Task Order HSCG23-09-J-ARP268 A00001

Task Order HSCG23-09-J-ARP268 A00001

Task Order HSCG23-09-J-ARP268 A00001

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

OMB Approval 2700-0042<br />

1. CONTRACT ID CODE PAGE OF PAGES<br />

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1 5<br />

2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable)<br />

<strong>A00001</strong> See BLK 16 <strong>HSCG23</strong>-06-D-ARB001 RB-M<br />

6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE<br />

Administrative Contracting Office<br />

1600 Ely Street<br />

Marinette WI. 54143-2434<br />

Vicki.A.Smith@uscg.mil<br />

8. NAME AND ADDRESS OF CONTRACTOR (No. Street, county, State and ZIP: Code) () 9A. AMENDMENT OF SOLICITATION NO.<br />

N/A<br />

9B. DATED (SEE ITEM 11)<br />

Marinette Marine Corporation, Inc.<br />

1600 Ely Street<br />

Marinette, WI 54143<br />

DUNS #00-613-5388 X <strong>HSCG23</strong>-06-D-ARB001<br />

<strong>HSCG23</strong>-<strong>09</strong>-J-<strong>ARP268</strong><br />

10B. DATED (SEE ITEM 13)<br />

CODE FACILITY CODE 21JUN2006<br />

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS<br />

10A. MODIFICATION OF CONTRACT/ORDER NO.<br />

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended, is not extended.<br />

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:<br />

(a) By completing Items 8 and 15, and returning one (1) copy of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;<br />

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE<br />

RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATA SPECIFIED MAY RESULT IN REJECTION OF<br />

YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each<br />

telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and data specified.<br />

12. ACCOUNTING AND APPROPRIATION DATA (If required) N/A<br />

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,<br />

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.<br />

() A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.<br />

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET<br />

FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).<br />

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:<br />

X D.<br />

OTHER Specify type of modification and authority)<br />

52.243-3 Changes – Time-and-Materials or Labor-Hours (Sept 2000)<br />

E. IMPORTANT: Contractor is not, is required to sign this document and return 1 copy to the issuing office.<br />

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)<br />

This Modification to <strong>Task</strong> <strong>Order</strong> <strong>HSCG23</strong>-<strong>09</strong>-J-<strong>ARP268</strong> incorporates revised scope of work.<br />

Reference Direction to Proceed (DTP) dated July 2, 20<strong>09</strong>.<br />

(CONTINUED ON NEXT PAGE)<br />

Except at provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.<br />

15A. NAME AND TITLE OF SIGNER (Type or print) 16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)<br />

VICKI A. SMITH, ADMINISTRATIVE CONTRACTING OFFICER<br />

15B. CONTRACTOR/OFFEROR 15C. DATE SIGNED 16B. UNITED STATES OF AMERICA 16C. DATE SIGNED<br />

NSN 7540-01-152-8070 30-105 STANDARD FORM 30 (REV. 10-83)<br />

PREVIOUS EDITION UNUSABLE Computer Generated Prescribed by GSA<br />

FAR (48 CFR) 53.243


1. The revised scope of work tasked by the Administrative Contracting Officer’s e-mail dated<br />

July 2, 20<strong>09</strong> is hereby formally incorporated into the <strong>Task</strong> <strong>Order</strong>. This Modification transfers a<br />

portion of the effort from CLIN 3007 to CLIN 4007 to allow MMC to invoice for the added work<br />

at Price Period 4 labor rates.<br />

2. Optional Form 347, part 17(b), Supplies or Services, is hereby modified to read as follows:<br />

This <strong>Task</strong> <strong>Order</strong>, under IDIQ Contract <strong>HSCG23</strong>-06-D-ARB001, establishes a time period and<br />

Not-to-Exceed (NTE) value for Engine Room Intake Ventilation Baffle Prototype and Testing on<br />

Hull 45602 and 45613 in accordance with the attached revised Scope of Work.<br />

