)<br />
• TD 1:1 to TD 15:1<br />
• TD > 15:1<br />
=<br />
=<br />
±0.0<strong>75</strong><br />
(0.0015 x TD + 0.053)<br />
Platinum version:<br />
00 mbar (1.5 psi)<br />
•TD 1:1 = ±0.05<br />
FMD<strong>77</strong>, FMD<strong>78</strong><br />
Measuring cell FMD<strong>77</strong> FMD<strong>78</strong><br />
% of the set span (influence of the diaphragm seal included)<br />
100 mbar (1.5 psi)<br />
• TD 1:1 to TD 4:1<br />
• TD > 4:1<br />
= ±0.15<br />
= (0.03 x TD + 0.03)<br />
• TD 1:1 to TD 4:1<br />
• TD > 4:1<br />
= ±0.15<br />
= (0.03 x TD + 0.03)<br />
500 mbar<br />
(7.5 psi)<br />
3 bar (45 psi)<br />
16 bar (240 psi)<br />
• TD 1:1 to TD 15:1<br />
•TD > 15:1<br />
= ±0.0<strong>75</strong><br />
= (0.0015 x TD + 0.053)<br />
• TD 1:1 to TD 4:1<br />
•TD > 4:1<br />
= ±0.15<br />
= (0.02 x TD + 0.07)<br />
40 bar (600 psi) <br />
• TD 1:1 to TD 4:1<br />
•TD > 4:1<br />
= ±0.15<br />
= (0.02 x TD + 0.07)<br />
Total performance – PMD<strong>75</strong><br />
The "Total performance" specification comprises the non-linearity including hysteresis, non-reproducibility, the<br />
thermal change of the zero point as well as the influence of the static pressure (p st = 70 bar (1050 psi)).<br />
All specifications apply to the temperature range –10 to +60 °C (+14 to +140 °F).<br />
Measuring cell<br />
AISI 316L/1.4435, Alloy, gold-rhodium or<br />
Monel process isolating diaphragm<br />
Tantalum process isolating diaphragm<br />
% of the set span<br />
500 mbar<br />
(7.5 psi) to TD 2:1<br />
0.15 0.30<br />
Total error<br />
The total error comprises the long-term stability and the total performance.<br />
All specifications apply to the temperature range –10 to +60 °C (+14 to +140 °F) and a turn down of 1:1.<br />
Measuring cell<br />
AISI 316L/1.4435, Alloy, gold-rhodium or<br />
Monel process isolating diaphragm<br />
Tantalum process isolating diaphragm<br />
% of URL/year<br />
10 mbar (0.15 psi)<br />
30 mbar (0.45 psi)<br />
0.33 <br />
100 mbar (1.5 psi) 0.33 0.48<br />
500 mbar (7.5 psi) 0.20 0.35<br />
20 Endress+Hauser<br />
AoteWell International.inc sales@aotewell.com Tel: +852-6563-2160