The total NTE amount for this order remains at $12,000.<br />

Time and Materials CLIN 3007, Technical Services NTE amount is hereby changed from<br />

$12,000 to $6,000.<br />

Time and Materials CLIN 4007, Technical Services NTE amount is hereby added in the amount<br />

of $6,000.<br />

After the establishment of final costs under this <strong>Task</strong> <strong>Order</strong>, a Modification will be issued to<br />

deobligate excess funds.<br />

Period of Performance is 8 June 20<strong>09</strong> – 30 September 20<strong>09</strong>.<br />

3. All other terms and conditions of the <strong>Task</strong> <strong>Order</strong> remain unchanged.<br />

<strong>A00001</strong> Page 2 of 5


Amended Scope of Work for Technical Services under CLIN 3007 and 4007<br />

<strong>Task</strong> <strong>Order</strong><br />

<strong>HSCG23</strong>-<strong>09</strong>-J-<strong>ARP268</strong><br />

Hull 45602 and 45613 Engine Room Intake Ventilation Baffle<br />

1.0 Background:<br />

1.1 Operational Testing and Evaluation (OT&E) of the RB-M has indicated<br />

that water intrusion into the Engine Room may occur through the intake<br />

demisters. Intrusion has been observed to occur through routine cleaning<br />

of demisters with fresh water hoses as well as in conditions of following<br />

seas when green water has been taken over the stern.<br />

1.2 The Government has developed a baffle concept that is approximately 5”<br />

high to capture any water that intrudes past the intake demisters prior to<br />

making it into the ducting on the RB-M. Photographs of the area and a<br />

concept design of this baffle have been provided as enclosure (1).<br />

1.3 The Government requests that the Contractor perform engineering design<br />

services to validate the baffle concept, recommend specific design<br />

configuration, and incorporate the baffle as a prototype on Hull 45602 in<br />

order to test any effect on engine performance.<br />

1.4 For any vendor support the Contractor intends to obtain as a material cost<br />

estimated to exceed $500 under this order, aside from prototype materials,<br />

Engine Original Equipment Manufacturer (OEM) performance testing,<br />

and Gas free testing for welding the Contractor shall obtain Contracting<br />

Officer’s approval in advance of the purchase.<br />

2.0 Requirements: The Contractor shall evaluate the prototype in the following methods.<br />

2.1 Technical Evaluation of Concept: The Contractor shall evaluate the<br />

concept design of this baffle to determine whether the height of the baffle<br />

will result in any adverse effects on engine performance.<br />

Recommendations to improve performance, such as increased height or<br />

fwd location shall be provided.<br />

2.2 Technical Design Review – At least 3 business days prior to the<br />

installation, a technical design review shall occur to present the baffle<br />

prototype design and available revised calculations. The review shall<br />

finalize Government and Contractor expectations of prototype baffle<br />

installation and testing.<br />

2.2.1 [<strong>A00001</strong>] Installation of the Baffle Prototype on Hull 45602: The<br />

Contractor shall install the prototype baffle on Hull 45602 during<br />

an upcoming availability<br />

<strong>A00001</strong><br />

Page 3 of 5


Amended Scope of Work for Technical Services under CLIN 3007 and 4007<br />

<strong>Task</strong> <strong>Order</strong><br />

<strong>HSCG23</strong>-<strong>09</strong>-J-<strong>ARP268</strong><br />

2.2.2 The prototype shall be installed in accordance with all relevant<br />

requirements of the RB-M Production Contract, <strong>HSCG23</strong>-06-D-<br />

ARB001.<br />

2.2.3 Engine performance prior and after installation of the baffle will be<br />

tested to ensure engine performance is not significantly altered.<br />

Engine OEM representatives shall be present to perform these tests<br />

prior to and after baffle prototype installation to certify the engine<br />

performance.<br />

2.2.4 Air velocity at engine room side of the intake will be measured and<br />

recorded at 10 speeds to include idle, cruise speed (30 kts), and<br />

Max speed (42.5+ Kts) both prior to and after the installation of the<br />

baffle. Engine RPM shall be recorded for each speed.<br />

2.2.5 Engine room/Atmospheric differential pressure shall be measured<br />

and recorded with a manometer at 10 speeds to include idle, cruise<br />

speed (30 kts), and Max speed (42.5+ Kts) both prior to and after<br />

the installation of the baffle. Engine RPM will be recorded for each<br />

speed.<br />

2.3 [<strong>A00001</strong>] Installation of the Baffle Prototype on Hull 45613: The<br />

Contractor shall install the prototype baffle on Hull 45613 prior to<br />

Post-Construction Inspection.<br />

2.3.1 The prototype shall be installed in accordance with all relevant<br />

requirements of the RB-M Production Contract, <strong>HSCG23</strong>-06-<br />

D-ARB001.<br />

2.3.2 No additional testing shall be conducted on 45613. Engine<br />

performance data obtained during normal pre-delivery testing<br />

and trials shall be compared against the 45602 test results to<br />

verify prototype effectiveness.<br />

2.4 If the prototype baffle limits the performance of the engines resulting in<br />

failed OEM performance tests, the prototype shall be removed. All<br />

disturbed surfaces shall be returned to pre-installation conditions. This<br />

work shall be covered under a separate task order.<br />

2.5 Evaluation of Results – The Contractor shall present results of the<br />

prototype to the Government for evaluation within one week of<br />

completion of testing. The report shall document:<br />

2.5.1 The as-built configuration of the prototype using appropriate<br />

sketches and photographs.<br />

2.5.2 Engine performance evaluation testing prior to and after the install<br />

<strong>A00001</strong><br />

Page 4 of 5


Amended Scope of Work for Technical Services under CLIN 3007 and 4007<br />

<strong>Task</strong> <strong>Order</strong><br />

<strong>HSCG23</strong>-<strong>09</strong>-J-<strong>ARP268</strong><br />

2.5.3 Data Table and plot of Engine Room Intake Air Velocity vs<br />

Engine RPM before and after install of baffle. RB-M speed and<br />

supply CFM shall also be presented in the table and the plot.<br />

2.5.4 Data Table and plot of differential pressure vs Engine RPM before<br />

and after install of baffle. RB-M speed shall also be presented in<br />

the plot.<br />

2.5.5 Data and Plots shall be available in Excel Format.<br />

2.5.6 The Government reviewed the Engine Room Ventilation<br />

Calculations (45RBM-514-003) submitted under CDRL 085-004<br />

as part of this prototype effort and identified areas that require<br />

revision. These issues are presented as Encl. (2) and were<br />

presented to MMC during an April 22 nd meeting and marked up<br />

spreadsheets were provided to the Contractor via email after the<br />

discussion.<br />

<strong>A00001</strong><br />

Page 5 of 5


FREV<br />

8 7 6 5 4 3 2 1<br />

F<br />

E<br />

E<br />

D<br />

D<br />

ISOMETRIC VIEW<br />

C<br />

C<br />

B<br />

A<br />

DEngine Room Intake<br />

B<br />

A<br />

PLAN VIEW<br />

SCALE 1:20<br />

UNLESS OTHERWISE SPECIFIED:<br />

DIMENSIONS ARE IN INCHES<br />

TOLERANCES:<br />

FRACTIONAL<br />

ANGULAR: MACH BEND<br />

TWO PLACE DECIMAL<br />

THREE PLACE DECIMAL<br />

DRAWN<br />

CHECKED<br />

ENG APPR.<br />

MFG APPR.<br />

NAME<br />

DATE<br />

TITLE:<br />

A<br />

PROPRIETARY AND CONFIDENTIAL<br />

THE INFORMATION CONTAINED IN THIS<br />

DRAWING IS THE SOLE PROPERTY OF<br />

. ANY<br />

REPRODUCTION IN PART OR AS A WHOLE<br />

WITHOUT THE WRITTEN PERMISSION OF<br />

IS<br />

PROHIBITED.<br />

NEXT ASSY<br />

USED ON<br />

APPLICATION<br />

INTERPRET GEOMETRIC<br />

TOLERANCING PER:<br />

MATERIAL<br />

FINISH<br />

Q.A.<br />

COMMENTS:<br />

SIZE<br />

D<br />

DWG. NO.<br />

SCALE: 1:100WEIGHT:<br />

REV<br />

SHEET 1 OF 3<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1


FREV<br />

8 7 6 5 4 3 2 1<br />

F<br />

E<br />

DECK OPENING<br />

13 1/2"<br />

E<br />

9"<br />

B<br />

B<br />

12"<br />

D<br />

29 1/2"<br />

12 3/8"<br />

D<br />

13 5/8"<br />

C<br />

C<br />

B<br />

DETAIL A<br />

SCALE 1 : 5<br />

DEngine Room Intake<br />

B<br />

SECTION B-B<br />

SCALE 1 : 5<br />

A<br />

UNLESS OTHERWISE SPECIFIED:<br />

DIMENSIONS ARE IN INCHES<br />

TOLERANCES:<br />

FRACTIONAL<br />

ANGULAR: MACH BEND<br />

TWO PLACE DECIMAL<br />

THREE PLACE DECIMAL<br />

DRAWN<br />

CHECKED<br />

ENG APPR.<br />

MFG APPR.<br />

NAME<br />

DATE<br />

TITLE:<br />

A<br />

PROPRIETARY AND CONFIDENTIAL<br />

THE INFORMATION CONTAINED IN THIS<br />

DRAWING IS THE SOLE PROPERTY OF<br />

. ANY<br />

REPRODUCTION IN PART OR AS A WHOLE<br />

WITHOUT THE WRITTEN PERMISSION OF<br />

IS<br />

PROHIBITED.<br />

NEXT ASSY<br />

USED ON<br />

APPLICATION<br />

INTERPRET GEOMETRIC<br />

TOLERANCING PER:<br />

MATERIAL<br />

FINISH<br />

Q.A.<br />

COMMENTS:<br />

SIZE<br />

D<br />

DWG. NO.<br />

SCALE: 1:200WEIGHT:<br />

REV<br />

SHEET 2 OF 3<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1


29 7/8"<br />

1 1/8"<br />

R1/4"<br />

FREV<br />

8 7 6 5 4 3 2 1<br />

F<br />

E<br />

E<br />

D<br />

5"<br />

86.80°<br />

6 5/8"<br />

Isometric View of Baffle<br />

D<br />

Elevation View of Baffle<br />

1"<br />

C<br />

Side View of Baffle<br />

C<br />

B<br />

3"<br />

5/8"<br />

DEngine Room Intake<br />

B<br />

Bottom View of Baffle<br />

A<br />

UNLESS OTHERWISE SPECIFIED:<br />

DIMENSIONS ARE IN INCHES<br />

TOLERANCES:<br />

FRACTIONAL<br />

ANGULAR: MACH BEND<br />

TWO PLACE DECIMAL<br />

THREE PLACE DECIMAL<br />

DRAWN<br />

CHECKED<br />

ENG APPR.<br />

MFG APPR.<br />

NAME<br />

DATE<br />

TITLE:<br />

A<br />

PROPRIETARY AND CONFIDENTIAL<br />

THE INFORMATION CONTAINED IN THIS<br />

DRAWING IS THE SOLE PROPERTY OF<br />

. ANY<br />

REPRODUCTION IN PART OR AS A WHOLE<br />

WITHOUT THE WRITTEN PERMISSION OF<br />

IS<br />

PROHIBITED.<br />

NEXT ASSY<br />

USED ON<br />

APPLICATION<br />

INTERPRET GEOMETRIC<br />

TOLERANCING PER:<br />

MATERIAL<br />

FINISH<br />

Q.A.<br />

COMMENTS:<br />

SIZE<br />

D<br />

SCALE: 1:2<br />

DWG. NO.<br />

WEIGHT:<br />

REV<br />

SHEET 3 OF 3<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1